Comparison between different cone -beam computed tomography devices in the detection of mechanically simulated peri-implant bone defects

被引:5
|
作者
Kim, Jun Ho [1 ]
Abdala-Junior, Reinaldo [1 ]
Munhoz, Luciana [1 ]
Cortes, Arthur Rodriguez Gonzalez [1 ,3 ]
Watanabe, Plauto Christopher Aranha [2 ]
Costa, Claudio [1 ]
Arita, Emiko Saito [1 ]
机构
[1] Univ Sao Paulo, Sch Dent, Dept Stomatol, Ave Prof Lineu Prestes 2227, BR-05508000 Sao Paulo, SP, Brazil
[2] Univ Sao Paulo, Sch Dent Ribeirao Preto, Dept Stomatol, Field Publ Oral Hlth & Forens Dent, Ribeirao Preto, Brazil
[3] Univ Malta, Mater Dei Hosp, Fac Dent Surg, Dept Dent Surg, Msida, Malta
关键词
Peri-Implantitis; Dental Implants; Cone-Beam Computed Tomography; PERIAPICAL RADIOGRAPHY; IN-VITRO; DEHISCENCE; ARTIFACTS; ACCURACY;
D O I
10.5624/isd.2020.50.2.133
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose : This study compared 2 cone-beam computed tomography (CBCT) systems in the detection of mech- anically simulated peri-implant buccal bone defects in dry human mandibles. Materials and Methods : Twenty-four implants were placed in 7 dry human mandibles. Peri-implant bone defects were created in the buccal plates of 16 implants using spherical burs. All mandibles were scanned using 2 CBCT systems with their commonly used acquisition protocols: i-CAT Gendex CB-500 (Imaging Sciences, Hatfield, PA, USA; field of view [FOV], 8 cm x 8 cm; voxel size, 0.125 mm; 120 kVp; 5 mA; 23 s) and Orthopantomograph OP300 (Intrumentarium, Tuusula, Finland; FOV, 6 cm x 8 cm; voxel size, 0.085 mm; 90 kVp; 6.3 mA; 13 s). Two oral and maxillofacial radiologists assessed the CBCT images for the presence of a defect and measured the depth of the bone defects. Diagnostic performance was compared in terms of the area under the curve (AUC), accuracy, sensitivity, specificity, and intraclass correlation coefficient. Results : High intraobserver and interobserver agreement was found (P < 0.05). The OP300 showed slightly better diagnostic performance and higher detection rates than the CB-500 (AUC, 0.56 +/- 0.03), with a mean accuracy of 75.0%, sensitivity of 81.2%, and specificity of 62.5%. Higher contrast was observed with the CB-500, whereas the OP300 formed more artifacts. Conclusion : Within the limitations of this study, the present results suggest that the choice of CBCT systems with their respective commonly used acquisition protocols does not significantly affect diagnostic performance in detecting and measuring buccal peri-implant bone loss. (Imaging Sci Dent 2020; 50: 133-9)
引用
收藏
页码:133 / 139
页数:7
相关论文
共 50 条
  • [1] A comparison of cone beam computed tomography and conventional periapical radiography at detecting peri-implant bone defects
    Dave, Meetal
    Davies, Jonathan
    Wilson, Ron
    Palmer, Richard
    CLINICAL ORAL IMPLANTS RESEARCH, 2013, 24 (06) : 671 - 678
  • [2] A Comparison of Cone Beam Computed Tomography and Panoramic Radiography in the Detection of Mechanical Created Peri-implant Bone Defects
    Naje, Ahmed R.
    F-Al Drobie, Ban
    Falah, Ali
    JOURNAL OF RESEARCH IN MEDICAL AND DENTAL SCIENCE, 2019, 7 (01): : 222 - 225
  • [3] Effectiveness of Periapical Radiography Versus Cone Beam Computed Tomography with Different Kilovoltage Settings in the Detection of Chemically Created Peri-implant Bone Defects: An In Vitro Study
    Pinheiro, Lucas Rodrigues
    Scarfe, William C.
    de Oliveira Sales, Marcelo Augusto
    Gaia, Bruno Felipe
    Gonzalez Cortes, Arthur Rodriguez
    Paraiso Cavalcanti, Marcelo Gusmao
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2017, 32 (04) : 741 - 750
  • [4] Efficacy of two radiographic algorithms for detection of peri-implant bone defects on cone-beam computed tomography scans
    Yousefi, Faezeh
    Heidari, Ali
    Ehsani, Azita
    Farhadian, Maryam
    Ehsani, Marzieh
    BMC ORAL HEALTH, 2025, 25 (01):
  • [5] Analysis of peri-implant bone defects by using cone beam computed tomography (CBCT): an integrative review
    Costa, J. A.
    Mendes, J. M.
    Salazar, F.
    Pacheco, J. J.
    Rompante, P.
    Camara, M. I.
    ORAL RADIOLOGY, 2023, 39 (03) : 455 - 466
  • [6] Detection of peri-implant bone defects using cone-beam computed tomography and digital periapical radiography with parallel and oblique projection
    Saberi, Bardia Vadiati
    Khosravifard, Negar
    Ghandari, Farnaz
    Hadinezhad, Arash
    IMAGING SCIENCE IN DENTISTRY, 2019, 49 (04) : 265 - 272
  • [7] Comparison of the different voxel sizes in the estimation of peri-implant fenestration defects using cone beam computed tomography: an ex vivo study
    Kurt, Mehmet Hakan
    Bagis, Nilsun
    Evli, Cengiz
    Atakan, Cemal
    Orhan, Kaan
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2020, 6 (01)
  • [8] Effect of Cone-Beam Computed Tomography Field of View and Acquisition Frame on the Detection of Chemically Simulated Peri-Implant Bone Loss In Vitro
    Pinheiro, Lucas Rodrigues
    Scarfe, William C.
    de Oliveira Sales, Marcelo Augusto
    Gaia, Bruno Felipe
    Gonzalez Cortes, Arthur Rodriguez
    Cavalcanti, Marcelo Gusmao
    JOURNAL OF PERIODONTOLOGY, 2015, 86 (10) : 1159 - 1165
  • [9] Evaluation of peri-implant bone defects on cone-beam computed tomography and the diagnostic accuracy of detecting these defects on panoramic images
    Oshima, Takayuki
    Asaumi, Rieko
    Ogura, Shin
    Kawai, Taisuke
    IMAGING SCIENCE IN DENTISTRY, 2024, 54 (02) : 171 - 180
  • [10] Evaluation of the accuracy of cone beam computed tomography (CBCT) in the detection of peri-implant fenestration
    Gholampour, Atefeh
    Mollaei, Melika
    Ehsani, Hodis
    Ghobadi, Fatemeh
    Hosseinnataj, Abolfazl
    Yazdani, Mehdi
    BMC ORAL HEALTH, 2024, 24 (01):