A SPE-LC-MS/MS METHOD FOR THE DETECTION OF LOW CONCENTRATIONS OF PHARMACEUTICALS IN INDUSTRIAL WASTE STREAMS

被引:1
作者
Deegan, Ann-Marie [1 ]
Cullen, Mark [1 ]
Oelgemoeller, Michael [2 ]
Nolan, Kieran [3 ]
Tobin, John [1 ]
Morrissey, Anne [1 ]
机构
[1] Dublin City Univ, Sch Biotechnol, Dublin 9, Ireland
[2] James Cook Univ, Sch Pharm & Mol Sci, Townsville, Qld 4811, Australia
[3] Dublin City Univ, Sch Chem Sci, Dublin 9, Ireland
基金
爱尔兰科学基金会;
关键词
Mass spectrometry; Pharmaceuticals; Solid phase extraction; Wastewater; LIQUID-CHROMATOGRAPHY; AQUATIC ENVIRONMENT; MASS-SPECTROMETRY; TREATMENT PLANTS; WATER; REMOVAL; DRINKING; FATE; TIME; QUANTIFICATION;
D O I
10.1080/00032719.2011.565444
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A SPE-LC-MS/MS method was developed and validated for the determination of three active pharmaceutical ingredients [API A (3-([2-(diaminomethyleneamino)thiazol-4-yl]methylthio)-N'-sulfamoyl propanimid amide, API B 5-[(2 R)-2-[2-(2-ethoxyphenoxy) ethylamino]propyl]-2-methoxybenzenesulfonamide hydrochloride, API C 1-azabicyclo [2.2.2]octan-8-yl (1S)-1-phenyl-3,4-dihydro-1H-isoquinoline-2-carboxylate] in the wastewater of a chemical synthesis production facility. The SPE-LC-MS/MS method was validated in actual influent and effluent samples. Linearity, LOD, LOQ, repeatability, intermediate precision, and recovery were determined. An LOQ of 400 mu g.L-1, 1.8 mu g.L-1, and 6 mu g.L-1, repeatability of 2.5% CV, 14.8% CV, and 11.9% CV, intermediate precision of 7.8% CV, 11.0% CV, and 8.7% CV and SPE recovery of 114%, 103%, and 91% was determined for API A, B, and C, respectively, in influent. An LOQ of 400 mu g.L-1, 0.8 mu g.L-1, and 6 mu g.L-1, repeatability of 2.0% CV, 11.0% CV, and 10.9% CV, intermediate precision of 1.7% CV, 6.8% CV, and 10.2% CV and SPE recovery of 116%, 96%, and 115% was established for API A, B, and C, respectively, in effluent. Coefficients of correlation for each analyte were >0.9301 confirming the linearity of the method. The LC-MS/MS method was used for an on-going monitoring program for these pharmaceuticals in wastewater. The method development techniques, validation procedures, and results from real wastewater samples are presented in this paper.
引用
收藏
页码:2808 / 2820
页数:13
相关论文
共 50 条
  • [31] Development of an LC-MS/MS Method for the Assessment of Selected Active Pharmaceuticals and Metabolites in Wastewaters of a Swiss University Hospital
    Daouk, Silwan
    Fleury-Souverain, Sandrine
    Daali, Youssef
    CHIMIA, 2015, 69 (11) : 684 - 689
  • [32] An advanced LC-MS/MS protocol for simultaneous detection of pharmaceuticals and personal care products in the environment
    Yao, Wenrui
    Ge, Jinfeng
    Hu, Qiaozhuan
    Ma, Jingying
    Yuan, Daohe
    Fu, Xiaoli
    Qi, Yulin
    Volmer, Dietrich A.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2023, 37 (01)
  • [33] An optimized SPE-LC-MS/MS method for antibiotics residue analysis in ground, surface and treated water samples by response surface methodology-central composite design
    Mirzaei, Roya
    Yunesian, Masoud
    Nasseri, Simin
    Gholami, Mitra
    Jalilzadeh, Esfandiyar
    Shoeibi, Shahram
    Bidshahi, Hooshang Shafieyan
    Mesdaghinia, Alireza
    JOURNAL OF ENVIRONMENTAL HEALTH SCIENCE AND ENGINEERING, 2017, 15
  • [34] Determination of pharmaceuticals in freshwater sediments using ultrasonic-assisted extraction with SPE clean-up and HPLC-DAD or LC-ESI-MS/MS detection
    Al-Khazrajy, Omar S. A.
    Boxall, Alistair B. A.
    ANALYTICAL METHODS, 2017, 9 (28) : 4190 - 4200
  • [35] Development and validation of an analytical method for determination of pharmaceuticals in fish muscle based on QuEChERS extraction and SWATH acquisition using LC-QTOF-MS/MS system
    Pena-Herrera, J. M.
    Montemurro, N.
    Barcelo, D.
    Perez, S.
    TALANTA, 2019, 199 : 370 - 379
  • [36] Determination of Anticancer Drugs in the Aquatic Environment by SPE-LC-MS/MS-A Lebanese Case Study
    Nassour, Carla
    Nabhani-Gebara, Shereen
    Barton, Stephen J.
    Barker, James
    WATER, 2023, 15 (08)
  • [37] Determination of psilocin, bufotenine, LSD and its metabolites in serum, plasma and urine by SPE-LC-MS/MS
    Rafaela Martin
    Jennifer Schürenkamp
    Angela Gasse
    Heidi Pfeiffer
    Helga Köhler
    International Journal of Legal Medicine, 2013, 127 : 593 - 601
  • [38] Method Validation for Simultaneous Quantification of Some High-risk Pesticides in Surface Water Samples by SPE-LC-MS/MS
    Chen, Feng
    Zheng, Yunxi
    Mao, Liangang
    Zhang, Lan
    Zhu, Lizhen
    Zhang, Yanning
    Jiang, Hongyun
    Liu, Xingang
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2024, 104 (05) : 979 - 991
  • [39] Determination of psilocin, bufotenine, LSD and its metabolites in serum, plasma and urine by SPE-LC-MS/MS
    Martin, Rafaela
    Schuerenkamp, Jennifer
    Gasse, Angela
    Pfeiffer, Heidi
    Koehler, Helga
    INTERNATIONAL JOURNAL OF LEGAL MEDICINE, 2013, 127 (03) : 593 - 601
  • [40] Optimization of a Modified QuEChERS Method for Multiresidue Analysis of Pharmaceuticals and Personal Care Products in Sewage and Surface Water by LC-MS/MS
    Kachhawaha, Akanksha S.
    Nagarnaik, Pranav M.
    Jadhav, Manjusha
    Pudale, Anjali
    Labhasetwar, Pawan K.
    Banerjee, Kaushik
    JOURNAL OF AOAC INTERNATIONAL, 2017, 100 (03) : 592 - 597