Extended depth-of-field microscopic imaging with a variable focus microscope objective

被引:107
作者
Liu, Sheng [1 ]
Hua, Hong [1 ]
机构
[1] Univ Arizona, Visualizat & Imaging Syst Lab 3 D, Coll Opt Sci, Tucson, AZ 85721 USA
基金
美国国家科学基金会;
关键词
LIQUID LENS; DECONVOLUTION; DEEP;
D O I
10.1364/OE.19.000353
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Increasing the depth-of-field (DOF) while maintaining high resolution imaging has been a classical challenge for conventional microscopes. Extended DOF (EDOF) is especially essential for imaging thick specimens. We present a microscope capable of capturing EDOF images in a single shot. A volumetric optical sampling method is applied by rapidly scanning the focus of a vari-focal microscope objective throughout the extended depths of a thick specimen within the duration of a single detector exposure. An EDOF image is reconstructed by deconvolving the captured image with the response function of the system. Design of a vari-focal objective and algorithms for restoring EDOF images are presented. Proof-of-concept experimental results demonstrate significantly extended DOF compared to the conventional microscope counterparts. (C) 2010 Optical Society of America
引用
收藏
页码:353 / 362
页数:10
相关论文
共 16 条
[1]   Model-based 2.5-d deconvolution for extended depth of field in brightfield microscopy [J].
Aguet, Francois ;
De Ville, Dimitri Van ;
Unser, Michael .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 2008, 17 (07) :1144-1153
[2]   Optical sectioning microscopy [J].
Conchello, JA ;
Lichtman, JW .
NATURE METHODS, 2005, 2 (12) :920-931
[3]   Extended depth-of-focus microscopy via constrained deconvolution [J].
Conchello, Jose-Angel ;
Dresser, Michael E. .
JOURNAL OF BIOMEDICAL OPTICS, 2007, 12 (06)
[4]   EXTENDED DEPTH OF FIELD THROUGH WAVE-FRONT CODING [J].
DOWSKI, ER ;
CATHEY, WT .
APPLIED OPTICS, 1995, 34 (11) :1859-1866
[5]   Deep tissue two-photon microscopy [J].
Helmchen, F ;
Denk, W .
NATURE METHODS, 2005, 2 (12) :932-940
[6]   Optical sectioning deep inside live embryos by selective plane illumination microscopy [J].
Huisken, J ;
Swoger, J ;
Del Bene, F ;
Wittbrodt, J ;
Stelzer, EHK .
SCIENCE, 2004, 305 (5686) :1007-1009
[7]   Time-multiplexed dual-focal plane head-mounted display with a liquid lens [J].
Liu, Sheng ;
Hua, Hong .
OPTICS LETTERS, 2009, 34 (11) :1642-1644
[8]   Three-dimensional adaptive microscopy using embedded liquid lens [J].
Murali, Supraia ;
Thompson, Kevin P. ;
Rolland, Jannick P. .
OPTICS LETTERS, 2009, 34 (02) :145-147
[9]   Method of obtaining optical sectioning by using structured light in a conventional microscope [J].
Neil, MAA ;
Juskaitis, R ;
Wilson, T .
OPTICS LETTERS, 1997, 22 (24) :1905-1907
[10]   Extended depth of field imaging for high speed cell analysis [J].
Ortyn, William E. ;
Perry, David J. ;
Venkatachalam, Vidya ;
Liang, Luchuan ;
Hall, Brian E. ;
Frost, Keith ;
Basiji, David A. .
CYTOMETRY PART A, 2007, 71A (04) :215-231