Quantitative evaluation of reversed-phase packing material based on calcium carbonate microspheres modified with an alternating copolymer

被引:5
|
作者
Kaizu, Kogi [1 ]
Mochida, Mai [1 ]
Imai, Hiroaki [1 ]
Citterio, Daniel [1 ]
Hiruta, Yuki [1 ]
机构
[1] Keio Univ, Dept Appl Chem, 3-14-1 Hiyoshi,Kohoku ku, Yokohama, Kanagawa, Japan
基金
日本科学技术振兴机构;
关键词
Reversed -phase chromatography; Calcium carbonate; Alternating copolymer; Alkali resistance; Basic drug; PERFORMANCE LIQUID-CHROMATOGRAPHY; STATIONARY PHASES; MODIFIED SILICA; CORE-SHELL; RETENTION;
D O I
10.1016/j.chroma.2022.463294
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Considering the vulnerability of silica gel to alkaline mobile phases, a highly alkaline stable stationary phase for HPLC is required to separate basic compounds with high separation efficiency. To address this issue, we have developed a high alkaline stable packing material (CaCO 3 -PMAcO) based on mesoporous calcium carbonate microspheres modified with poly(maleic acid- alt -1-octadecene). In this study, we report further investigation of the separation performance of CaCO 3 -PMAcO column by systematically evaluating the effects of particle size and chromatographic conditions. Based on the theory of the van Deemter equation, the separation efficiency was related to the size of CaCO 3 -PMAcO particles (2.9 - 5.7 mu m). The evaluation of thermodynamics of retention by changing the column temperature from 20 degrees C to 45 degrees C implied that the retention mode was dominated by hydrophobic interaction associated with the exothermic enthalpy changes (-11.1 to -12.5 kJ/mol). The results of column selectivity tests revealed that the CaCO 3 -PMAcO column had hydrophobic selectivity comparable to C 18 silica gel columns ( alpha P/B ; CaCO 3 -PMAcO column: 1.53, C 18 column: 1.69), and higher shape/steric selectivity ( alpha Tri/Ter ; CaCO 3 PMAcO column: 1.56, C 18 column: 0.955). In practice, the CaCO 3 -PMAcO column could be applied to the separation of not only alkylbenzenes and polycyclic aromatic hydrocarbons, but also to basic tricyclic antidepressants by using an alkaline mobile phase (pH 12).(c) 2022 Elsevier B.V. All rights reserved.
引用
收藏
页数:7
相关论文
共 26 条
  • [1] Fabrication process development and basic evaluation of eggshell-based column packing material for reversed-phase preparative separation
    Yoshii, Tomoka
    Sakama, Akihiro
    Kanamori, Kazuyoshi
    Nakanishi, Kazuki
    Imai, Hiroaki
    Citterio, Daniel
    Hiruta, Yuki
    JOURNAL OF CHROMATOGRAPHY A, 2023, 1688
  • [2] A biomimetic hybrid material consisting of CaCO3 mesoporous microspheres and an alternating copolymer for reversed-phase HPLC
    Mochida, Mai
    Nagai, Yuta
    Kumagai, Hiroto
    Imai, Hiroaki
    Citterio, Daniel
    Hiruta, Yuki
    JOURNAL OF MATERIALS CHEMISTRY B, 2019, 7 (31) : 4771 - 4777
  • [3] Facile preparation of an alternating copolymer-based high molecular shape-selective organic phase for reversed-phase liquid chromatography
    Mallik, Abul K.
    Noguchi, Hiroki
    Rahman, Mohammed Mizanur
    Takafuji, Makoto
    Ihara, Hirotaka
    JOURNAL OF CHROMATOGRAPHY A, 2018, 1555 : 53 - 61
  • [4] Porous Polymeric Substrates Based on a Styrene-Divinylbenzene Copolymer for Reversed-Phase and Ion Chromatography
    Loshin, A. A.
    Smolenkov, A. D.
    Shpigun, O. A.
    MOSCOW UNIVERSITY CHEMISTRY BULLETIN, 2022, 77 (02) : 68 - 89
  • [5] Porous Polymeric Substrates Based on a Styrene–Divinylbenzene Copolymer for Reversed-Phase and Ion Chromatography
    A. A. Loshin
    A. D. Smolenkov
    O. A. Shpigun
    Moscow University Chemistry Bulletin, 2022, 77 : 68 - 89
  • [6] Use of alumina with anchored polymer coating as packing material for reversed-phase high-performance liquid chromatography
    Mao, Y
    Fung, BM
    JOURNAL OF CHROMATOGRAPHY A, 1997, 790 (1-2) : 9 - 15
  • [7] Novel Approach for the Separation of Shape-Constrained Isomers with Alternating Copolymer-Grafted Silica in Reversed-Phase Liquid Chromatography
    Mallik, Abul K.
    Sawada, Tsuyoshi
    Takafuji, Makoto
    Ihara, Hirotaka
    ANALYTICAL CHEMISTRY, 2010, 82 (08) : 3320 - 3328
  • [8] Synthesis of porous spherical silicon oxynitride material and evaluation of its properties in reversed-phase chromatographic separation
    Zhong Hongmin
    Zhang Hua
    Wan Huihui
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2013, 31 (04) : 342 - 347
  • [9] Optimization and qualification of a quantitative reversed-phase HPLC method for hemagglutinin in influenza preparations and its comparative evaluation with biochemical assays
    Lorbetskie, Barry
    Wang, Jun
    Gravel, Caroline
    Allen, Cynthia
    Walsh, Mike
    Rinfret, Aline
    Li, Xuguang
    Girard, Michel
    VACCINE, 2011, 29 (18) : 3377 - 3389
  • [10] Performance evaluation of green and conventional solvents in reversed-phase liquid chromatography based on the separation of non-polar and polar substances
    Kalisz, Oktawia
    Hulicka, Gabriela
    Tobiszewski, Marek
    Bocian, Szymon
    GREEN CHEMISTRY, 2025, 27 (11) : 3020 - 3031