Comparison between different cone -beam computed tomography devices in the detection of mechanically simulated peri-implant bone defects

被引:5
作者
Kim, Jun Ho [1 ]
Abdala-Junior, Reinaldo [1 ]
Munhoz, Luciana [1 ]
Cortes, Arthur Rodriguez Gonzalez [1 ,3 ]
Watanabe, Plauto Christopher Aranha [2 ]
Costa, Claudio [1 ]
Arita, Emiko Saito [1 ]
机构
[1] Univ Sao Paulo, Sch Dent, Dept Stomatol, Ave Prof Lineu Prestes 2227, BR-05508000 Sao Paulo, SP, Brazil
[2] Univ Sao Paulo, Sch Dent Ribeirao Preto, Dept Stomatol, Field Publ Oral Hlth & Forens Dent, Ribeirao Preto, Brazil
[3] Univ Malta, Mater Dei Hosp, Fac Dent Surg, Dept Dent Surg, Msida, Malta
关键词
Peri-Implantitis; Dental Implants; Cone-Beam Computed Tomography; PERIAPICAL RADIOGRAPHY; IN-VITRO; DEHISCENCE; ARTIFACTS; ACCURACY;
D O I
10.5624/isd.2020.50.2.133
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose : This study compared 2 cone-beam computed tomography (CBCT) systems in the detection of mech- anically simulated peri-implant buccal bone defects in dry human mandibles. Materials and Methods : Twenty-four implants were placed in 7 dry human mandibles. Peri-implant bone defects were created in the buccal plates of 16 implants using spherical burs. All mandibles were scanned using 2 CBCT systems with their commonly used acquisition protocols: i-CAT Gendex CB-500 (Imaging Sciences, Hatfield, PA, USA; field of view [FOV], 8 cm x 8 cm; voxel size, 0.125 mm; 120 kVp; 5 mA; 23 s) and Orthopantomograph OP300 (Intrumentarium, Tuusula, Finland; FOV, 6 cm x 8 cm; voxel size, 0.085 mm; 90 kVp; 6.3 mA; 13 s). Two oral and maxillofacial radiologists assessed the CBCT images for the presence of a defect and measured the depth of the bone defects. Diagnostic performance was compared in terms of the area under the curve (AUC), accuracy, sensitivity, specificity, and intraclass correlation coefficient. Results : High intraobserver and interobserver agreement was found (P < 0.05). The OP300 showed slightly better diagnostic performance and higher detection rates than the CB-500 (AUC, 0.56 +/- 0.03), with a mean accuracy of 75.0%, sensitivity of 81.2%, and specificity of 62.5%. Higher contrast was observed with the CB-500, whereas the OP300 formed more artifacts. Conclusion : Within the limitations of this study, the present results suggest that the choice of CBCT systems with their respective commonly used acquisition protocols does not significantly affect diagnostic performance in detecting and measuring buccal peri-implant bone loss. (Imaging Sci Dent 2020; 50: 133-9)
引用
收藏
页码:133 / 139
页数:7
相关论文
共 50 条
  • [31] Evaluation of peri-implant buccal bone by computed tomography: an experimental study
    Gonzalez-Martin, Oscar
    Oteo, Carlos
    Ortega, Ricardo
    Alandez, Javier
    Sanz, Mariano
    Veltri, Mario
    CLINICAL ORAL IMPLANTS RESEARCH, 2016, 27 (08) : 950 - 955
  • [32] Comparison of cone-beam computed tomography and digital panoramic radiography for detecting peri-implant alveolar bone changes using trabecular micro-structure analysis
    Magat, Guldane
    Oncu, Elif
    Ozcan, Sevgi
    Orhan, Kaan
    JOURNAL OF THE KOREAN ASSOCIATION OF ORAL AND MAXILLOFACIAL SURGEONS, 2022, 48 (01) : 41 - 49
  • [33] The Impact of Cone-Beam Computed Tomography Exposure Parameters on Peri-Implant Artifacts: A Literature Review
    Sawicki, Pawel
    Zawadzki, Pawel J.
    Regulski, Piotr
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (03)
  • [34] Quantitative measurement of peri-implant bone defects using optical coherence tomography
    Kim, Sulhee
    Kang, Se-Ryong
    Park, Hee-Jung
    Kim, Bome
    Kim, Tae-Il
    Yi, Won-Jin
    JOURNAL OF PERIODONTAL AND IMPLANT SCIENCE, 2018, 48 (02) : 84 - 91
  • [35] Comparison of intraoral digital radiography and cone-beam computed tomography in the measurement of periodontal bone defects
    Abdinian, Mehrdad
    Yaghini, Jaber
    Jazi, Leila
    DENTAL AND MEDICAL PROBLEMS, 2020, 57 (03) : 269 - 273
  • [36] Accuracy of peri-implant bone evaluation using cone beam CT, digital intra-oral radiographs and histology
    Ritter, L.
    Elger, M. C.
    Rothamel, D.
    Fienitz, T.
    Zinser, M.
    Schwarz, F.
    Zoeller, J. E.
    DENTOMAXILLOFACIAL RADIOLOGY, 2014, 43 (06)
  • [37] Detection of Natural and Simulated Periodontal Defects Using Cone-Beam Computed Tomography and Digital Intraoral Radiography
    Misirli, Melis
    Aksoy, Secil
    Tumer, Hayriye
    Bilginaylar, Kani
    Karaoglulari, Suzan
    Berberoglu, Atilla
    Orhan, Kaan
    Icen, Murat
    JOURNAL OF CONTEMPORARY MEDICAL SCIENCES, 2022, 8 (01): : 38 - 43
  • [38] Impact of the blooming artefact on dental implant dimensions in 13 cone-beam computed tomography devices
    Wanderley, Victor Aquino
    Vasconcelos, Karla de Faria
    Leite, Andre Ferreira
    Pauwels, Ruben
    Shujaat, Sohaib
    Jacobs, Reinhilde
    Oliveira, Matheus L.
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2021, 7 (01)
  • [39] Defect morphology, bone thickness, exposure settings and examiner experience affect the diagnostic accuracy of standardized digital periapical radiographic images but not of cone beam computed tomography in the detection of peri-implant osseous defects: An in vitro study
    Pelekos, George
    Tse, Judy M. N.
    Ho, Dominic
    Tonetti, Maurizio S.
    JOURNAL OF CLINICAL PERIODONTOLOGY, 2019, 46 (12) : 1294 - 1302
  • [40] Effect of Field of View on Detection of Condyle Bone Defects Using Cone Beam Computed Tomography
    Salemi, Fatemeh
    Shokri, Abbas
    Maleki, Fatemeh Hafez
    Farhadian, Maryam
    Dashti, Gholamreza
    Ostovarrad, Farzane
    Ranjzad, Hadi
    JOURNAL OF CRANIOFACIAL SURGERY, 2016, 27 (03) : 644 - 648