A wearable H-shirt for exercise ECG monitoring and individual lactate threshold computing

被引:42
作者
Sun, Fangmin [1 ]
Yi, Chenfu [1 ]
Li, Weinan [1 ]
Li, Ye [1 ]
机构
[1] Shenzhen Univ Town, Chinese Acad Sci, Shenzhen Inst Adv Technol, Key Lab Hlth Informat, 1068 Xueyuan Ave, Shenzhen 518055, Peoples R China
基金
中国国家自然科学基金; 中国博士后科学基金;
关键词
H-shirt; Wearable; Exercise ECG; Lactate threshold; Accurate; QRS-DETECTION; SENSORS; SYSTEM; COMPRESSION; ACQUISITION; SMARTPHONE; ELECTRODES; PLATFORM;
D O I
10.1016/j.compind.2017.06.004
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Millions of people worldwide are involved in daily physical exercise and fitness, which implies the growing demand for wearable devices and gadgets monitoring these activities. To ensure the comfort of exercise, wearable health monitoring devices are the most lucrative for real-time and continuous electrocardiogram (ECG) monitoring, which is essential for making individualized fitness plans and avoiding the occurrence of cardiac arrest. Moreover, the ECG monitoring data obtained are instrumental in the computation of the individual lactate threshold heart rate, which is the inflection point of the heart rate-time curve and indicates the exercise intensity level, at which the blood concentration of lactate and lactic acid begins to exponentially increase and will result in overstraining, unless the exercise efforts (running speed or muscle intensity) are temporarily reduced. The respective monitoring and overstrain warning devices have a large potential for the individual assessment of the endurance performance, as well as for prescribing intensities in the endurance training. However, the common drawbacks of commercial wearable devices used in healthcare and medical fields for continuous monitoring of ECG, electroencephalogram, respiration, temperature, SpO(2), and human activity, such as smart helmets, wearable patches, and activity-tracking bands, are motion artifacts and unstable skin-electrode contact, which jeopardize the accurate measurements during exercise. Given this, the Health shirt (H-shirt) integrated with conductive fabric ECG electrodes enabling the accurate ECG monitoring during physical exercise has been introduced and validated by the authors. In this paper, the modified design of the sports H-shirt with the lactate threshold heart rate computing is proposed and implemented. High elasticity of the H-shirt not only ensures a stable skin-electrode contact but also avoids the discomfort caused by the measurement. A highly integrated printed circuit board is used to filter, amplify, digitalize, and transmit the ECG signal sampled from the electrodes, while a high input impedance amplifier circuit is designed to improve its signal-to-noise ratio. The Bluetooth low energy (BLE) is used as the data transmission protocol between the H-shirt and the mobile phone. A mobile phone-based ECG analysis and exercise evaluation platform have been developed, which allow one to detect six types of abnormal ECG (tachycardia, bradycardia, a dropped beat, premature beat, bigeminy, and trigeminy) and individual lactate threshold, as well as to provide real-time health warning and exercise optimization hints through mobile phone Voice messages. Being powered by a 150 mAh 3.7 V lithium battery, the H-shirt operated for at least 24 h and was tested on four volunteers of both genders and age from 14 to 32 years, whose ECG and the lactate threshold heart rate values were accurately measured during their test exercise on a treadmill with running speed up to 16 km/h and used as a reference for the users to adjust their exercise intensity. The available options of adding sensors for measurement of more physiological parameters by the proposed sports H-shirt make it quite lucrative for the rehabilitation exercise monitoring. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 11
页数:11
相关论文
共 40 条
[1]   DETERMINATION OF THE ANAEROBIC THRESHOLD BY A NON-INVASIVE FIELD-TEST IN RUNNERS [J].
CONCONI, F ;
FERRARI, M ;
ZIGLIO, PG ;
DROGHETTI, P ;
CODECA, L .
JOURNAL OF APPLIED PHYSIOLOGY, 1982, 52 (04) :869-873
[2]   BIOTEX-Biosensing Textiles for Personalised Healthcare Management [J].
Coyle, Shirley ;
Lau, King-Tong ;
Moyna, Niall ;
O'Gorman, Donal ;
Diamond, Dermot ;
Di Francesco, Fabio ;
Costanzo, Daniele ;
Salvo, Pietro ;
Trivella, Maria Giovanna ;
De Rossi, Danilo Emilio ;
Taccini, Nicola ;
Paradiso, Rita ;
Porchet, Jacque-Andre ;
Ridolfi, Andrea ;
Luprano, Jean ;
Chuzel, Cyril ;
Lanier, Thierry ;
Revol-Cavalier, Frederic ;
Schoumacker, Sebastien ;
Mourier, Veronique ;
Chartier, Isabelle ;
Convert, Reynald ;
De-Moncuit, Henri ;
Bini, Christina .
IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2010, 14 (02) :364-370
[3]   An Ear-Worn Vital Signs Monitor [J].
Da He, David ;
Winokur, Eric S. ;
Sodini, Charles G. .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2015, 62 (11) :2547-2552
[4]  
Dai H., 2016, IET SIGNAL P
[5]   A Joint QRS Detection and Data Compression Scheme for Wearable Sensors [J].
Deepu, C. J. ;
Lian, Y. .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2015, 62 (01) :165-175
[6]   A 3-Lead ECG-on-Chip with QRS Detection and Lossless Compression for Wireless Sensors [J].
Deepu, Chacko John ;
Zhang, Xiaoyang ;
Heng, Chun Huat ;
Lian, Yong .
IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS II-EXPRESS BRIEFS, 2016, 63 (12) :1151-1155
[7]   A Wearable Patch to Enable Long-Term Monitoring of Environmental, Activity and Hemodynamics Variables [J].
Etemadi, Mozziyar ;
Inan, Omer T. ;
Heller, J. Alex ;
Hersek, Sinan ;
Klein, Liviu ;
Roy, Shuvo .
IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2016, 10 (02) :280-288
[8]   Lactate Threshold Concepts How Valid are They? [J].
Faude, Oliver ;
Kindermann, Wilfried ;
Meyer, Tim .
SPORTS MEDICINE, 2009, 39 (06) :469-490
[9]  
Gifari MW, 2015, 5TH INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING AND INFORMATICS 2015, P371, DOI 10.1109/ICEEI.2015.7352529
[10]   Toward Ubiquitous Healthcare Services With a Novel Efficient Cloud Platform [J].
He, Chenguang ;
Fan, Xiaomao ;
Li, Ye .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2013, 60 (01) :230-234