Diffusion-Weighted Echo Planar Imaging using MUltiplexed Sensitivity Encoding and Reverse Polarity Gradient in Head and Neck Cancer: An Initial Study

被引:14
作者
Konar, Amaresha Shridhar [1 ]
Fung, Maggie [2 ]
Paudyal, Ramesh [1 ]
Oh, Jung Hun [1 ]
Mazaheri, Yousef [1 ,3 ]
Hatzoglou, Vaios [3 ]
Shukla-Dave, Amita [1 ,3 ]
机构
[1] Mem Sloan Kettering Canc Ctr, Dept Med Phys, 1275 York Ave, New York, NY 10065 USA
[2] GE Healthcare, New York, NY USA
[3] Mem Sloan Kettering Canc Ctr, Dept Radiol, 1275 York Ave, New York, NY 10065 USA
关键词
Head and neck region; diffusion-weighted MRI; echo planar imaging; eddy current; magnetic field inhomogeneity; geometrical distortion; multiplexed sensitivity encoding; reverse-polarity gradients; SQUAMOUS-CELL CARCINOMA; CHEMORADIATION THERAPY; TREATMENT RESPONSE; MRI; COEFFICIENT; DISTORTION; DIFFERENTIATION; PREDICTION; BENIGN; MOTION;
D O I
10.18383/j.tom.2020.00014
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We aimed to compare the geometric distortion (GD) correction performance and apparent diffusion coefficient (ADC) measurements of single-shot diffusion-weighted echo-planar imaging (SS-DWEPI), multiplexed sensitivity encoding (MUSE)-DWEPI, and MUSE-DWEPI with reverse-polarity gradient (RPG) in phantoms and patients. We performed phantom studies at 3T magnetic resonance imaging (MRI) using the American College of Radiology phantom and Quantitative Imaging Biomarker Alliance DW-MRI ice-water phantom to assess GD and effect of distortion in the measurement of ADC, respectively. Institutional review board approved the prospective clinical component of this study. DW-MRI data were obtained from 11 patients with head and neck cancer using these three DW-MRI methods. Wilcoxon signed-rank (WSR) and Kruskal-Wallis (KW) tests were used to compare ADC values, and qualitative rating by radiologist between three DW-MRI methods. In the ACR phantom, GD of 0.17% was observed for the b = 0 s/mm(2) image of the MUSE-DWEPI with RPG method compared with that of 1.53% and 2.1% of MUSE-DWEPI and SS-DWEPI, respectively; The corresponding methods root-mean-square errors were 0.58, 3.37, and 5.07 mm. WSR and KW tests showed no significant difference in the ADC measurement between these three DW-MRI methods for both healthy masseter muscles and neoplasms (P>.05). We observed improvement in spatial accuracy for MUSE-DWEPI with RPG in the head and neck region with a higher correlation (R-2 = 0.791) compared with that for SS-DWEPI (R-2 = 0.707) and MUSE-DWEPI (R-2 = 0.745). MUSE-DWEPI with RPG significantly reduces the distortion compared with MUSE-DWEPI or conventional SS-DWEPI techniques, and the ADC values were similar.
引用
收藏
页码:231 / 240
页数:10
相关论文
共 49 条
  • [1] ANALYSIS AND CORRECTION OF MOTION ARTIFACTS IN-DIFFUSION WEIGHTED IMAGING
    ANDERSON, AW
    GORE, JC
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (03) : 379 - 387
  • [2] [Anonymous], RSNA ANN M CHIC IL
  • [3] Atkinson D, 2000, MAGN RESON MED, V44, P101, DOI 10.1002/1522-2594(200007)44:1<101::AID-MRM15>3.0.CO
  • [4] 2-S
  • [5] Nonlinear phase correction of navigated multi-coil diffusion images
    Atkinson, David
    Counsell, Serena
    Hajnal, Joseph V.
    Batchelor, Philip G.
    Hill, Derek L. G.
    Larkman, David J.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2006, 56 (05) : 1135 - 1139
  • [6] Diffusion-weighted imaging with navigated interleaved echo-planar imaging and a conventional gradient system
    Bammer, P
    Stollberger, R
    Augustin, M
    Simbrunner, J
    Offenbacher, H
    Kooijman, H
    Ropele, S
    Kapeller, P
    Wach, P
    Ebner, F
    Fazekas, F
    [J]. RADIOLOGY, 1999, 211 (03) : 799 - 806
  • [7] Diffusion-tensor MRI: theory, experimental design and data analysis - a technical review
    Basser, PJ
    Jones, DK
    [J]. NMR IN BIOMEDICINE, 2002, 15 (7-8) : 456 - 467
  • [8] Diffusion-weighted interleaved echo-planar imaging with a pair of orthogonal navigator echoes
    Butts, K
    deCrespigny, A
    Pauly, JM
    Moseley, M
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (05) : 763 - 770
  • [9] Diffusion-weighted magnetic resonance imaging in bladder cancer: comparison of readout-segmented and single-shot EPI techniques
    Chen, Haihu
    Chen, Luguang
    Liu, Fang
    Lu, Jianping
    Xu, Chuanliang
    Wang, Li
    [J]. CANCER IMAGING, 2019, 19 (01)
  • [10] A robust multi-shot scan strategy for high-resolution diffusion weighted MRI enabled by multiplexed sensitivity-encoding (MUSE)
    Chen, Nan-kuei
    Guidon, Arnaud
    Chang, Hing-Chiu
    Song, Allen W.
    [J]. NEUROIMAGE, 2013, 72 : 41 - 47