Comparison between different cone -beam computed tomography devices in the detection of mechanically simulated peri-implant bone defects

被引:5
|
作者
Kim, Jun Ho [1 ]
Abdala-Junior, Reinaldo [1 ]
Munhoz, Luciana [1 ]
Cortes, Arthur Rodriguez Gonzalez [1 ,3 ]
Watanabe, Plauto Christopher Aranha [2 ]
Costa, Claudio [1 ]
Arita, Emiko Saito [1 ]
机构
[1] Univ Sao Paulo, Sch Dent, Dept Stomatol, Ave Prof Lineu Prestes 2227, BR-05508000 Sao Paulo, SP, Brazil
[2] Univ Sao Paulo, Sch Dent Ribeirao Preto, Dept Stomatol, Field Publ Oral Hlth & Forens Dent, Ribeirao Preto, Brazil
[3] Univ Malta, Mater Dei Hosp, Fac Dent Surg, Dept Dent Surg, Msida, Malta
关键词
Peri-Implantitis; Dental Implants; Cone-Beam Computed Tomography; PERIAPICAL RADIOGRAPHY; IN-VITRO; DEHISCENCE; ARTIFACTS; ACCURACY;
D O I
10.5624/isd.2020.50.2.133
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose : This study compared 2 cone-beam computed tomography (CBCT) systems in the detection of mech- anically simulated peri-implant buccal bone defects in dry human mandibles. Materials and Methods : Twenty-four implants were placed in 7 dry human mandibles. Peri-implant bone defects were created in the buccal plates of 16 implants using spherical burs. All mandibles were scanned using 2 CBCT systems with their commonly used acquisition protocols: i-CAT Gendex CB-500 (Imaging Sciences, Hatfield, PA, USA; field of view [FOV], 8 cm x 8 cm; voxel size, 0.125 mm; 120 kVp; 5 mA; 23 s) and Orthopantomograph OP300 (Intrumentarium, Tuusula, Finland; FOV, 6 cm x 8 cm; voxel size, 0.085 mm; 90 kVp; 6.3 mA; 13 s). Two oral and maxillofacial radiologists assessed the CBCT images for the presence of a defect and measured the depth of the bone defects. Diagnostic performance was compared in terms of the area under the curve (AUC), accuracy, sensitivity, specificity, and intraclass correlation coefficient. Results : High intraobserver and interobserver agreement was found (P < 0.05). The OP300 showed slightly better diagnostic performance and higher detection rates than the CB-500 (AUC, 0.56 +/- 0.03), with a mean accuracy of 75.0%, sensitivity of 81.2%, and specificity of 62.5%. Higher contrast was observed with the CB-500, whereas the OP300 formed more artifacts. Conclusion : Within the limitations of this study, the present results suggest that the choice of CBCT systems with their respective commonly used acquisition protocols does not significantly affect diagnostic performance in detecting and measuring buccal peri-implant bone loss. (Imaging Sci Dent 2020; 50: 133-9)
引用
收藏
页码:133 / 139
页数:7
相关论文
共 50 条
  • [11] Assessment of peri-implant defects at titanium and zirconium dioxide implants by means of periapical radiographs and cone beam computed tomography: An in-vitro examination
    Steiger-Ronay, Valerie
    Krcmaric, Zvonimir
    Schmidlin, Patrick R.
    Sahrmann, Philipp
    Wiedemeier, Daniel B.
    Benic, Goran I.
    CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 (12) : 1195 - 1201
  • [12] Intra- and inter-observer agreements in detecting peri-implant bone defects between periapical radiography and cone beam computed tomography: A clinical study
    Zhang, Chu-Nan
    Zhu, Yu
    Fan, Lin-Feng
    Zhang, Xiao
    Jiang, Yin-Hua
    Gu, Ying-Xin
    JOURNAL OF DENTAL SCIENCES, 2021, 16 (03) : 948 - 956
  • [13] Analysis of peri-implant bone defects by using cone beam computed tomography (CBCT): an integrative review
    J. A. Costa
    J. M. Mendes
    F. Salazar
    J. J. Pacheco
    P. Rompante
    M. I. Câmara
    Oral Radiology, 2023, 39 : 455 - 466
  • [14] Effect of field of view in the detection of chemically created peri-implant bone defects in bovine ribs using cone beam computed tomography: an in vitro study
    Pinheiro, Lucas Rodrigues
    Gaia, Bruno Felipe
    Oliveira de Sales, Marcelo Augusto
    Umetsubo, Otavio Shoiti
    Santos, Oseas, Jr.
    Paraiso Cavalcanti, Marcelo Gusmao
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2015, 120 (01): : 69 - 77
  • [15] Diagnostic performance of cone beam computed tomography in assessing peri-implant bone loss: A systematic review
    Pelekos, Georgios
    Acharya, Aneesha
    Tonetti, Maurizio S.
    Bornstein, Michael M.
    CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 (05) : 443 - 464
  • [16] Efficacy of low-dose cone beam computed tomography and metal artifact reduction tool for assessment of peri-implant bone defects: an in vitro study
    Nomier, Alaa Shafiek
    Gaweesh, Yousria Salah El-Din
    Taalab, Maha R. R.
    El Sadat, Shaimaa Abu
    BMC ORAL HEALTH, 2022, 22 (01)
  • [17] Zirconia implants interfere with the evaluation of peri-implant bone defects in cone beam computed tomography (CBCT) images even with artifact reduction, a pilot study
    Kuusisto, Niina
    Abushahba, Faleh
    Syrjanen, Stina
    Huumonen, Sisko
    Vallittu, Pekka
    Narhi, Timo
    DENTOMAXILLOFACIAL RADIOLOGY, 2023, 52 (08)
  • [18] Measuring peri-implant bone lesions using low-dose cone-beam computed tomography
    Leisner, Laura Christine
    Tasaka, Akinori
    Trebing, Charlotte Theresa
    Hilgenfeld, Tim
    Kosinski, Matthias Adalbert
    Kronsteiner, Dorothea
    Rammelsberg, Peter
    Schwindling, Franz Sebastian
    JOURNAL OF PROSTHODONTIC RESEARCH, 2022, 66 (02) : 326 - 332
  • [19] Comparison of the different voxel sizes in the estimation of peri-implant fenestration defects using cone beam computed tomography: an ex vivo study
    Mehmet Hakan Kurt
    Nilsun Bağış
    Cengiz Evli
    Cemal Atakan
    Kaan Orhan
    International Journal of Implant Dentistry, 6
  • [20] Detection of peri-implant bone defects with different radiographic techniques - a human cadaver study
    Kuehl, Sebastian
    Zuercher, Silvia
    Zitzmann, Nicola U.
    Filippi, Andreas
    Payer, Michael
    Dagassan-Berndt, Dorothea
    CLINICAL ORAL IMPLANTS RESEARCH, 2016, 27 (05) : 529 - 534