X-ray absorption fine structure spectrometer using a compact superconducting synchrotron radiation source

被引:8
作者
Ozutsumi, K
Handa, K
机构
[1] Ritsumeikan Univ, Fac Sci & Engn, Dept Appl Chem, Kusatsu 5258577, Japan
[2] Ritsumeikan Univ, Ctr Synchrotron Radiat, Kusatsu 5258577, Japan
关键词
D O I
10.1063/1.1630857
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We have constructed an x-ray absorption fine structure (XAFS) spectrometer at BL-4 using the compact superconducting synchrotron radiation (SR) source at Ritsumeikan University. BL-4 is simply designed and consists of a slit, a double-crystal monochromator, and two detectors. The mechanical movement of the monochromator is in the range from 15degrees to 75degrees. By using Si(220), Ge(220), and InSb(111) crystals, the XAFS spectrometer covers the K-edge absorption energies of elements from silicon to zinc under atmospheric pressure. The incident x-ray intensity is measured by an ionization chamber with a path length of 4.5 cm. The transmitted x-ray intensity after passing through a sample is monitored by either an ionization chamber with a path length of 31 cm or a scintillation counter. The steep decrease of x-ray intensities above 5 keV is characteristic of the spectrum of photons emitted from the compact SR source and the photon flux at 10 keV is two to three orders of magnitude smaller than that at 5 keV. Hence, the contamination of higher-order harmonics is negligible above 5 keV. The double-crystal monochromator should be detuned only in measuring K-edge XAFS spectra of K, Ca, and Sc by using Si(220) or Ge(220). Suitable gases for two ionization chambers are easily selected only based on the detection efficiency of He(100%), N-2(100%), N-2(85%)+Ar(15%), N-2(50%)+Ar(50%), and Ar(100%) gases. The photon flux passing through a 2 mmx9 mm aperture is estimated from the ion current of the ionization chamber. Though the values normalized to 1 mm2 are a few orders of magnitude smaller than those of BL7C at the Photon Factory, it turned out that measurements of XAFS spectra of good quality are very easy to obtain from 1.7 to 10.5 keV by using the spectrometer at BL-4. (C) 2004 American Institute of Physics.
引用
收藏
页码:111 / 118
页数:8
相关论文
共 9 条
[1]  
GARG HB, 1994, XRAY ABSORPTION BULK
[2]   X-RAY MONOCHROMATOR SYSTEM FOR USE WITH SYNCHROTRON RADIATION SOURCES [J].
GOLOVCHENKO, JA ;
LEVESQUE, RA ;
COWAN, PL .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1981, 52 (04) :509-516
[3]   Compact superconducting ring at Ritsumeikan University [J].
Iwasaki, H ;
Nakayama, Y ;
Ozutsumi, K ;
Yamamoto, Y ;
Tokunaga, Y ;
Saisho, H ;
Matsubara, T ;
Ikeda, S .
JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 :1162-1165
[4]  
Koningsberger D.C., 1988, XRAY ABSORPTION
[5]   SOFT-X-RAY BEAMLINE BL7A AT THE UVSOR [J].
MURATA, T ;
MATSUKAWA, T ;
NAOE, S ;
HORIGOME, T ;
MATSUDO, O ;
WATANABE, M .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01) :1309-1312
[6]   A DOUBLE CRYSTAL MONOCHROMATOR FOR SOFT-X-RAY BEAM LINE OF UVSOR [J].
MURATA, T ;
MATSUKAWA, T ;
MORI, M ;
OBASHI, M ;
NAOE, SI ;
TERAUCHI, H ;
NISHIHATA, Y ;
MATSUDO, O ;
YAMAZAKI, JI .
JOURNAL DE PHYSIQUE, 1986, 47 (C-8) :135-137
[7]  
NOMURA M, 1991, 911 KEK NAT LAB HIGH
[8]  
NOMURA M, 1985, 857 NAT LAB HIGH EN
[9]  
Warren E., 1969, XRAY DIFFRACTION