Physical Activity Device Reliability and Validity during Pregnancy and Postpartum

被引:17
作者
Conway, Michelle R. [1 ]
Marshall, Mallory R. [2 ]
Schlaff, Rebecca A. [3 ]
Pfeiffer, Karin A. [1 ]
Pivarnik, James M. [1 ]
机构
[1] Michigan State Univ, Dept Kinesiol, E Lansing, MI 48824 USA
[2] Samford Univ, Dept Kinesiol, Birmingham, AL USA
[3] Saginaw Valley State Univ, Dept Kinesiol, University Ctr, MI USA
关键词
EXERCISE; ACCELEROMETER; PEDOMETER; ACTIVITY MONITOR; ENERGY-EXPENDITURE; ACTIVITY MONITORS; OMRON HJ-720; VALIDATION; PEDOMETER; METAANALYSIS; ARMBAND; RISK;
D O I
10.1249/MSS.0000000000001469
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Current physical activity (PA) recommendations for women experiencing a normal pregnancy reflect recent research showing numerous health benefits for mother and offspring. However, few studies have evaluated PA devices' reliability and validity during pregnancy, because anatomical and physiological changes throughout gestation could affect an instrument's accuracy. Purpose This study aimed to determine the reliability and validity of PA devices worn on the hip, ankle, and triceps during pregnancy and postpartum. Methods Thirty-three women performed six activities of daily living and one treadmill walk at approximately 21 and 32 wk of pregnancy, and 12 wk postpartum. There were two visits at each time period, 1 wk apart. Energy expenditure (oxygen consumption) was measured by using indirect calorimetry (IC; criterion measure), whereas PA was quantified by using accelerometers and pedometers placed at the right hip and ankle and left triceps. Interclass reliability and monitor validity compared with IC in relative (mLkg(-1)min(-1)) terms were calculated using Pearson correlation. Both multitrial and single-trial intraclass reliabilities (ICC) were estimated using ANOVA to assess monitor reliability at each time period. SEM values were calculated in relative terms for each time period. Results The reliability of the devices was moderate/strong because 66% of the Pearson correlations were between 0.6 and 1.0. Multitrial ICC values were largely in the moderate/strong range because 38% of the ICC values were between 0.6 and 0.79 and 50% were between 0.8 and 1.0. The SEM values for each device between visits ranged from 7% to 23% of the mean values. Comparison between IC and devices showed that 40% and 46% of the validity coefficients were between 0.4 and 0.59 and between 0.6 and 0.79, respectively. Conclusions PA devices show moderate/strong reliability and moderate validity for measuring PA during pregnancy and postpartum.
引用
收藏
页码:617 / 623
页数:7
相关论文
共 24 条
  • [1] Physical activity and the risk of gestational diabetes mellitus: a systematic review and dose-response meta-analysis of epidemiological studies
    Aune, Dagfinn
    Sen, Abhijit
    Henriksen, Tore
    Saugstad, Ola Didrik
    Tonstad, Serena
    [J]. EUROPEAN JOURNAL OF EPIDEMIOLOGY, 2016, 31 (10) : 967 - 997
  • [2] Physical Activity and the Risk of Preeclampsia A Systematic Review and Meta-Analysis
    Aune, Dagfinn
    Saugstad, Ola Didrik
    Henriksen, Tore
    Tonstad, Serena
    [J]. EPIDEMIOLOGY, 2014, 25 (03) : 331 - 343
  • [3] Validity of physical activity monitors in adults participating in free-living activities
    Berntsen, S.
    Hageberg, R.
    Aandstad, A.
    Mowinckel, P.
    Anderssen, S. A.
    Carlsen, K-H
    Andersen, L. B.
    [J]. BRITISH JOURNAL OF SPORTS MEDICINE, 2010, 44 (09) : 657 - 664
  • [4] Physical Activity Patterns during Pregnancy
    Borodulin, Katja M.
    Evenson, Kelly R.
    Wen, Fang
    Herring, Amy H.
    Benson, Aimee M.
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2008, 40 (11) : 1901 - 1908
  • [5] Validation and reliability of two activity monitors for energy expenditure assessment
    Brazeau, Anne-Sophie
    Beaudoin, Nadia
    Belisle, Virginie
    Messier, Virginie
    Karelis, Antony D.
    Rabasa-Lhoret, Remi
    [J]. JOURNAL OF SCIENCE AND MEDICINE IN SPORT, 2016, 19 (01) : 46 - 50
  • [6] Validity and reliability of three commercially available breath-by-breath respiratory systems
    Carter, J
    Jeukendrup, AE
    [J]. EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2002, 86 (05) : 435 - 441
  • [7] Comm Obstet Practice, 2015, OBSTET GYNECOL, V126, pe135, DOI 10.1097/AOG.0000000000001214
  • [8] Accuracy of Physical Activity Monitors in Pregnant Women
    Connolly, Christopher P.
    Coe, Dawn P.
    Kendrick, Jo M.
    Bassett, David R., Jr.
    Thompson, Dixie L.
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2011, 43 (06) : 1100 - 1105
  • [9] Estimating energy expenditure using accelerometers
    Crouter, Scott E.
    Churilla, James R.
    Bassett, David R., Jr.
    [J]. EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2006, 98 (06) : 601 - 612
  • [10] Spring-levered versus piezo-electric pedometer accuracy in overweight and obese adults
    Crouter, SE
    Schneider, PL
    Bassett, DR
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2005, 37 (10) : 1673 - 1679