A SPE-LC-MS/MS METHOD FOR THE DETECTION OF LOW CONCENTRATIONS OF PHARMACEUTICALS IN INDUSTRIAL WASTE STREAMS

被引:1
作者
Deegan, Ann-Marie [1 ]
Cullen, Mark [1 ]
Oelgemoeller, Michael [2 ]
Nolan, Kieran [3 ]
Tobin, John [1 ]
Morrissey, Anne [1 ]
机构
[1] Dublin City Univ, Sch Biotechnol, Dublin 9, Ireland
[2] James Cook Univ, Sch Pharm & Mol Sci, Townsville, Qld 4811, Australia
[3] Dublin City Univ, Sch Chem Sci, Dublin 9, Ireland
基金
爱尔兰科学基金会;
关键词
Mass spectrometry; Pharmaceuticals; Solid phase extraction; Wastewater; LIQUID-CHROMATOGRAPHY; AQUATIC ENVIRONMENT; MASS-SPECTROMETRY; TREATMENT PLANTS; WATER; REMOVAL; DRINKING; FATE; TIME; QUANTIFICATION;
D O I
10.1080/00032719.2011.565444
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A SPE-LC-MS/MS method was developed and validated for the determination of three active pharmaceutical ingredients [API A (3-([2-(diaminomethyleneamino)thiazol-4-yl]methylthio)-N'-sulfamoyl propanimid amide, API B 5-[(2 R)-2-[2-(2-ethoxyphenoxy) ethylamino]propyl]-2-methoxybenzenesulfonamide hydrochloride, API C 1-azabicyclo [2.2.2]octan-8-yl (1S)-1-phenyl-3,4-dihydro-1H-isoquinoline-2-carboxylate] in the wastewater of a chemical synthesis production facility. The SPE-LC-MS/MS method was validated in actual influent and effluent samples. Linearity, LOD, LOQ, repeatability, intermediate precision, and recovery were determined. An LOQ of 400 mu g.L-1, 1.8 mu g.L-1, and 6 mu g.L-1, repeatability of 2.5% CV, 14.8% CV, and 11.9% CV, intermediate precision of 7.8% CV, 11.0% CV, and 8.7% CV and SPE recovery of 114%, 103%, and 91% was determined for API A, B, and C, respectively, in influent. An LOQ of 400 mu g.L-1, 0.8 mu g.L-1, and 6 mu g.L-1, repeatability of 2.0% CV, 11.0% CV, and 10.9% CV, intermediate precision of 1.7% CV, 6.8% CV, and 10.2% CV and SPE recovery of 116%, 96%, and 115% was established for API A, B, and C, respectively, in effluent. Coefficients of correlation for each analyte were >0.9301 confirming the linearity of the method. The LC-MS/MS method was used for an on-going monitoring program for these pharmaceuticals in wastewater. The method development techniques, validation procedures, and results from real wastewater samples are presented in this paper.
引用
收藏
页码:2808 / 2820
页数:13
相关论文
共 50 条
  • [1] Determination of antihistaminic pharmaceuticals in surface water samples by SPE-LC-MS/MS method
    Kiszkiel-Taudul, Ilona
    MICROCHEMICAL JOURNAL, 2021, 162
  • [2] Development of a Multi-Residue Method for Monitoring 44 Pharmaceuticals in Slovene Surface Water by SPE-LC-MS/MS
    Klancar, Anita
    Trontelj, Jurij
    Roskar, Robert
    WATER AIR AND SOIL POLLUTION, 2018, 229 (06)
  • [3] A Fully Automated Online SPE-LC-MS/MS Method for the Determination of 10 Pharmaceuticals in Wastewater Samples
    Belay, Masho Hilawie
    Precht, Ulrich
    Mortensen, Peter
    Marengo, Emilio
    Robotti, Elisa
    TOXICS, 2022, 10 (03)
  • [4] Cleanup strategies and advantages in the determination of several therapeutic classes of pharmaceuticals in wastewater samples by SPE-LC-MS/MS
    Sousa, M. A.
    Goncalves, C.
    Cunha, E.
    Hajslova, J.
    Alpendurada, M. F.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 399 (02) : 807 - 822
  • [5] Determination of Acetylsalicylic acid and Naproxen in waste and Tap Water of the Municipal Area of the Sukkur City by SPE-LC-MS/MS
    Mirbahar, Waheed Ali
    Talpur, Mir Munsif Ali
    Pirzada, Tajnees
    Musharraf, Syed Ghulam
    PAKISTAN JOURNAL OF ANALYTICAL & ENVIRONMENTAL CHEMISTRY, 2020, 21 (02) : 232 - 246
  • [6] An optimized and validated SPE-LC-MS/MS method for the determination of caffeine and paraxanthine in hair
    De Kesel, Pieter M. M.
    Lambert, Willy E.
    Stove, Christophe P.
    TALANTA, 2015, 144 : 62 - 70
  • [7] Development of a Multi-Residue Method for Monitoring 44 Pharmaceuticals in Slovene Surface Water by SPE-LC-MS/MS
    Anita Klančar
    Jurij Trontelj
    Robert Roškar
    Water, Air, & Soil Pollution, 2018, 229
  • [8] Standard addition method for the determination of pharmaceutical residues in drinking water by SPE-LC-MS/MS
    Cimetiere, Nicolas
    Soutrel, Isabelle
    Lemasle, Marguerite
    Laplanche, Alain
    Crocq, Andre
    ENVIRONMENTAL TECHNOLOGY, 2013, 34 (22) : 3043 - 3053
  • [9] Comparison of multiple API techniques for the simultaneous detection of microconstituents in water by on-line SPE-LC-MS/MS
    Wang, Chengtao
    Gardinali, Piero R.
    JOURNAL OF MASS SPECTROMETRY, 2012, 47 (10): : 1255 - 1268
  • [10] Sensitive detection of antidiabetic compounds and one degradation product in wastewater samples by a new SPE-LC-MS/MS method
    Iancu, Vasile-Ion
    Scutariu, Roxana-Elena
    Chiriac, Florentina-Laura
    Radu, Gabriel-Lucian
    JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING, 2021, 56 (03): : 310 - 323