Thermal performance of back-up current-limiting fuses

被引:15
|
作者
Torres, E. [1 ]
Mazon, A. J. [1 ]
Fernandez, E. [1 ]
Zamora, I. [1 ]
Perez, J. C. [2 ]
机构
[1] Univ Basque Country UPV EHU, Dept Elect Engn, Bilbao 48013, Bizkaia, Spain
[2] MESA Schneider Elect, Gatica 48110, Spain
关键词
Current-limiting fuses; Thermal analysis; Temperature distribution;
D O I
10.1016/j.epsr.2010.06.010
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The design and development of current-limiting power fuses requires considerable time and expense on testing to verify that the maximum temperature limits under the rated current established in international standards are not exceeded. This paper presents a new methodology that reproduces the thermal behaviour of high voltage current-limiting fuses under currents up to the rated value and so, it reduces the need for testing as prototypes, more similar to the final design, can be obtained. Firstly, the methodology solves the transient heating process of the fuse to obtain the values of the power dissipated and the heat transfer coefficient, corresponding to the steady state condition. Once these values have been calculated, the temperature distribution at the surface of the complete fuse is obtained. The validity of the method proposed has been verified by comparison of the numerical values calculated with those obtained by testing real fuses. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:1469 / 1476
页数:8
相关论文
共 50 条
  • [1] Current-limiting fuses: Coordination
    Leach, JG
    2003 IEEE PES TRANSMISSION AND DISTRIBUTION CONFERENCE & EXPOSITION, VOLS 1-3, CONFERENCE PROCEEDINGS: BLAZING TRAILS IN ENERGY DELIVERY AND SERVICES, 2003, : 1212 - 1214
  • [2] Current-limiting fuses: Coordination
    Leach, JG
    2003 IEEE PES TRANSMISSION AND DISTRIBUTION CONFERENCE & EXPOSITION, VOLS 1-3, CONFERENCE PROCEEDINGS: BLAZING TRAILS IN ENERGY DELIVERY AND SERVICES, 2003, : 1241 - 1243
  • [3] ENERGY LIMITING CHARACTERISTICS OF CURRENT-LIMITING FUSES
    ARNDT, RH
    KOTSKI, EJ
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1976, 95 (06): : 1768 - 1768
  • [4] PROPER APPLICATION OF CURRENT-LIMITING FUSES
    SCHAFFER, S
    EC&M-ELECTRICAL CONSTRUCTION AND MAINTENANCE, 1983, 82 (08): : 51 - 56
  • [5] PROTECTIVE CHARACTERISTICS OF CURRENT-LIMITING CAPACITOR FUSES
    HUBER, WJ
    AMUNDSON, RH
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1975, 94 (06): : 2023 - 2026
  • [7] Current-limiting fuses improve power quality
    Kojovic, LA
    Hassler, SP
    Singh, H
    Williams, CW
    2001 IEEE/PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXPOSITION, VOLS 1 AND 2: DEVELOPING NEW PERSPECTIVES, 2001, : 281 - 286
  • [8] COORDINATION OF LIGHTNING ARRESTERS AND CURRENT-LIMITING FUSES
    BOEHNE, EW
    GAIBROIS, GL
    MIKULECK.HW
    KOCH, RE
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1972, PA91 (03): : 1075 - &
  • [9] COORDINATING OF FAULT INDICATORS AND CURRENT-LIMITING FUSES
    AMUNDSON, RH
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1977, 96 (04): : 1066 - 1066
  • [10] Applying current-limiting fuses to improve power quality and safety
    Leix, KL
    Kojovic, LA
    Marz, MB
    Lampley, GC
    1999 IEEE TRANSMISSION AND DISTRIBUTION CONFERENCE, VOLS 1 & 2, 1999, : 636 - 641