Seismic resistance capacity of beam-column connections in high-rise buildings: E-Defense shaking table test

被引:35
作者
Chung, Yu-Lin [1 ]
Nagae, Takuya [2 ]
Matsumiya, Tomohiro [3 ]
Nakashima, Masayoshi [1 ]
机构
[1] Kyoto Univ, Disaster Prevent Res Inst, Kyoto 6110011, Japan
[2] Natl Res Inst Earth Sci & Disaster Prevent, E Def, Miki, Hyogo 6730515, Japan
[3] Kinki Univ, Higashiosaka, Osaka 5775802, Japan
关键词
high-rise building; long-period ground motion; beam-to-column connection; composite action; MOMENT-RESISTING CONNECTIONS; HYBRID SIMULATION; FRAME; COMPENSATION; PERFORMANCE; RETROFIT;
D O I
10.1002/eqe.1037
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A series of E-Defense shaking table tests are conducted on a large-scale test specimen that represents a high-rise steel building. Two types of connections featuring the connection details commonly used in 1970s, in the early days of high-rise construction in Japan, are adopted: the field-welded connection consisting of welded unreinforced flanges and a bolted web type, and the shop-welded connection in which the flanges and web are all-welded to the column flange in the shop. To examine the seismic capacity of a total of 24 beam-to-column connections of the specimen, particularly when it is subjected to long-period ground motion characterized not so much by large amplitude as by very many cycles of repeated loading, the test specimen is shaken repeatedly until the connections fractured. The test results indicate that a few of the field-welded connections fractured from the bottom flange weld boundary in a relatively small cumulative rotation primarily due to the difficulties in ensuring the welding and inspection performance in the actual field welding. The shop-welded connections are able to sustain many cycles of plastic rotation, with an averaged cumulative plastic rotation of 0.86 rad. Two shop-welded connections exhibit ductile fractures but only after experiencing many cycles. The presence of RC floor slabs promotes the strain concentration at the toe of the weld access hole in the bottom flange by at least twice compared with the case without the slab, which had resulted in a decrease in the cumulative plastic rotation by about 50%. Copyright (C) 2010 John Wiley & Sons, Ltd.
引用
收藏
页码:605 / 622
页数:18
相关论文
共 38 条
[1]  
ABE K, 2009, TEST SIMULATION COMP, P50
[2]   Compensation of actuator delay and dynamics for real-time hybrid structural simulation [J].
Ahmadizadeh, M. ;
Mosqueda, G. ;
Reinhorn, A. M. .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2008, 37 (01) :21-42
[3]  
American Institute of Steel Construction, 2005, SEISM PROV STRUCT ST
[4]  
Bertero V.V., 1994, Report No. UCB/EERC-94/09
[5]   Evaluation of numerical time-integration schemes for real-time hybrid testing [J].
Bonnet, R. A. ;
Williams, M. S. ;
Blakeborough, A. .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2008, 37 (13) :1467-1490
[6]   Improving the inverse compensation method for real-time hybrid simulation through a dual compensation scheme [J].
Chen, Cheng ;
Ricles, James M. .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2009, 38 (10) :1237-1255
[7]   Real-time hybrid testing using the unconditionally stable explicit CR integration algorithm [J].
Chen, Cheng ;
Ricles, James M. ;
Marullo, Thomas M. ;
Mercan, Oya .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2009, 38 (01) :23-44
[8]  
CHUNG YL, 2008, P 14 WORLD C EARTHQ
[9]   Seismic Resistance Capacity of High-Rise Buildings Subjected to Long-Period Ground Motions: E-Defense Shaking Table Test [J].
Chung, Yu-Lin ;
Nagae, Takuya ;
Hitaka, Toko ;
Nakashima, Masayoshi .
JOURNAL OF STRUCTURAL ENGINEERING, 2010, 136 (06) :637-644
[10]   Slab effects in SMRF retrofit connection tests [J].
Civjan, SA ;
Engelhardt, MD ;
Gross, JL .
JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2001, 127 (03) :230-237