Comparison between different cone -beam computed tomography devices in the detection of mechanically simulated peri-implant bone defects

被引:5
作者
Kim, Jun Ho [1 ]
Abdala-Junior, Reinaldo [1 ]
Munhoz, Luciana [1 ]
Cortes, Arthur Rodriguez Gonzalez [1 ,3 ]
Watanabe, Plauto Christopher Aranha [2 ]
Costa, Claudio [1 ]
Arita, Emiko Saito [1 ]
机构
[1] Univ Sao Paulo, Sch Dent, Dept Stomatol, Ave Prof Lineu Prestes 2227, BR-05508000 Sao Paulo, SP, Brazil
[2] Univ Sao Paulo, Sch Dent Ribeirao Preto, Dept Stomatol, Field Publ Oral Hlth & Forens Dent, Ribeirao Preto, Brazil
[3] Univ Malta, Mater Dei Hosp, Fac Dent Surg, Dept Dent Surg, Msida, Malta
关键词
Peri-Implantitis; Dental Implants; Cone-Beam Computed Tomography; PERIAPICAL RADIOGRAPHY; IN-VITRO; DEHISCENCE; ARTIFACTS; ACCURACY;
D O I
10.5624/isd.2020.50.2.133
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose : This study compared 2 cone-beam computed tomography (CBCT) systems in the detection of mech- anically simulated peri-implant buccal bone defects in dry human mandibles. Materials and Methods : Twenty-four implants were placed in 7 dry human mandibles. Peri-implant bone defects were created in the buccal plates of 16 implants using spherical burs. All mandibles were scanned using 2 CBCT systems with their commonly used acquisition protocols: i-CAT Gendex CB-500 (Imaging Sciences, Hatfield, PA, USA; field of view [FOV], 8 cm x 8 cm; voxel size, 0.125 mm; 120 kVp; 5 mA; 23 s) and Orthopantomograph OP300 (Intrumentarium, Tuusula, Finland; FOV, 6 cm x 8 cm; voxel size, 0.085 mm; 90 kVp; 6.3 mA; 13 s). Two oral and maxillofacial radiologists assessed the CBCT images for the presence of a defect and measured the depth of the bone defects. Diagnostic performance was compared in terms of the area under the curve (AUC), accuracy, sensitivity, specificity, and intraclass correlation coefficient. Results : High intraobserver and interobserver agreement was found (P < 0.05). The OP300 showed slightly better diagnostic performance and higher detection rates than the CB-500 (AUC, 0.56 +/- 0.03), with a mean accuracy of 75.0%, sensitivity of 81.2%, and specificity of 62.5%. Higher contrast was observed with the CB-500, whereas the OP300 formed more artifacts. Conclusion : Within the limitations of this study, the present results suggest that the choice of CBCT systems with their respective commonly used acquisition protocols does not significantly affect diagnostic performance in detecting and measuring buccal peri-implant bone loss. (Imaging Sci Dent 2020; 50: 133-9)
引用
收藏
页码:133 / 139
页数:7
相关论文
共 50 条
  • [41] Peri-implant bone tissue assessment by comparing the outcome of intra-oral radiograph and cone beam computed tomography analyses to the histological standard
    Corpas, Livia dos Santos
    Jacobs, Reinhilde
    Quirynen, Marc
    Huang, Yan
    Naert, Ignace
    Duyck, Joke
    CLINICAL ORAL IMPLANTS RESEARCH, 2011, 22 (05) : 492 - 499
  • [42] Accuracy of cone-beam computed tomography is limited at implant sites with a thin buccal bone: A laboratory study
    Domic, Danijel
    Bertl, Kristina
    Ahmad, Salman
    Schropp, Lars
    Hellen-Halme, Kristina
    Stavropoulos, Andreas
    JOURNAL OF PERIODONTOLOGY, 2021, 92 (04) : 592 - 601
  • [43] Evaluation of high-resolution cone beam computed tomography in the detection of simulated interradicular bone lesions
    Noujeim, M.
    Prihoda, T. J.
    Langlais, R.
    Nummikoski, P.
    DENTOMAXILLOFACIAL RADIOLOGY, 2009, 38 (03) : 156 - 162
  • [44] Comparison of cone-beam computed tomography with multislice computed tomography in detection of small osseous condylar defects
    Jones, Elizabeth M.
    Papio, Melissa
    Tee, Boon Ching
    Beck, Frank M.
    Fields, Henry W.
    Sun, Zongyang
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2016, 150 (01) : 130 - 139
  • [45] Detection of periapical bone defects in human jaws using cone beam computed tomography and intraoral radiography
    Patel, S.
    Dawood, A.
    Mannocci, F.
    Wilson, R.
    Ford, T. Pitt
    INTERNATIONAL ENDODONTIC JOURNAL, 2009, 42 (06) : 507 - 515
  • [46] Cone beam computed tomography devices in the evaluation of buccal bone in anterior teeth
    Dantas, L. L.
    Ferreira, P. P.
    Oliveira, L. S. A. F.
    Neves, F. S.
    Campos, P. S. F.
    Scarfe, W. C.
    Crusoe-Rebello, I.
    AUSTRALIAN DENTAL JOURNAL, 2019, 64 (02) : 161 - 166
  • [47] Volumetric Analysis of Simulated Alveolar Cleft Defects and Bone Grafts Using Cone Beam Computed Tomography
    Amirlak, Bardia
    Tang, Cathy J.
    Becker, Devra
    Palomo, J. Martin
    Gosain, Arun K.
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2013, 131 (04) : 854 - 859
  • [48] Evaluation of a metal artifact reduction algorithm and an adaptive image noise optimization filter in the estimation of peri-implant fenestration defects using cone beam computed tomography: an in-vitro study
    Bagis, Nilsun
    Kurt, Mehmet Hakan
    Evli, Cengiz
    Camgoz, Melike
    Atakan, Cemal
    Ozturk, Hilal Peker
    Orhan, Kaan
    ORAL RADIOLOGY, 2022, 38 (03) : 325 - 335
  • [49] Evaluation of Alveolar Bone on Dental Implant Treatment using Cone Beam Computed Tomography
    Dwingadi, Edward
    Soeroso, Yuniarti
    Lessang, Robert
    Priaminiarti, Menik
    PESQUISA BRASILEIRA EM ODONTOPEDIATRIA E CLINICA INTEGRADA, 2019, 19 (01):
  • [50] Detection of alveolar bone defects with three different voxel sizes of cone-beam computed tomography: an in vitro study
    Dong, Ting
    Yuan, Lingjun
    Liu, Lu
    Qian, Yifeng
    Xia, Lunguo
    Ye, Niansong
    Fang, Bing
    SCIENTIFIC REPORTS, 2019, 9 (1)