摘要
A SPE-LC-MS/MS method was developed and validated for the determination of three active pharmaceutical ingredients [API A (3-([2-(diaminomethyleneamino)thiazol-4-yl]methylthio)-N'-sulfamoyl propanimid amide, API B 5-[(2 R)-2-[2-(2-ethoxyphenoxy) ethylamino]propyl]-2-methoxybenzenesulfonamide hydrochloride, API C 1-azabicyclo [2.2.2]octan-8-yl (1S)-1-phenyl-3,4-dihydro-1H-isoquinoline-2-carboxylate] in the wastewater of a chemical synthesis production facility. The SPE-LC-MS/MS method was validated in actual influent and effluent samples. Linearity, LOD, LOQ, repeatability, intermediate precision, and recovery were determined. An LOQ of 400 mu g.L-1, 1.8 mu g.L-1, and 6 mu g.L-1, repeatability of 2.5% CV, 14.8% CV, and 11.9% CV, intermediate precision of 7.8% CV, 11.0% CV, and 8.7% CV and SPE recovery of 114%, 103%, and 91% was determined for API A, B, and C, respectively, in influent. An LOQ of 400 mu g.L-1, 0.8 mu g.L-1, and 6 mu g.L-1, repeatability of 2.0% CV, 11.0% CV, and 10.9% CV, intermediate precision of 1.7% CV, 6.8% CV, and 10.2% CV and SPE recovery of 116%, 96%, and 115% was established for API A, B, and C, respectively, in effluent. Coefficients of correlation for each analyte were >0.9301 confirming the linearity of the method. The LC-MS/MS method was used for an on-going monitoring program for these pharmaceuticals in wastewater. The method development techniques, validation procedures, and results from real wastewater samples are presented in this paper.
引用
收藏
页码:2808 / 2820
页数:13
相关论文
共 50 条
  • [41] Monitoring Pharmaceuticals and Personal Care Products in Drinking Water Samples by the LC-MS/MS Method to Estimate Their Potential Health Risk
    Molnarova, Lucia
    Halesova, Tatana
    Vaclavikova, Marta
    Bosakova, Zuzana
    MOLECULES, 2023, 28 (15):
  • [42] Quantification of Pharmaceuticals and Personal Care Product Residues in Surface and Drinking Water Samples by SPE and LC-ESI-MS/MS
    Silveira, Maria Angelis K.
    Caldas, Sergiane S.
    Guilherme, Juliana R.
    Costa, Fabiane P.
    Guimaraes, Bruno de S.
    Cerqueira, Maristela B. R.
    Soares, Bruno M.
    Primel, Ednei G.
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2013, 24 (09) : 1385 - 1395
  • [43] Detection and quantification of antibiotic residues in urine samples of healthy individuals from rural and urban communities in Ghana using a validated SPE-LC-MS/MS method
    Bekoe, Samuel Oppong
    Orman, Emmanuel
    Asare-Nkansah, Samuel
    Sorensen, Anne Mette Lerbech
    Bjorklund, Erland
    Adosraku, Reimmel Kwame
    Hansen, Martin
    Styrishave, Bjarne
    SN APPLIED SCIENCES, 2020, 2 (11):
  • [44] Simultaneous Determination of Felodipine and Metoprolol in Beagle Dog Plasma by Online SPE-LC-MS/MS and Its Application in a Pharmacokinetic Study
    Chen, Meiling
    Zhou, Jiezhao
    Mei, Le
    Yu, Fanglin
    Xie, Xiangyang
    Liu, Yan
    Yang, Yang
    Li, Ying
    Mei, Xingguo
    ANALYTICAL SCIENCES, 2017, 33 (07) : 755 - 759
  • [45] Validation and application of an LC-MS/MS method for the simultaneous quantification of 13 pharmaceuticals in seawater
    Wille, Klaas
    Noppe, Herlinde
    Verheyden, Karolien
    Vanden Bussche, Julie
    De Wulf, Eric
    Van Caeter, Peter
    Janssen, Colin R.
    De Brabander, Hubert F.
    Vanhaecke, Lynn
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 397 (05) : 1797 - 1808
  • [46] Innovative hierarchical porous hydrophilic molecularly imprinted resin for high-throughput detection of perfluorocarboxylic acids in milk using 96-well plate SPE-LC-MS/MS
    Yang, Lansen
    Li, Pengfei
    Bai, Ligai
    Cao, Jiankun
    Yan, Hongyuan
    JOURNAL OF HAZARDOUS MATERIALS, 2024, 480
  • [47] Cleanup strategies and advantages in the determination of several therapeutic classes of pharmaceuticals in wastewater samples by SPE–LC–MS/MS
    M. A. Sousa
    C. Gonçalves
    E. Cunha
    J. Hajšlová
    M. F. Alpendurada
    Analytical and Bioanalytical Chemistry, 2011, 399 : 807 - 822
  • [48] Automatised on-line SPE-chiral LC-MS/MS method for the enantiomeric determination of main fluoroquinolones and their metabolites in environmental water samples
    Mejias, Carmen
    Santos, Juan Luis
    Martin, Julia
    Aparicio, Irene
    Alonso, Esteban
    MICROCHEMICAL JOURNAL, 2023, 185
  • [49] Development of fast and robust multiresidual LC-MS/MS method for determination of pharmaceuticals in soils
    Golovko, Oksana
    Koba, Olga
    Kodesova, Radka
    Fedorova, Ganna
    Kumar, Vimal
    Grabic, Roman
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2016, 23 (14) : 14068 - 14077
  • [50] A LC-MS-MS Method for Determination of Low Doxazosin Concentrations in Plasma after Oral Administration to Dogs
    Erceg, Marijana
    Cindric, Mario
    Frketic, Lidija Pozaic
    Vertzoni, Maria
    Cetina-Cizmek, Biserka
    Reppas, Christos
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2010, 48 (02) : 114 - 119