Physical Activity Device Reliability and Validity during Pregnancy and Postpartum

被引:17
作者
Conway, Michelle R. [1 ]
Marshall, Mallory R. [2 ]
Schlaff, Rebecca A. [3 ]
Pfeiffer, Karin A. [1 ]
Pivarnik, James M. [1 ]
机构
[1] Michigan State Univ, Dept Kinesiol, E Lansing, MI 48824 USA
[2] Samford Univ, Dept Kinesiol, Birmingham, AL USA
[3] Saginaw Valley State Univ, Dept Kinesiol, University Ctr, MI USA
关键词
EXERCISE; ACCELEROMETER; PEDOMETER; ACTIVITY MONITOR; ENERGY-EXPENDITURE; ACTIVITY MONITORS; OMRON HJ-720; VALIDATION; PEDOMETER; METAANALYSIS; ARMBAND; RISK;
D O I
10.1249/MSS.0000000000001469
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Current physical activity (PA) recommendations for women experiencing a normal pregnancy reflect recent research showing numerous health benefits for mother and offspring. However, few studies have evaluated PA devices' reliability and validity during pregnancy, because anatomical and physiological changes throughout gestation could affect an instrument's accuracy. Purpose This study aimed to determine the reliability and validity of PA devices worn on the hip, ankle, and triceps during pregnancy and postpartum. Methods Thirty-three women performed six activities of daily living and one treadmill walk at approximately 21 and 32 wk of pregnancy, and 12 wk postpartum. There were two visits at each time period, 1 wk apart. Energy expenditure (oxygen consumption) was measured by using indirect calorimetry (IC; criterion measure), whereas PA was quantified by using accelerometers and pedometers placed at the right hip and ankle and left triceps. Interclass reliability and monitor validity compared with IC in relative (mLkg(-1)min(-1)) terms were calculated using Pearson correlation. Both multitrial and single-trial intraclass reliabilities (ICC) were estimated using ANOVA to assess monitor reliability at each time period. SEM values were calculated in relative terms for each time period. Results The reliability of the devices was moderate/strong because 66% of the Pearson correlations were between 0.6 and 1.0. Multitrial ICC values were largely in the moderate/strong range because 38% of the ICC values were between 0.6 and 0.79 and 50% were between 0.8 and 1.0. The SEM values for each device between visits ranged from 7% to 23% of the mean values. Comparison between IC and devices showed that 40% and 46% of the validity coefficients were between 0.4 and 0.59 and between 0.6 and 0.79, respectively. Conclusions PA devices show moderate/strong reliability and moderate validity for measuring PA during pregnancy and postpartum.
引用
收藏
页码:617 / 623
页数:7
相关论文
共 24 条
[1]   Physical activity and the risk of gestational diabetes mellitus: a systematic review and dose-response meta-analysis of epidemiological studies [J].
Aune, Dagfinn ;
Sen, Abhijit ;
Henriksen, Tore ;
Saugstad, Ola Didrik ;
Tonstad, Serena .
EUROPEAN JOURNAL OF EPIDEMIOLOGY, 2016, 31 (10) :967-997
[2]   Physical Activity and the Risk of Preeclampsia A Systematic Review and Meta-Analysis [J].
Aune, Dagfinn ;
Saugstad, Ola Didrik ;
Henriksen, Tore ;
Tonstad, Serena .
EPIDEMIOLOGY, 2014, 25 (03) :331-343
[3]   Validity of physical activity monitors in adults participating in free-living activities [J].
Berntsen, S. ;
Hageberg, R. ;
Aandstad, A. ;
Mowinckel, P. ;
Anderssen, S. A. ;
Carlsen, K-H ;
Andersen, L. B. .
BRITISH JOURNAL OF SPORTS MEDICINE, 2010, 44 (09) :657-664
[4]   Physical Activity Patterns during Pregnancy [J].
Borodulin, Katja M. ;
Evenson, Kelly R. ;
Wen, Fang ;
Herring, Amy H. ;
Benson, Aimee M. .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2008, 40 (11) :1901-1908
[5]   Validation and reliability of two activity monitors for energy expenditure assessment [J].
Brazeau, Anne-Sophie ;
Beaudoin, Nadia ;
Belisle, Virginie ;
Messier, Virginie ;
Karelis, Antony D. ;
Rabasa-Lhoret, Remi .
JOURNAL OF SCIENCE AND MEDICINE IN SPORT, 2016, 19 (01) :46-50
[6]   Validity and reliability of three commercially available breath-by-breath respiratory systems [J].
Carter, J ;
Jeukendrup, AE .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2002, 86 (05) :435-441
[8]   Accuracy of Physical Activity Monitors in Pregnant Women [J].
Connolly, Christopher P. ;
Coe, Dawn P. ;
Kendrick, Jo M. ;
Bassett, David R., Jr. ;
Thompson, Dixie L. .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2011, 43 (06) :1100-1105
[9]   Estimating energy expenditure using accelerometers [J].
Crouter, Scott E. ;
Churilla, James R. ;
Bassett, David R., Jr. .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2006, 98 (06) :601-612
[10]   Spring-levered versus piezo-electric pedometer accuracy in overweight and obese adults [J].
Crouter, SE ;
Schneider, PL ;
Bassett, DR .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2005, 37 (10) :1673-1679