Experimental study of high strength concrete-filled circular tubular columns under eccentric loading

被引:126
作者
Portoles, J. M. [2 ]
Romero, M. L. [1 ]
Bonet, J. L. [1 ]
Filippou, F. C. [3 ]
机构
[1] Univ Politecn Valencia, Inst Ciencia & Tecnol Hormigon ICITECH, Valencia, Spain
[2] Univ Jaume 1, Dept Mech Engn & Construct, Castellon de La Plana, Spain
[3] Univ Calif Berkeley, Dept Civil & Environm Engn, Berkeley, CA 94720 USA
关键词
Composite column; Concrete-filled tubular columns; High strength concrete; Buckling; OF-THE-ART; EXPERIMENTAL BEHAVIOR; STEEL; CAPACITY;
D O I
10.1016/j.jcsr.2010.11.017
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The paper describes 37 tests conducted on slender circular tubular columns filled with normal and high strength concrete subjected to eccentric axial load. The test parameters were the nominal strength of concrete (30, 70 and 90 MPa), the diameter to thickness ratio D/t, the eccentricity ratio e/D and the column slenderness (L/D). The experimental ultimate load of each test was compared with the design loads from Eurocode 4, which limits the strength of concrete up to 50 MPa. The aim of the paper is to establish the advisability of the use of high strength concretes as opposed to that of normal strength concretes by comparing three performance indices: concrete contribution ratio, strength index and ductility index. The results show for the limited cases analyzed that the use of high strength concrete for slender composite columns is interesting since this achieves ductile behavior despite the increase in load-carrying capacity is not greatly enhanced. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:623 / 633
页数:11
相关论文
共 50 条
  • [21] Fire behavior of axially loaded slender high strength concrete-filled tubular columns
    Romero, Manuel L.
    Moliner, V.
    Espinos, A.
    Ibanez, C.
    Hospitaler, A.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2011, 67 (12) : 1953 - 1965
  • [22] Tests and numerical behavior of circular concrete-filled double skin steel tubular stub columns under eccentric loads
    Manigandan, R.
    Kumar, Manoj
    STRUCTURAL ENGINEERING AND MECHANICS, 2023, 88 (03) : 287 - 299
  • [23] Experimental assessment on the size effects of circular concrete-filled steel tubular columns under axial compression
    Liu, Jiepeng
    Gao, Pan
    Lin, Xuchuan
    Wang, Xuanding
    Zhou, Xuhong
    Chen, Y. Frank
    ENGINEERING STRUCTURES, 2023, 275
  • [24] A COMPARATIVE STUDY ON SQUARE AND CIRCULAR HIGH STRENGTH CONCRETE-FILLED STEEL TUBE COLUMNS
    Guler, S.
    Copur, A.
    Aydogan, M.
    ADVANCED STEEL CONSTRUCTION, 2014, 10 (02): : 234 - 247
  • [25] EXPERIMENTAL BEHAVIOR OF HIGH STRENGTH CONCRETE-FILLED SQUARE STEEL TUBE UNDER BI-AXIAL ECCENTRIC LOADING
    Li, GuoChang
    Yang, Zhijian
    Lang, Yan
    ADVANCED STEEL CONSTRUCTION, 2010, 6 (04): : 963 - 975
  • [26] Analytical buckling of slender circular concrete-filled steel tubular columns with compliant interfaces
    Schnabl, S.
    Jelenic, G.
    Planinc, I.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2015, 115 : 252 - 262
  • [27] Influence of Slenderness on High-Strength Rectangular Concrete-Filled Tubular Columns with Axial Load and Nonconstant Bending Moment
    Hernandez-Figueirido, D.
    Romero, M. L.
    Bonet, J. L.
    Montalva, J. M.
    JOURNAL OF STRUCTURAL ENGINEERING, 2012, 138 (12) : 1436 - 1445
  • [28] Strength of rectangular concrete-filled tubular beam-columns
    Liu Dalin
    Gho Wie-Min
    8TH INTERNATIONAL CONFERENCE ON STEEL-CONCRETE COMPOSITE AND HYBRID STRUCTURES, PROCEEDINGS, 2006, : 91 - 97
  • [29] Circular and square slender concrete-filled tubular columns under large eccentricities and fire
    Espinos, A.
    Romero, M. L.
    Serra, E.
    Hospitaler, A.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2015, 110 : 90 - 100
  • [30] Numerical analysis of axially loaded circular high strength concrete-filled double steel tubular short columns
    Ahmed, Mizan
    Liang, Qing Quan
    Patel, Vipulkumar Ishvarbhai
    Hadi, Muhammad N. S.
    THIN-WALLED STRUCTURES, 2019, 138 : 105 - 116