Heart valve disease: investigation by cardiovascular magnetic resonance

被引:113
作者
Myerson, Saul G. [1 ,2 ]
机构
[1] John Radcliffe Hosp, Oxford OX3 9DU, England
[2] Univ Oxford, Ctr Clin Magnet Resonance Res, Oxford, England
关键词
Cardiovascular Magnetic Resonance; Valve disease; Flow quantification; LEFT-VENTRICULAR VOLUME; PHASE-CONTRAST FLOW; AORTIC REGURGITATION; MITRAL REGURGITATION; PULMONARY VALVE; EJECTION FRACTION; BLOOD-FLOW; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; INTERSTUDY REPRODUCIBILITY; QUANTITATIVE ASSESSMENT;
D O I
10.1186/1532-429X-14-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Cardiovascular magnetic resonance (CMR) has become a valuable investigative tool in many areas of cardiac medicine. Its value in heart valve disease is less well appreciated however, particularly as echocardiography is a powerful and widely available technique in valve disease. This review highlights the added value that CMR can bring in valve disease, complementing echocardiography in many areas, but it has also become the first-line investigation in some, such as pulmonary valve disease and assessing the right ventricle. CMR has many advantages, including the ability to image in any plane, which allows full visualisation of valves and their inflow/outflow tracts, direct measurement of valve area (particularly for stenotic valves), and characterisation of the associated great vessel anatomy (e. g. the aortic root and arch in aortic valve disease). A particular strength is the ability to quantify flow, which allows accurate measurement of regurgitation, cardiac shunt volumes/ratios and differential flow volumes (e. g. left and right pulmonary arteries). Quantification of ventricular volumes and mass is vital for determining the impact of valve disease on the heart, and CMR is the 'Gold standard' for this. Limitations of the technique include partial volume effects due to image slice thickness, and a low ability to identify small, highly mobile objects (such as vegetations) due to the need to acquire images over several cardiac cycles. The review examines the advantages and disadvantages of each imaging aspect in detail, and considers how CMR can be used optimally for each valve lesion.
引用
收藏
页数:23
相关论文
共 80 条
[61]   Preoperative thresholds for pulmonary valve replacement in patients with corrected tetralogy of Fallot using cardiovascular magnetic resonance [J].
Oosterhof, Thomas ;
van Straten, Alexander ;
Vliegen, Hubert W. ;
Meijboom, Folkert J. ;
van Dijk, Arie P. J. ;
Spijkerboer, Anje M. ;
Bouma, Berto J. ;
Zwinderman, Aeilko H. ;
Hazekamp, Mark G. ;
de Roos, Albert ;
Mulder, Barbara J. M. .
CIRCULATION, 2007, 116 (05) :545-551
[62]   Absolute assessment of aortic valve stenosis by planimetry using cardiovascular magnetic resonance imaging: Comparison with transoesophageal echocardiography, transthoracic echocardiography, and cardiac catheterisation [J].
Reant, Patricia ;
Lederlin, Mathieu ;
Lafitte, Stephane ;
Serri, Karim ;
Montaudon, Michel ;
Corneloup, Olivier ;
Roudaut, Raymond ;
Laurent, Francois .
EUROPEAN JOURNAL OF RADIOLOGY, 2006, 59 (02) :276-283
[63]   PULMONARY REGURGITATION IN THE LATE POSTOPERATIVE FOLLOW-UP OF TETRALOGY OF FALLOT - VOLUMETRIC QUANTITATION BY NUCLEAR-MAGNETIC-RESONANCE VELOCITY MAPPING [J].
REBERGEN, SA ;
CHIN, JGJ ;
OTTENKAMP, J ;
VANDERWALL, EE ;
DEROOS, A .
CIRCULATION, 1993, 88 (05) :2257-2266
[64]   COMPARISON OF MAGNETIC-RESONANCE IMAGING WITH ECHOCARDIOGRAPHY AND RADIONUCLIDE ANGIOGRAPHY IN ASSESSING CARDIAC-FUNCTION AND ANATOMY FOLLOWING MUSTARD OPERATION FOR TRANSPOSITION OF THE GREAT-ARTERIES [J].
REES, S ;
SOMERVILLE, J ;
WARNES, C ;
UNDERWOOD, R ;
FIRMIN, D ;
KLIPSTEIN, R ;
LONGMORE, D .
AMERICAN JOURNAL OF CARDIOLOGY, 1988, 61 (15) :1316-1322
[65]   Magnetic Resonance-Derived 3-Dimensional Blood Flow Patterns in the Main Pulmonary Artery as a Marker of Pulmonary Hypertension and a Measure of Elevated Mean Pulmonary Arterial Pressure [J].
Reiter, Gert ;
Reiter, Ursula ;
Kovacs, Gabor ;
Kainz, Bernhard ;
Schmidt, Karin ;
Maier, Robert ;
Olschewski, Horst ;
Rienmueller, Rainer .
CIRCULATION-CARDIOVASCULAR IMAGING, 2008, 1 (01) :23-30
[66]   Variations in right ventricular outflow tract morphology following repair of congenital heart disease: Implications for percutaneous pulmonary valve implantation [J].
Schievano, Silvia ;
Coats, Louise ;
Migliavacca, Francesco ;
Norman, Wendy ;
Frigiola, Alessandra ;
Deanfield, John ;
Bonhoeffer, Philipp ;
Taylor, Andrew M. .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2007, 9 (04) :687-695
[67]   MR IMAGING OF METALLIC IMPLANTS AND MATERIALS - A COMPILATION OF THE LITERATURE [J].
SHELLOCK, FG .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 151 (04) :811-814
[68]   QUANTIFICATION OF AORTIC REGURGITATION BY MAGNETIC-RESONANCE VELOCITY MAPPING [J].
SONDERGAARD, L ;
LINDVIG, K ;
HILDEBRANDT, P ;
THOMSEN, C ;
STAHLBERG, F ;
JOEN, T ;
HENRIKSEN, O .
AMERICAN HEART JOURNAL, 1993, 125 (04) :1081-1090
[69]   MITRAL AND AORTIC VALVULAR FLOW - QUANTIFICATION WITH MR PHASE MAPPING [J].
SONDERGAARD, L ;
THOMSEN, C ;
STAHLBERG, F ;
GYMOESE, E ;
LINDVIG, K ;
HILDEBRANDT, P ;
HENRIKSEN, O .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (03) :295-302
[70]   VALVE AREA AND CARDIAC-OUTPUT IN AORTIC-STENOSIS - QUANTIFICATION BY MAGNETIC-RESONANCE VELOCITY MAPPING [J].
SONDERGAARD, L ;
HILDEBRANDT, P ;
LINDVIG, K ;
THOMSEN, C ;
STAHLBERG, F ;
KASSIS, E ;
HENRIKSEN, O .
AMERICAN HEART JOURNAL, 1993, 126 (05) :1156-1164