Investigation on heat exchanger arrangement in solar enhanced natural draft dry cooling towers under various crosswind conditions

被引:15
作者
Xu, Mengfei [1 ]
He, Suoying [1 ]
Cheng, Jun [2 ]
Gao, Ming [1 ]
Lu, Yuanshen [3 ]
Hooman, Kamel [3 ]
Xu, Yi [1 ]
Geng, Zhe [4 ]
Zhang, Shuzhen [4 ]
机构
[1] Shandong Univ, Sch Energy & Power Engn, Shandong Engn Lab High Efficiency Energy Conserva, Jinan 250061, Shandong, Peoples R China
[2] Zhejiang Univ, State Key Lab Clean Energy Utilizat, Hangzhou 310027, Peoples R China
[3] Univ Queensland, Sch Mech & Min Engn, St Lucia, Qld 4072, Australia
[4] Shandong Hetong Informat Technol CO LTD, Jinan 250013, Shandong, Peoples R China
关键词
Solar enhanced natural draft dry cooling towers; Heat exchanger; Circular arrangement; Sawtooth arrangement; NUMERICAL-SIMULATION; PERFORMANCE ENHANCEMENT; THERMAL PERFORMANCE; WETTED MEDIA; OPTIMIZATION; DESIGN; FLOW; SYSTEM; LIMITATIONS;
D O I
10.1016/j.csite.2021.101505
中图分类号
O414.1 [热力学];
学科分类号
摘要
Solar enhanced natural draft dry cooling tower (SENDDCT) is a novel heat rejection device for thermal power plant, which uses solar energy to reheat the air after the heat exchanger and therefore improves the ventilation of the tower for performance enhancement. This paper develops 3-D models to compare the effects of circular/sawtooth arrangements of heat exchanger on cooling performance of a 140 m high SENDDCT. The result shows that sawtooth arrangement can improve the ventilation and heat dissipation rate of SENDDCTs. Under no crosswind condition, the flow field distributions of sawtooth and circular arrangements are similar in the tower. The ventilation and heat dissipation rate of sawtooth arrangement increases by 34.0 % and 46.8 % respectively when compared with circular arrangement under no crosswind condition. Under crosswind condition, the flow field of sawtooth arrangement is less affected by crosswind than that of circular arrangement. The ventilation rate and heat dissipation rate of sawtooth arrangement increases by 38.5 % and 65.0 % respectively when compared with circular arrangement at crosswind speed of 3 m/s. This study verifies that the sawtooth arrangement can weaken the crosswind effect and improve the cooling performance of SENDDCT and provides guidance for the optimal arrangement of heat exchanger for the SENDDCT.
引用
收藏
页数:17
相关论文
共 45 条
[1]   Experimental investigation on thermal performance of natural draft wet cooling towers employing an innovative wind-creator setup [J].
Alavi, Seyed Rashid ;
Rahmati, Mehdi .
ENERGY CONVERSION AND MANAGEMENT, 2016, 122 :504-514
[2]   Cooling towers performance in a changing climate: Techno-economic modeling and design optimization [J].
Ayoub, Ali ;
Gjorgiev, Blaze ;
Sansavini, Giovanni .
ENERGY, 2018, 160 :1133-1143
[3]   Thermal and technical analyses of solar chimneys [J].
Bernardes, MAD ;
Voss, A ;
Weinrebe, G .
SOLAR ENERGY, 2003, 75 (06) :511-524
[4]   3E (Energy-Exergy-Economic) comparative study of integrating wet and dry cooling systems in solar tower power plants [J].
Boukelia, T. E. ;
Bouraoui, A. ;
Laouafi, A. ;
Djimli, S. ;
Kabar, Y. .
ENERGY, 2020, 200
[5]   Numerical study regarding cooling capacity for non-equidistant fillings in large-scale wet cooling towers [J].
Chen, Rui ;
Zhang, Deying ;
Zhang, Zhengqing ;
Han, Qiang ;
He, Suoying ;
Gao, Ming .
CASE STUDIES IN THERMAL ENGINEERING, 2021, 26 (26)
[6]  
[范皓龙 Fan Haolong], 2017, [太阳能学报, Acta Energiae Solaris Sinica], V38, P826
[7]   Influence of non-uniform layout fillings on thermal performance for wet cooling tower [J].
Gao, Ming ;
Zhang, Lei ;
Wang, Ni-ni ;
Shi, Yue-tao ;
Sun, Feng-zhong .
APPLIED THERMAL ENGINEERING, 2016, 93 :549-555
[8]   Thermal characteristics of dry cooling tower reconstructed from obsolete natural draft wet cooling tower and the relevant thermal system coupling optimization [J].
Ge, Wenjing ;
Zhao, Yuanbin ;
Song, Shiwei ;
Li, Wendong ;
Gao, Shasha ;
Chen, TieFeng .
APPLIED THERMAL ENGINEERING, 2020, 174
[9]   A comprehensive analysis of a laboratory scale counter flow wet cooling tower using the first and the second laws of thermodynamics [J].
Ghazani, Mehran Akbarpour ;
Hashem-ol-Hosseini, Alireza ;
Emami, Mohsen Davazdah .
APPLIED THERMAL ENGINEERING, 2017, 125 :1389-1401
[10]   Wind tunnel test on the flow resistance of U-type water collecting devices for natural draft wet cooling towers [J].
He, Suoying ;
Zhang, Guanhong ;
Gao, Ming ;
Sun, Fengzhong ;
Huang, Xiang .
JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2019, 186 :234-240