Localized corrosion in an electrical submergible pump (ESP)

被引:6
|
作者
Hernandez-Sandoval, J. [1 ]
Gonzalez-Lopez, R. [2 ]
Hernandez-Rodriguez, M. A. L. [1 ]
Guzman, A. M. [1 ]
机构
[1] Univ Autonoma Nuevo Leon, Fac Ingn Mecan & Elect, SUCF, San Nicolas De Los Garza 66451, Nuevo Leon, Mexico
[2] Univ Autonoma Nuevo Leon, Fac Ingn Civil, San Nicolas De Los Garza 66451, Nuevo Leon, Mexico
关键词
Pitting corrosion; Submergible pumps; Oil-extraction; Saline solution environment; Monel; DESALINATION PLANTS; FAILURE ANALYSIS; ALLOYS; BEHAVIOR;
D O I
10.1016/j.engfailanal.2015.03.021
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
A failure analysis was performed on bolts (Monel K-500) that serve to support and join critical components of an electrical submergible pump (ESP) located in a saline solution environment. Based on the experimental results, it can be concluded that pitting corrosion was the primary cause of failure. All fracture surfaces displayed an initial zone of intergranular fracture promoted by pitting corrosion and a propagation zone with transgranular fracture due to mechanical load. High concentrations of sulfur (S) and chlorine (Cl) were found on two corrosion product layers covering the bolt surface, revealing that an aggressive electrochemical reaction occurred in the stagnant environment. Under these layers, small pits of 10-30 mu m in depth were observed that initiated the cracking paths that eventually became complete fractures. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:124 / 131
页数:8
相关论文
共 50 条
  • [1] ESP - THE ELECTRICAL SUBMERSIBLE PUMP.
    Beck, Lewis
    Petroleum Engineer International, 1983, 55 (08):
  • [2] ESP - THE ELECTRICAL SUBMERSIBLE PUMP.
    Bailey, Martin C.
    Bearden, John
    Petroleum Engineer International, 1982, 54 (11):
  • [3] ESP - THE ELECTRICAL SUBMERSIBLE PUMP.
    Beavers, John
    1983, (55):
  • [4] ESP - THE ELECTRICAL SUBMERSIBLE PUMP .6. HOW THE ESP IS HANDLED, SERVICED, AND INSTALLED
    BECK, L
    PETROLEUM ENGINEER INTERNATIONAL, 1983, 55 (08): : 62 - &
  • [5] AUTOMATIC PUMP-OFF CONTROL FOR THE VARIABLE SPEED SUBMERGIBLE PUMP.
    Divine, David L.
    Society of Petroleum Engineers of AIME, (Paper) SPE, 1980,
  • [6] LOCALIZED CORROSION IN THE FLANGE AND CASING OF A SUBMERGED CARGO PUMP
    CHANG, YP
    LEE, CY
    LEE, SC
    HER, SK
    WU, JK
    CORROSION PREVENTION & CONTROL, 1994, 41 (06): : 146 - 147
  • [7] Localized corrosion in the flange and casing of a submerged cargo pump
    Chang, Y.P.
    Lee, C.Y.
    Lee, S.C.
    Her, S.K.
    Wu, J.K.
    Corrosion Prevention and Control, 1994, 41 (06): : 146 - 147
  • [8] ESP - THE ELECTRICAL SUBMERSIBLE PUMP .4. SYSTEM-DESIGN
    HALSTEAD, G
    PETROLEUM ENGINEER INTERNATIONAL, 1983, 55 (01): : 74 - &
  • [9] Heat dissipation of the Electrical Submersible Pump (ESP) installed in a subsea skid
    Martins, Jonathan Ribeiro
    Ribeiro, Daniel da Cunha
    Pereira, Fabio de Assis Ressel
    Ribeiro, Marcos Pellegrini
    Romero, Oldrich Joel
    OIL AND GAS SCIENCE AND TECHNOLOGY-REVUE D IFP ENERGIES NOUVELLES, 2020, 75
  • [10] ESP - THE ELECTRICAL SUBMERSIBLE PUMP - 3. HOW THE SYSTEM IS PROTECTED.
    Bailey, Martin C.
    Divine, David
    Petroleum Engineer International, 1982, 54 (14):