Diffusion-Weighted Echo Planar Imaging using MUltiplexed Sensitivity Encoding and Reverse Polarity Gradient in Head and Neck Cancer: An Initial Study

被引:14
作者
Konar, Amaresha Shridhar [1 ]
Fung, Maggie [2 ]
Paudyal, Ramesh [1 ]
Oh, Jung Hun [1 ]
Mazaheri, Yousef [1 ,3 ]
Hatzoglou, Vaios [3 ]
Shukla-Dave, Amita [1 ,3 ]
机构
[1] Mem Sloan Kettering Canc Ctr, Dept Med Phys, 1275 York Ave, New York, NY 10065 USA
[2] GE Healthcare, New York, NY USA
[3] Mem Sloan Kettering Canc Ctr, Dept Radiol, 1275 York Ave, New York, NY 10065 USA
关键词
Head and neck region; diffusion-weighted MRI; echo planar imaging; eddy current; magnetic field inhomogeneity; geometrical distortion; multiplexed sensitivity encoding; reverse-polarity gradients; SQUAMOUS-CELL CARCINOMA; CHEMORADIATION THERAPY; TREATMENT RESPONSE; MRI; COEFFICIENT; DISTORTION; DIFFERENTIATION; PREDICTION; BENIGN; MOTION;
D O I
10.18383/j.tom.2020.00014
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We aimed to compare the geometric distortion (GD) correction performance and apparent diffusion coefficient (ADC) measurements of single-shot diffusion-weighted echo-planar imaging (SS-DWEPI), multiplexed sensitivity encoding (MUSE)-DWEPI, and MUSE-DWEPI with reverse-polarity gradient (RPG) in phantoms and patients. We performed phantom studies at 3T magnetic resonance imaging (MRI) using the American College of Radiology phantom and Quantitative Imaging Biomarker Alliance DW-MRI ice-water phantom to assess GD and effect of distortion in the measurement of ADC, respectively. Institutional review board approved the prospective clinical component of this study. DW-MRI data were obtained from 11 patients with head and neck cancer using these three DW-MRI methods. Wilcoxon signed-rank (WSR) and Kruskal-Wallis (KW) tests were used to compare ADC values, and qualitative rating by radiologist between three DW-MRI methods. In the ACR phantom, GD of 0.17% was observed for the b = 0 s/mm(2) image of the MUSE-DWEPI with RPG method compared with that of 1.53% and 2.1% of MUSE-DWEPI and SS-DWEPI, respectively; The corresponding methods root-mean-square errors were 0.58, 3.37, and 5.07 mm. WSR and KW tests showed no significant difference in the ADC measurement between these three DW-MRI methods for both healthy masseter muscles and neoplasms (P>.05). We observed improvement in spatial accuracy for MUSE-DWEPI with RPG in the head and neck region with a higher correlation (R-2 = 0.791) compared with that for SS-DWEPI (R-2 = 0.707) and MUSE-DWEPI (R-2 = 0.745). MUSE-DWEPI with RPG significantly reduces the distortion compared with MUSE-DWEPI or conventional SS-DWEPI techniques, and the ADC values were similar.
引用
收藏
页码:231 / 240
页数:10
相关论文
共 49 条
  • [11] A feasible study on using multiplexed sensitivity-encoding to reduce geometric distortion in diffusion-weighted echo planar imaging
    Chen, Xinyuan
    Zhang, Ye
    Cao, Ying
    Sun, Rui
    Huang, Peng
    Xu, Yingjie
    Wang, Wenqing
    Feng, Qinfu
    Xiao, Jianping
    Yi, Junlin
    Li, Yexiong
    Dai, Jianrong
    [J]. MAGNETIC RESONANCE IMAGING, 2018, 54 : 153 - 159
  • [12] Diffusion-Weighted Imaging in Head and Neck Cancer Technique, Limitations, and Applications
    Connolly, Michael
    Srinivasan, Ashok
    [J]. MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2018, 26 (01) : 121 - +
  • [13] Role of dynamic contrast enhanced and diffusion weighted MRI in the differentiation between post treatment changes and recurrent laryngeal cancers
    Desouky, SalahEldin
    AboSeif, Shadya
    Shama, Sherif
    Gaafar, Alaa
    Gamaleldin, Omneya
    [J]. EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2015, 46 (02) : 379 - 389
  • [14] Diffusion-weighted echo planar MR imaging of the neck at 3 T using integrated shimming: comparison of MR sequence techniques for reducing artifacts caused by magnetic-field inhomogeneities
    Gatidis, Sergios
    Graf, Hansjoerg
    Weiss, Jakob
    Stemmer, Alto
    Kiefer, Berthold
    Nikolaou, Konstantin
    Notohamiprodjo, Mike
    Martirosian, Petros
    [J]. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2017, 30 (01) : 57 - 63
  • [15] Pretreatment Intra-Voxel Incoherent Motion Diffusion-Weighted Imaging (IVIM-DWI) in Predicting Induction Chemotherapy Response in Locally Advanced Hypopharyngeal Carcinoma
    Guo, Wei
    Luo, Dehong
    Lin, Meng
    Wu, Bing
    Li, Lin
    Zhao, Yanfeng
    Yang, Liang
    Zhou, Chunwu
    [J]. MEDICINE, 2016, 95 (10)
  • [16] Apparent diffusion coefficient is a prognostic factor of head and neck squamous cell carcinoma treated with radiotherapy
    Hatakenaka, Masamitsu
    Nakamura, Katsumasa
    Yabuuchi, Hidetake
    Shioyama, Yoshiyuki
    Matsuo, Yoshio
    Kamitani, Takeshi
    Yonezawa, Masato
    Yoshiura, Takashi
    Nakashima, Torahiko
    Mori, Mitsuru
    Honda, Hiroshi
    [J]. JAPANESE JOURNAL OF RADIOLOGY, 2014, 32 (02) : 80 - 89
  • [17] Prediction of treatment response in head and neck carcinomas using IVIM-DWI: Evaluation of lymph node metastasis
    Hauser, Thomas
    Essig, Marco
    Jensen, Alexandra
    Laun, Frederik B.
    Muenter, Marc
    Maier-Hein, Klaus H.
    Stieltjes, Bram
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (05) : 783 - 787
  • [18] Efficient correction of inhomogeneous static magnetic field-induced distortion in Echo Planar Imaging
    Holland, Dominic
    Kuperman, Joshua M.
    Dale, Anders M.
    [J]. NEUROIMAGE, 2010, 50 (01) : 175 - 183
  • [19] Diffusion-Weighted Imaging for Predicting and Monitoring Primary Central Nervous System Lymphoma Treatment Response
    Huang, W. -Y.
    Wen, J. -B.
    Wu, G.
    Yin, B.
    Li, J. -J.
    Geng, D. -Y.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2016, 37 (11) : 2010 - 2018
  • [20] Jemal A, 2011, CA-CANCER J CLIN, V61, P134, DOI [10.3322/caac.20107, 10.3322/caac.20115, 10.3322/caac.21492]