Patient's Peak Skin Dose evaluation using Gafchromic films in interventional cardiology procedures and its correlation with other dose indicators

被引:10
作者
Pasquino, M. [1 ]
Cutaia, C. [1 ]
Poli, M. [1 ]
Valero, C. [1 ]
Peroni, G. [1 ]
De Benedictis, M. [2 ]
Petrucci, E. [3 ]
Stasi, M. [1 ]
机构
[1] AO Mauriziano, I-10128 Turin, Italy
[2] AO Mauriziano, Dept Cardiol, I-10128 Turin, Italy
[3] ASL, Dept Med Phys, TO4, I-10015 Ivrea, Italy
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2018年 / 53卷
关键词
Interventional cardiology; Peak Skin Dose; Deterministic effects; Gafchromic films; RADIOLOGY; INJURIES; ORGAN;
D O I
10.1016/j.ejmp.2018.08.017
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: Number and complexity of interventional cardiology procedures have increased during last years and can result in patient skin dose high enough to cause deterministic skin effects. The aim of the work is to investigate the correlation between Peak Skin Dose (PSD) and the dosimetric indicators directly registered by the radiological equipment and provide the physicians a tool to identify patients at risk of deterministic effects and include them into a follow-up program. Methods: PSD was measured in vivo using radiochromic Gafchromic XR-RV3 films, properly calibrated. DAP, Cumulative Dose at the interventional reference point (CD) and exposure time of each procedure were retrieved from the Radiation Dose Structured Reports created by an Allura Clarity Xper FD20 angiographic system. Linear correlation between PSD and both DAP and CD was investigated. Results: 42 interventional cardiology procedures (16 CA and 26 PTCA) were involved in the study. The dosimetric indicators values for PTCA are generally higher than those for CA, due to the different levels of procedure complexity. Mean PSD values were (103 +/- 64) and (526 +/- 436) mGy for CA and PTCA procedures. For CA, we found strong correlation both between PSD and DAP (r = 0.753) and PSD and CD (r = 0.782). For PTCA, good correlation both for DAP (r = 0.648) and CD (r = 0.649) was found. Conclusions: DAP and CD show strong correlation with PSD measured with Gafchromic films during interventional procedures. The proposed method allows the physician to estimate patient's PSD from the dosimetric indicators that the radiological equipment display and record at the end of the procedure.
引用
收藏
页码:103 / 107
页数:5
相关论文
共 21 条
  • [1] Aly A.E., 2015, Int. J. Med. Phys. Clin. Eng. Radiat. Oncol, V4, P7, DOI DOI 10.4236/IJMPCERO.2015.41002
  • [2] [Anonymous], ISP REC
  • [3] Fluoroscopically Guided Interventional Procedures: A Review of Radiation Effects on Patients' Skin and Hair
    Balter, Stephen
    Hopewell, John W.
    Miller, Donald L.
    Wagner, Louis K.
    Zelefsky, Michael J.
    [J]. RADIOLOGY, 2010, 254 (02) : 326 - 341
  • [4] Conversion factors of effective and equivalent organ doses with the air kerma area product in patients undergoing coronary angiography and percutaneous coronary interventions
    Brambilla, M.
    Cannillo, B.
    Matheoud, R.
    Compagnone, G.
    Rognoni, A.
    Bongo, A. S.
    Carriero, A.
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 42 : 189 - 196
  • [5] Measurement of maximum skin dose in interventional radiology and cardiology and challenges in the set-up of European alert thresholds
    Farah, J.
    Trianni, A.
    Carinou, E.
    Ciraj-Bjelac, O.
    Clairand, I.
    Dabin, J.
    De Angelis, C.
    Domienik, J.
    Jarvinen, H.
    Kopec, R.
    Majer, M.
    Malchair, F.
    Negri, A.
    Novak, L.
    Siiskonen, T.
    Vanhavere, F.
    Knezevic, Z.
    [J]. RADIATION PROTECTION DOSIMETRY, 2015, 164 (1-2) : 138 - 142
  • [6] Assessment of peak skin dose in interventional cardiology: A comparison between Gafchromic film and dosimetric software em. dose
    Greffier, J.
    Ty, C. Van Ngoc
    Bonniaud, G.
    Moliner, G.
    Ledermann, B.
    Schmutz, L.
    Cornillet, L.
    Cayla, G.
    Beregi, J. P.
    Pereira, F.
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 38 : 16 - 22
  • [7] ASSESSMENT OF PATIENT'S PEAK SKIN DOSE USING GAFCHROMIC FILMS DURING INTERVENTIONAL CARDIOLOGY PROCEDURES: ROUTINE EXPERIENCE FEEDBACK
    Greffier, J.
    Moliner, G.
    Pereira, F.
    Cornillet, L.
    Ledermann, B.
    Schmutz, L.
    Lomma, M.
    Cayla, G.
    Beregi, J. P.
    [J]. RADIATION PROTECTION DOSIMETRY, 2017, 174 (03) : 395 - 405
  • [8] International Commission on Radiological Protection (ICRP), 2000, ANN ICRP, VVolume 30, DOI 10.1177/ANIB_30_2
  • [9] Skin injuries from fluoroscopically guided procedures: part I, Characteristics of radiation injury
    Koenig, TR
    Wolff, D
    Mettler, FA
    Wagner, LK
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 177 (01) : 3 - 11
  • [10] Towards the definition of Institutional diagnostic reference levels in paediatric interventional cardiology procedures in Greece
    Kottou, S.
    Kollaros, N.
    Plemmenos, C.
    Mastorakou, I.
    Apostolopoulou, S. C.
    Tsapaki, V.
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 46 : 52 - 58