Multislice Computed Tomography for Prediction of Optimal Angiographic Deployment Projections During Transcatheter Aortic Valve Implantation

被引:110
作者
Gurvitch, Ronen [1 ]
Wood, David A. [1 ]
Leipsic, Jonathon [1 ]
Tay, Edgar [1 ]
Johnson, Mark [1 ]
Ye, Jian [1 ]
Nietlispach, Fabian [1 ]
Wijesinghe, Namal [1 ]
Cheung, Anson [1 ]
Webb, John G. [1 ]
机构
[1] Univ British Columbia, St Pauls Hosp, Vancouver, BC V6Z 1Y6, Canada
关键词
aortic stenosis; multislice computed tomography; transcatheter aortic valve implantation; ROOT; REPLACEMENT; DIMENSIONS; MANAGEMENT;
D O I
10.1016/j.jcin.2010.09.010
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives This study assessed whether multislice computed tomography (MSCT) could predict optimal angiographic projections for visualizing the plane of the native valve and facilitate accurate positioning during transcatheter aortic valve implantation (TAVI). Background Accurate device positioning during TAVI depends on valve deployment in angiographic projections perpendicular to the native valve plane, but these may be difficult to determine. Methods Twenty patients underwent MSCT before TAVI. Using a novel technique, multiple angiographic projections accurately representing the native valve plane in multiple axes were determined. The accuracy of all predicted projections was determined post-procedure using angiography according to new criteria, based on valve perpendicularity and the degree of strut overlap (defined as excellent, satisfactory, or poor). The accuracy of valve deployment using MSCT was compared with the results of 20 consecutive patients undergoing TAVI without such MSCT angle prediction. Results Correct final deployment projections were more frequent in the MSCT-guided compared with non MSCT-guided group: excellent or satisfactory projections (90% vs. 65%, p = 0.06). The MSCT angle prediction was accurate but dependent on optimal images (optimal images: 93% of predicted angles were excellent or satisfactory, suboptimal images: 73% of predicted angles were poor). A "line of perpendicularity" could be generated with optimal projections across the right-to-left anterior oblique plane by adding the correct cranial or caudal angulation. Conclusions Pre-procedural MSCT can predict optimal angiographic deployment projections for implantation of transcatheter valves. An ideal deployment angle curve or "line of perpendicularity" can be generated. Understanding and applying these principles improves the accuracy of valve deployment and may improve outcomes. (J Am Coll Cardiol Intv 2010;3:1157-65) (C) 2010 by the American College of Cardiology Foundation
引用
收藏
页码:1157 / 1165
页数:9
相关论文
共 13 条
  • [11] WIJESINGHE N, 2010, J AM COLL CARDIOL S1, V55
  • [12] Technical considerations to avoid pitfalls during transapical aortic valve implantation
    Wong, Daniel R.
    Ye, Jian
    Cheung, Anson
    Webb, John G.
    Carere, Ronald G.
    Lichtenstein, Samuel V.
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2010, 140 (01) : 196 - 202
  • [13] Role of Multislice Computed Tomography in Transcatheter Aortic Valve Replacement
    Wood, David A.
    Tops, Laurens F.
    Mayo, John R.
    Pasupati, Sanjeevan
    Schalij, Martin J.
    Humphries, Karin
    Lee, May
    Al Ali, Abdullah
    Munt, Brad
    Moss, Rob
    Thompson, Christopher R.
    Bax, Jeroen J.
    Webb, John G.
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2009, 103 (09) : 1295 - 1301