Three-month Clinical Outcomes With Static and Dynamic Cyclotorsion Correction Using the SCHWIND AMARIS

被引:27
作者
Arba-Mosquera, Samuel [1 ,2 ]
Arbelaez, Maria C. [3 ]
机构
[1] SCHWIND Eye Tech Solut, D-63801 Kleinostheim, Germany
[2] Univ Valladolid, Inst Oftalmobiol Aplicada, SCHWIND AMARIS Grp Invest Cirugia Refract & Calid, Valladolid, Spain
[3] Muscat Eye Laser Ctr, Muscat, Oman
关键词
cyclotorsion; astigmatism; aberration; wavefront; eye movements; IN-SITU KERATOMILEUSIS; WAVE-FRONT ABERRATIONS; LASER REFRACTIVE SURGERY; PHOTOREFRACTIVE KERATECTOMY; OCULAR CYCLOTORSION; OPTICAL ABERRATIONS; MYOPIC ASTIGMATISM; VISUAL PERFORMANCE; EXPECTED BENEFIT; ABLATION PROFILE;
D O I
10.1097/ICO.0b013e318207eac2
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate intraoperative static and dynamic cyclotorsions and postoperative outcomes on astigmatism and high-order aberration in astigmatic or aberrated eyes that underwent laser in situ keratomileusis treatments with advanced cyclotorsion control using the SCHWIND AMARIS. Methods: Fifty eyes (30 for aberration neutral and 20 for corneal wavefront) were treated. Treatments were planned with Custom Ablation Manager and ablations were performed using the SCHWIND AMARIS. Laser in situ keratomileusis flaps were cut with an LDV femtosecond laser. Cyclotorsional movements were evaluated for static cyclotorsion component (SCC) for mean and repeatability, and for dynamic cyclotorsion component (DCC) for mean and amplitude. Clinical outcomes were evaluated for predictability, refractive outcome, safety, and wavefront aberration. Results: Registration rates were 90% for SCC and 98% for DCC. SCC was within +/- 5 degrees in 64% of cases. Repeatability of SCC was +/- 1 degree in 88% of cases. Mean DCC was within +/- 1 degree in 98% of cases, partly compensating for SCC. DCC amplitude was within +/- 2 degrees in 84% of cases. At 3-month follow-up, 88% of eyes were within +/- 0.50 diopter (D) of astigmatism. Mean defocus was -0.06 +/- 0.24 D and astigmatism was 0.27 +/- 0.20 D. Best spectacle-corrected visual acuity improved in 42% of eyes versus 2% losing 1 line. In corneal wavefront-customized treatments, coma, trefoil, spherical aberration, and root mean square high-order magnitudes at 6-mm analysis diameter were reduced by -0.04, -0.13, -0.04, and -0.10 mu m, respectively. Conclusions: Laser in situ keratomileusis with advanced cyclotorsion compensation using the SCHWIND AMARIS is safe and predictable and yields superior visual outcomes. Refractions and applying additional nomograms, showing the excellent performance of the system.
引用
收藏
页码:951 / 957
页数:7
相关论文
共 45 条
[1]  
Alió JL, 2003, J REFRACT SURG, V19, P516
[2]  
Applegate RA, 1997, J REFRACT SURG, V13, P295
[3]  
Arba-Mosquera S, 2009, J OPTOM, V2, P182
[4]   Clinical Effects of Pure Cyclotorsional Errors during Refractive Surgery [J].
Arba-Mosquera, Samuel ;
Merayo-Lloves, Jesus ;
de Ortueta, Diego .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2008, 49 (11) :4828-4836
[5]   Analysis of optimized profiles for 'aberration-free' refractive surgery [J].
Arba-Mosquera, Samuel ;
de Ortueta, Diego .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2009, 29 (05) :535-548
[6]   The SCHWIND AMARIS total-tech laser as an all-rounder in refractive surgery [J].
Arbelaez, Maria Clara ;
Mosquera, Samuel Arba .
MIDDLE EAST AFRICAN JOURNAL OF OPHTHALMOLOGY, 2009, 16 (01) :46-53
[7]   Excimer laser correction of moderate to high astigmatism with a non-wavefront-guided aberration-free ablation profile: Six-month results [J].
Arbelaez, Maria Clara ;
Vidal, Camila ;
Arba-Mosquera, Samuel .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (10) :1789-1798
[8]   Clinical outcomes of corneal wavefront customized ablation strategies with SCHWIND CAM in LASIK treatments [J].
Arbelaez, Maria Clara ;
Vidal, Camila ;
Arba-Mosquera, Samuel .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2009, 29 (05) :487-496
[9]   Central Ablation Depth and Postoperative Refraction in Excimer Laser Myopic Correction Measured With Ultrasound, Scheimpflug, and Optical Coherence Pachymetry [J].
Arbelaez, Maria Clara ;
Vidal, Camila ;
Mosquera, Samuel Arba .
JOURNAL OF REFRACTIVE SURGERY, 2009, 25 (08) :699-708
[10]   Neural compensation for the eye's optical aberrations [J].
Artal, P ;
Chen, L ;
Fernández, EJ ;
Singer, B ;
Manzanera, S ;
Williams, DR .
JOURNAL OF VISION, 2004, 4 (04) :281-287