Advances in cardiae surgical transfusion practices during the 1990s in a Finnish university hospital

被引:4
作者
Capraro, L
Syrjälä, M
机构
[1] Finnish Red Cross & Blood Transfus Serv, FIN-00310 Helsinki, Finland
[2] Univ Helsinki, Cent Hosp, Dept Lab, Helsinki, Finland
关键词
audit; CABG; transfusion practices;
D O I
10.1046/j.1423-0410.2001.00100.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and Objectives Recent transfusion practices in coronary artery bypass (CABG) operations in a Finnish university hospital were evaluated, utilizing the data stored automatically in hospital registers. Materials, and Methods The register-based transfusion data on all 2363 CABG patients operated on during a 2.5-year period, from 1997 to 1999, were analysed and compared with a review of surgical transfusion practices in Finland from 1993 to 1994. Results The rate of allogeneic transfusion showed a decrease from 76% in 1993-94 to 48% in the time-period January to June 1999, and the mean number of donor exposures decreased from 3.3 to 2.0 units per patient. The mean blood product purchase costs per patient almost halved from 1993-94 to 1997-99. Conclusion Hospital registers provide a good means for prompt evaluation and reporting of large-scale transfusion data. Since 1993, transfusion rates and costs in CABG operations have decreased markedly. Further development of transfusion registers is, warranted.
引用
收藏
页码:176 / 179
页数:4
相关论文
共 15 条
[1]   Evaluating the appropriateness of red blood cell transfusions: The limitations of retrospective medical record reviews [J].
Audet, AM ;
Goodnough, LT ;
Parvin, CA .
INTERNATIONAL JOURNAL FOR QUALITY IN HEALTH CARE, 1996, 8 (01) :41-49
[2]   BLOOD USE IN PATIENTS UNDERGOING REPEAT CORONARY-ARTERY BYPASS GRAFT PROCEDURES - MULTIVARIATE-ANALYSIS [J].
BRACEY, AW ;
RADOVANCEVIC, R ;
RADOVANCEVIC, B ;
MCALLISTER, HA ;
VAUGHN, WK ;
COOLEY, DA .
TRANSFUSION, 1995, 35 (10) :850-854
[3]   A STRATEGY TO REDUCE INAPPROPRIATE RED-BLOOD-CELL TRANSFUSION [J].
BRANDIS, K ;
RICHARDS, B ;
GHENT, A ;
WEINSTEIN, S .
MEDICAL JOURNAL OF AUSTRALIA, 1994, 160 (11) :721-722
[4]   On-site coagulation monitoring does not affect hemostatic outcome after cardiac surgery [J].
Capraro, L ;
Kuitunen, A ;
Salmenperä, M ;
Kekomäki, R .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2001, 45 (02) :200-206
[5]   THE VARIABILITY OF TRANSFUSION PRACTICE IN CORONARY-ARTERY BYPASS-SURGERY [J].
GOODNOUGH, LT ;
JOHNSTON, MFM ;
TOY, PTCY .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1991, 265 (01) :86-90
[6]   Transfusion policies in coronary artery bypass -: a nationwide survey in Finland [J].
Kytölä, L ;
Nuutinen, L ;
Myllylä, G .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1998, 42 (02) :178-183
[7]   THE EFFECT OF PROVIDER EDUCATION ON BLOOD UTILIZATION PRACTICES [J].
MORRISON, JC ;
SUMRALL, DD ;
CHEVALIER, SP ;
ROBINSON, SV ;
MORRISON, FS ;
WISER, WL .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1993, 169 (05) :1240-1245
[8]  
Pinkerton PH, 1998, TRANSFUSION MED, V8, P179
[9]   SAFE LIMITS OF ISOVOLEMIC HEMODILUTION AND RECOMMENDATIONS FOR ERYTHROCYTE TRANSFUSION [J].
ROBERTIE, PG ;
GRAVLEE, GP .
INTERNATIONAL ANESTHESIOLOGY CLINICS, 1990, 28 (04) :197-204
[10]  
SIRCHIA G, 1994, SAFE GOOD USE BLOOD