Experimental study of high strength concrete-filled circular tubular columns under eccentric loading

被引:131
作者
Portoles, J. M. [2 ]
Romero, M. L. [1 ]
Bonet, J. L. [1 ]
Filippou, F. C. [3 ]
机构
[1] Univ Politecn Valencia, Inst Ciencia & Tecnol Hormigon ICITECH, Valencia, Spain
[2] Univ Jaume 1, Dept Mech Engn & Construct, Castellon de La Plana, Spain
[3] Univ Calif Berkeley, Dept Civil & Environm Engn, Berkeley, CA 94720 USA
关键词
Composite column; Concrete-filled tubular columns; High strength concrete; Buckling; OF-THE-ART; EXPERIMENTAL BEHAVIOR; STEEL; CAPACITY;
D O I
10.1016/j.jcsr.2010.11.017
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The paper describes 37 tests conducted on slender circular tubular columns filled with normal and high strength concrete subjected to eccentric axial load. The test parameters were the nominal strength of concrete (30, 70 and 90 MPa), the diameter to thickness ratio D/t, the eccentricity ratio e/D and the column slenderness (L/D). The experimental ultimate load of each test was compared with the design loads from Eurocode 4, which limits the strength of concrete up to 50 MPa. The aim of the paper is to establish the advisability of the use of high strength concretes as opposed to that of normal strength concretes by comparing three performance indices: concrete contribution ratio, strength index and ductility index. The results show for the limited cases analyzed that the use of high strength concrete for slender composite columns is interesting since this achieves ductile behavior despite the increase in load-carrying capacity is not greatly enhanced. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:623 / 633
页数:11
相关论文
共 23 条
[1]  
BERGMANN R, 1994, P 6 INT S TUB STRUCT
[2]  
CIDECT, 1979, CIDECT MON
[3]  
CIDECT, 1970, CIDECT MON
[4]  
*EUR COMM STAND, 2004, 1994112004 EN EUR CO
[5]   Behavior of eccentrically loaded concrete-filled steel tubular columns [J].
Fujimoto, T ;
Mukai, A ;
Nishiyama, I ;
Sakino, K .
JOURNAL OF STRUCTURAL ENGINEERING, 2004, 130 (02) :203-212
[6]   Axial capacity of circular concrete-filled tube columns [J].
Giakoumelis, G ;
Lam, D .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2004, 60 (07) :1049-1068
[7]  
Goode C.D., 2008, STRUCTURAL ENG, V86, P33
[8]  
Gourley BC, 2008, UILUENG20081802 DEP
[9]  
Grauers M., 1993, COMPOSITE COLUMNS HO
[10]  
Han L.H., 2000, Advances in Structural Engineering, V3, P337, DOI DOI 10.1260/1369433001502265