Comparison between different cone -beam computed tomography devices in the detection of mechanically simulated peri-implant bone defects

被引:5
|
作者
Kim, Jun Ho [1 ]
Abdala-Junior, Reinaldo [1 ]
Munhoz, Luciana [1 ]
Cortes, Arthur Rodriguez Gonzalez [1 ,3 ]
Watanabe, Plauto Christopher Aranha [2 ]
Costa, Claudio [1 ]
Arita, Emiko Saito [1 ]
机构
[1] Univ Sao Paulo, Sch Dent, Dept Stomatol, Ave Prof Lineu Prestes 2227, BR-05508000 Sao Paulo, SP, Brazil
[2] Univ Sao Paulo, Sch Dent Ribeirao Preto, Dept Stomatol, Field Publ Oral Hlth & Forens Dent, Ribeirao Preto, Brazil
[3] Univ Malta, Mater Dei Hosp, Fac Dent Surg, Dept Dent Surg, Msida, Malta
关键词
Peri-Implantitis; Dental Implants; Cone-Beam Computed Tomography; PERIAPICAL RADIOGRAPHY; IN-VITRO; DEHISCENCE; ARTIFACTS; ACCURACY;
D O I
10.5624/isd.2020.50.2.133
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose : This study compared 2 cone-beam computed tomography (CBCT) systems in the detection of mech- anically simulated peri-implant buccal bone defects in dry human mandibles. Materials and Methods : Twenty-four implants were placed in 7 dry human mandibles. Peri-implant bone defects were created in the buccal plates of 16 implants using spherical burs. All mandibles were scanned using 2 CBCT systems with their commonly used acquisition protocols: i-CAT Gendex CB-500 (Imaging Sciences, Hatfield, PA, USA; field of view [FOV], 8 cm x 8 cm; voxel size, 0.125 mm; 120 kVp; 5 mA; 23 s) and Orthopantomograph OP300 (Intrumentarium, Tuusula, Finland; FOV, 6 cm x 8 cm; voxel size, 0.085 mm; 90 kVp; 6.3 mA; 13 s). Two oral and maxillofacial radiologists assessed the CBCT images for the presence of a defect and measured the depth of the bone defects. Diagnostic performance was compared in terms of the area under the curve (AUC), accuracy, sensitivity, specificity, and intraclass correlation coefficient. Results : High intraobserver and interobserver agreement was found (P < 0.05). The OP300 showed slightly better diagnostic performance and higher detection rates than the CB-500 (AUC, 0.56 +/- 0.03), with a mean accuracy of 75.0%, sensitivity of 81.2%, and specificity of 62.5%. Higher contrast was observed with the CB-500, whereas the OP300 formed more artifacts. Conclusion : Within the limitations of this study, the present results suggest that the choice of CBCT systems with their respective commonly used acquisition protocols does not significantly affect diagnostic performance in detecting and measuring buccal peri-implant bone loss. (Imaging Sci Dent 2020; 50: 133-9)
引用
收藏
页码:133 / 139
页数:7
相关论文
共 50 条
  • [21] Peri-implant assessment via cone beam computed tomography and digital periapical radiography: an ex vivo study
    Silveira-Neto, Nicolau
    Flores, Mateus Ericson
    De Carli, Joao Paulo
    Costa, Max Doria
    Matos, Felipe de Souza
    Paranhos, Luiz Renato
    Sandini Linden, Maria Salete
    CLINICS, 2017, 72 (11) : 708 - 713
  • [22] Accuracy evaluation of cone beam computed tomography applied to measure peri-implant bone thickness in living patients: an ex vivo and in vivo experiment
    Lan, Yanhua
    Huang, Xiaoyuan
    Fan, Mingxing
    Yu, Huazhen
    Xie, Zhijian
    Zhou, Yiqun
    CLINICAL ORAL INVESTIGATIONS, 2022, 26 (10) : 6347 - 6359
  • [23] Comprehensive peri-implant tissue evaluation with ultrasonography and cone-beam computed tomography: A pilot study
    Siqueira, Rafael
    Sinjab, Khaled
    Pan, Ying-Chun
    Soki, Fabiana
    Chan, Hsun-Liang
    Kripfgans, Oliver
    CLINICAL ORAL IMPLANTS RESEARCH, 2021, 32 (07) : 777 - 785
  • [24] Efficacy of a cone beam computed tomography metal artifact reduction algorithm for the detection of peri-implant fenestrations and dehiscences
    Lins de-Azevedo-Vaz, Sergio
    Peyneau, Priscila Dias
    Ramirez-Sotelo, Laura Ricardina
    Vasconcelos, Karla de Faria
    Flores Campos, Paulo Sergio
    Haiter-Neto, Francisco
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2016, 121 (05): : 550 - 556
  • [25] Measurement of Peri-Implant Bone Width with and without Metal Artifact Reduction Algorithm Using Two Cone-Beam Computed Tomography Software Programs
    Hedayatipanah, Morad
    Salemi, Fatemeh
    Kamyari, Naser
    Yalpanian, Ashkan
    PESQUISA BRASILEIRA EM ODONTOPEDIATRIA E CLINICA INTEGRADA, 2021, 21
  • [26] Efficacy of low-dose cone beam computed tomography and metal artifact reduction tool for assessment of peri-implant bone defects: an in vitro study
    Alaa Shafiek Nomier
    Yousria Salah El-Din Gaweesh
    Maha R. Taalab
    Shaimaa Abu El Sadat
    BMC Oral Health, 22
  • [27] Accuracy evaluation of cone beam computed tomography applied to measure peri-implant bone thickness in living patients: an ex vivo and in vivo experiment
    Yanhua Lan
    Xiaoyuan Huang
    Mingxing Fan
    Huazhen Yu
    Zhijian Xie
    Yiqun Zhou
    Clinical Oral Investigations, 2022, 26 : 6347 - 6359
  • [28] Accuracy of cone-beam computed tomography, dental magnetic resonance imaging, and intraoral radiography for detecting peri-implant bone defects at single zirconia implantsAn in vitro study
    Hilgenfeld, Tim
    Juerchott, Alexander
    Deisenhofer, Ulrich Karl
    Krisam, Johannes
    Rammelsberg, Peter
    Heiland, Sabine
    Bendszus, Martin
    Schwindling, Franz Sebastian
    CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 (09) : 922 - 930
  • [29] Comparison between cone-beam and multislice computed tomography for identification of simulated bone lesions
    Gaia, Bruno Felipe
    Oliveira de Sales, Marcelo Augusto
    Perrella, Andreia
    Fenyo-Pereira, Marlene
    Paraiso Cavalcanti, Marcelo Gusmao
    BRAZILIAN ORAL RESEARCH, 2011, 25 (04) : 362 - 368
  • [30] Evaluation of peri-implant buccal bone by computed tomography: an experimental study
    Gonzalez-Martin, Oscar
    Oteo, Carlos
    Ortega, Ricardo
    Alandez, Javier
    Sanz, Mariano
    Veltri, Mario
    CLINICAL ORAL IMPLANTS RESEARCH, 2016, 27 (08) : 950 - 955