Multislice Computed Tomography for Prediction of Optimal Angiographic Deployment Projections During Transcatheter Aortic Valve Implantation

被引:110
作者
Gurvitch, Ronen [1 ]
Wood, David A. [1 ]
Leipsic, Jonathon [1 ]
Tay, Edgar [1 ]
Johnson, Mark [1 ]
Ye, Jian [1 ]
Nietlispach, Fabian [1 ]
Wijesinghe, Namal [1 ]
Cheung, Anson [1 ]
Webb, John G. [1 ]
机构
[1] Univ British Columbia, St Pauls Hosp, Vancouver, BC V6Z 1Y6, Canada
关键词
aortic stenosis; multislice computed tomography; transcatheter aortic valve implantation; ROOT; REPLACEMENT; DIMENSIONS; MANAGEMENT;
D O I
10.1016/j.jcin.2010.09.010
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives This study assessed whether multislice computed tomography (MSCT) could predict optimal angiographic projections for visualizing the plane of the native valve and facilitate accurate positioning during transcatheter aortic valve implantation (TAVI). Background Accurate device positioning during TAVI depends on valve deployment in angiographic projections perpendicular to the native valve plane, but these may be difficult to determine. Methods Twenty patients underwent MSCT before TAVI. Using a novel technique, multiple angiographic projections accurately representing the native valve plane in multiple axes were determined. The accuracy of all predicted projections was determined post-procedure using angiography according to new criteria, based on valve perpendicularity and the degree of strut overlap (defined as excellent, satisfactory, or poor). The accuracy of valve deployment using MSCT was compared with the results of 20 consecutive patients undergoing TAVI without such MSCT angle prediction. Results Correct final deployment projections were more frequent in the MSCT-guided compared with non MSCT-guided group: excellent or satisfactory projections (90% vs. 65%, p = 0.06). The MSCT angle prediction was accurate but dependent on optimal images (optimal images: 93% of predicted angles were excellent or satisfactory, suboptimal images: 73% of predicted angles were poor). A "line of perpendicularity" could be generated with optimal projections across the right-to-left anterior oblique plane by adding the correct cranial or caudal angulation. Conclusions Pre-procedural MSCT can predict optimal angiographic deployment projections for implantation of transcatheter valves. An ideal deployment angle curve or "line of perpendicularity" can be generated. Understanding and applying these principles improves the accuracy of valve deployment and may improve outcomes. (J Am Coll Cardiol Intv 2010;3:1157-65) (C) 2010 by the American College of Cardiology Foundation
引用
收藏
页码:1157 / 1165
页数:9
相关论文
共 13 条
  • [1] Prevention and Management of Transcatheter Balloon-Expandable Aortic Valve Malposition
    Al Ali, Abdullah M.
    Altwegg, Lukas
    Horlick, Eric M.
    Feindel, Christopher
    Thompson, Christopher R.
    Cheung, Anson
    Carere, Ronald G.
    Humphries, Karin
    Ye, Jian
    Masson, Jean-Bernard
    Webb, John G.
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2008, 72 (04) : 573 - 578
  • [2] Pre-Procedural Imaging of Aortic Root Orientation and Dimensions Comparison Between X-Ray Angiographic Planar Imaging and 3-Dimensional Multidetector Row Computed Tomography
    Kurra, Vikram
    Kapadia, Samir R.
    Tuzcu, E. Murat
    Halliburton, Sandra S.
    Svensson, Lars
    Roselli, Eric E.
    Schoenhagen, Paul
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2010, 3 (01) : 105 - 113
  • [3] Leipsic Jonathon, 2009, AJR Am J Roentgenol, V193, pW214, DOI 10.2214/AJR.08.2230
  • [4] Transcatheter Aortic Valve Implantation Review of the Nature, Management, and Avoidance of Procedural Complications
    Masson, Jean-Bernard
    Kovac, Jan
    Schuler, Gerhard
    Ye, Jian
    Cheung, Anson
    Kapadia, Samir
    Tuzcu, Murat E.
    Kodali, Susheel
    Leon, Martin B.
    Webb, John G.
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2009, 2 (09) : 811 - 820
  • [5] Comparison of Aortic Root Dimensions and Geometries Before and After Transcatheter Aortic Valve Implantation by 2-and 3-Dimensional Transesophageal Echocardiography and Multislice Computed Tomography
    Ng, Arnold C. T.
    Delgado, Victoria
    van der Kley, Frank
    Shanks, Miriam
    van de Veire, Nico R. L.
    Bertini, Matteo
    Nucifora, Gaetano
    van Bommel, Rutger J.
    Tops, Laurens F.
    de Weger, Arend
    Tavilla, Giuseppe
    de Roos, Albert
    Kroft, Lucia J.
    Leung, Dominic Y.
    Schuijf, Joanne
    Schalij, Martin J.
    Bax, Jeroen J.
    [J]. CIRCULATION-CARDIOVASCULAR IMAGING, 2010, 3 (01) : 94 - 102
  • [6] CONGENITALLY BICUSPID AORTIC VALVE - A STUDY OF 85 AUTOPSY CASES
    ROBERTS, WC
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1970, 26 (01) : 72 - &
  • [7] Congenitally bicuspid aortic valves: A surgical pathology study of 542 cases (1991 through 1996) and a literature review of 2,715 additional cases
    Sabet, HY
    Edwards, WD
    Tazelaar, HD
    Daly, RC
    [J]. MAYO CLINIC PROCEEDINGS, 1999, 74 (01) : 14 - 26
  • [8] Tamburino C, 2009, J INVASIVE CARDIOL, V21, P93
  • [9] Noninvasive Evaluation of the Aortic Root With Multislice Computed Tomography Implications for Transcatheter Aortic Valve Replacement
    Tops, Laurens F.
    Wood, David A.
    Delgado, Victoria
    Schuijf, Joanne D.
    Mayo, John R.
    Pasupati, Sanjeevan
    Lamers, Frouke P. L.
    van der Wall, Ernst E.
    Schalij, Martin J.
    Webb, John G.
    Bax, Jeroen J.
    [J]. JACC-CARDIOVASCULAR IMAGING, 2008, 1 (03) : 321 - 330
  • [10] Transcatheter Aortic Valve Implantation Impact on Clinical and Valve-Related Outcomes
    Webb, John G.
    Altwegg, Lukas
    Boone, Robert H.
    Cheung, Anson
    Ye, Jian
    Lichtenstein, Samuel
    Lee, May
    Masson, Jean Bernard
    Thompson, Christopher
    Moss, Robert
    Carere, Ron
    Munt, Brad
    Nietlispach, Fabian
    Humphries, Karin
    [J]. CIRCULATION, 2009, 119 (23) : 3009 - 3016