Cavity-Enhanced Near-Infrared Laser Absorption Spectrometer for the Measurement of Acetonitrile in Breath

被引:13
作者
Gianella, Michele [1 ]
Ritchie, Grant A. D. [1 ]
机构
[1] Univ Oxford, Dept Chem, Phys & Theoret Chem Lab, Oxford OX1 3QZ, England
关键词
PSEUDOMONAS-AERUGINOSA; HYDROGEN-CYANIDE; NITRIC-OXIDE; GAS; SPECTROSCOPY; DIAGNOSIS; CHILDREN; CANCER; RING;
D O I
10.1021/acs.analchem.5b01341
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Elevated concentrations of acetonitrile have been found in the exhaled breath of patients with cystic fibrosis' and may indicate the severity of their condition or the presence of an accompanying bacterial infection of the airways. There is therefore interest in detecting acetonitrile in exhaled breath. For this purpose, a cavity-enhanced laser absorption spectrometer (lambda = 1.65 mu m) with a preconcentration stage was built and is described here. The spectrometer has a limit of detection of 72 ppbv and 114 ppbv of acetonitrile in nitrogen and breath, respectively, with a measurement duration of just under 5 min. The preconcentration stage, which employs a carbon molecular sieve and an adsorption/thermal desorption cycle, can increase the acetonitrile concentration by up to a factor 93, thus, lowering the overall limit of detection to approximately 1 ppbv. The suitability of the system for acetonitrile measurements in breath is demonstrated with breath samples taken from the authors, which yielded acetonitrile concentrations of 23 +/- 3 ppbv and 29 +/- 3 ppbv, respectively.
引用
收藏
页码:6881 / 6889
页数:9
相关论文
共 36 条
[11]   Exhaled and nasal nitric oxide measurements: Recommendations [J].
Kharitonov, S ;
Alving, K ;
Barnes, PJ .
EUROPEAN RESPIRATORY JOURNAL, 1997, 10 (07) :1683-1693
[12]   Cavity ringdown spectroscopic detection of nitric oxide with a continuous-wave quantum-cascade laser [J].
Kosterev, AA ;
Malinovsky, AL ;
Tittel, FK ;
Gmachl, C ;
Capasso, F ;
Sivco, DL ;
Baillargeon, JN ;
Hutchinson, AL ;
Cho, AY .
APPLIED OPTICS, 2001, 40 (30) :5522-5529
[13]   Pseudomonas aeruginosa and cyanide production [J].
Lenney, W. ;
Gilchrist, F. J. .
EUROPEAN RESPIRATORY JOURNAL, 2011, 37 (03) :482-483
[14]   PRODUCTION AND EXCRETION OF HYDROGEN GAS IN MAN [J].
LEVITT, MD .
NEW ENGLAND JOURNAL OF MEDICINE, 1969, 281 (03) :122-&
[15]   Quantification of recent smoking behaviour using proton transfer reaction-mass spectrometry (PTR-MS) [J].
Lirk, P ;
Bodrogi, F ;
Deibl, M ;
Kähler, CM ;
Colvin, J ;
Moser, B ;
Pinggera, G ;
Raifer, H ;
Rieder, J ;
Schobersberger, W .
WIENER KLINISCHE WOCHENSCHRIFT, 2004, 116 (1-2) :21-25
[16]   Determination of breath gas composition of lung cancer patients using gas chromatography/mass spectrometry with monolithic material sorptive extraction [J].
Ma, Wen ;
Gao, Peng ;
Fan, Jun ;
Hashi, Yuki ;
Chen, Zilin .
BIOMEDICAL CHROMATOGRAPHY, 2015, 29 (06) :961-965
[17]  
MANOLIS A, 1983, CLIN CHEM, V29, P5
[18]  
Mazurenka M, 2005, ANN RP CH C, V101, P100, DOI 10.1039/b408909j
[19]   Real-time monitoring of hydrogen cyanide (HCN) and ammonia (NH3) emitted by Pseudomonas aeruginosa [J].
Neerincx, Anne H. ;
Mandon, Julien ;
van Ingen, Jakko ;
Arslanov, Denis D. ;
Mouton, Johan W. ;
Harren, Frans J. M. ;
Merkus, Peter J. F. M. ;
Cristescu, Simona M. .
JOURNAL OF BREATH RESEARCH, 2015, 9 (02)
[20]   Off-axis integrated cavity output spectroscopy with a mid-infrared interband cascade laser for real-time breath ethane measurements [J].
Parameswaran, Krishnan R. ;
Rosen, David I. ;
Allen, Mark G. ;
Ganz, Alan M. ;
Risby, Terence H. .
APPLIED OPTICS, 2009, 48 (04) :B73-B79