The effect of adjunctive mitomycin C in Ahmed glaucoma valve implantation

被引:38
作者
Kurnaz, E [1 ]
Kubaloglu, A [1 ]
Yilmaz, Y [1 ]
Koytak, A [1 ]
Özertürk, Y [1 ]
机构
[1] Educ & Res Hosp, Dept Ophthalmol, Istanbul, Turkey
关键词
refractory glaucoma; Ahmed glaucoma valve; mitomycin C;
D O I
10.1177/112067210501500105
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To evaluate the effectiveness and safety of adjunctive mitomycin C (MMC) in Ahmed glaucoma valve (AGV) implantation for refractory glaucoma. METHODs. Twenty-two eyes of 22 patients who underwent AGV implantation with adjunctive MMC (0.5 mg/ml) for 3 minutes (Group A) were compared to a control group of 26 eyes of 26 patients (Group B) who received AGV implantation without MMC. Nine patients were female and 13 patients were male in Group A and 11 patients were female and 15 patients were male in Group B. The mean age was 56 years ranging from 13 to 77 in Group A and 58 ranging from 14 to 71 years in Group B. Success was defined as an intraocular pressure (IOP) between 4 and 21 mmHg with or without glaucoma medication and with no additional glaucoma surgery, phthisis, or loss of light perception. RESULTS. The probability of success at 1 year was 86.36% and 80.76% in Group A and Group B, respectively. The number of glaucoma medications decreased from 2.82 to 0.56 in Group A and from 2.65 to 0.73 in Group B. Postoperative hypotony as an early complication was higher in Group A (31.81% in Group A and 15.38% in Group B). As a late postoperative complication, tube exposure developed in 3 patients (13.63%) in Group A and no such complication was seen in Group B. There was no statistically significant difference in success and complication rates between the two groups (p > 0.05). CONCLUSIONS. Although adjunctive MMC in AGV implantation is safe and effective, it may not offer a better chance of surgical success compared with AGV implantation without MMC.
引用
收藏
页码:27 / 31
页数:5
相关论文
共 26 条
[1]   A clinical study of the Ahmed glaucoma valve implant in advanced glaucoma [J].
Ayyala, RS ;
Zurakowski, D ;
Smith, JA ;
Monshizadeh, R ;
Netland, PA ;
Richards, DW ;
Layden, WE .
OPHTHALMOLOGY, 1998, 105 (10) :1968-1976
[2]  
Ayyala RS, 2001, OPHTHALMIC SURG LAS, V32, P248
[3]  
AzuaraBlanco A, 1997, OPHTHALMIC SURG LAS, V28, P992
[4]   THE EFFECTS OF SUBCONJUNCTIVAL MITOMYCIN-C ON GLAUCOMA FILTRATION SURGERY IN RABBITS [J].
BERGSTROM, TJ ;
WILKINSON, WS ;
SKUTA, GL ;
WATNICK, RL ;
ELNER, VM .
ARCHIVES OF OPHTHALMOLOGY, 1991, 109 (12) :1725-1730
[5]   PATCH GRAFTS OF DEHYDRATED CADAVERIC DURA-MATER FOR TUBE-SHUNT GLAUCOMA SURGERY [J].
BRANDT, JD .
ARCHIVES OF OPHTHALMOLOGY, 1993, 111 (10) :1436-1439
[6]  
Cantor L, 1998, J GLAUCOMA, V7, P240
[7]   INITIAL CLINICAL-EXPERIENCE WITH THE AHMED GLAUCOMA VALVE IMPLANT [J].
COLEMAN, AL ;
HILL, R ;
WILSON, MR ;
CHOPLIN, N ;
KOTASNEUMANN, R ;
TAM, M ;
BACHARACH, J ;
PANEK, WC .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1995, 120 (01) :23-31
[8]   EFFECTS OF TOPICAL MITOMYCIN-C ON PRIMARY TRABECULECTOMIES AND COMBINED PROCEDURES [J].
COSTA, VP ;
MOSTER, MR ;
WILSON, RP ;
SCHMIDT, CM ;
GANDHAM, S ;
SMITH, M .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1993, 77 (11) :693-697
[9]   Characteristics of glaucoma drainage implants during dynamic and steady-state flow conditions [J].
Francis, BA ;
Cortes, A ;
Chen, J ;
Alvarado, JA .
OPHTHALMOLOGY, 1998, 105 (09) :1708-1714
[10]  
HAUBER F, 1994, OPHTHALMIC PRACTICE, V12, P3