Dosimetric evaluation of synthetic CT generated with GANs for MRI-only proton therapy treatment planning of brain tumors

被引:45
作者
Kazemifar, Samaneh [1 ]
Montero, Ana M. Barragan [1 ,2 ]
Souris, Kevin [2 ]
Rivas, Sara T. [2 ]
Timmerman, Robert [1 ]
Park, Yang K. [1 ]
Jiang, Steve [1 ]
Geets, Xavier [2 ,4 ]
Sterpin, Edmond [2 ,3 ]
Owrangi, Amir [1 ]
机构
[1] Univ Texas Southwestern Med Ctr Dallas, Dept Radiat Oncol, Med Artificial Intelligence & Automat MAIA Lab, Dallas, TX 75390 USA
[2] Catholic Univ Louvain, Ctr Mol Imaging Radiotherapy & Oncol MIRO, Inst Rech Expt & Clin, Brussels, Belgium
[3] KULeuven, Lab Expt Radiotherapy, Dept Oncol, Leuven, Belgium
[4] Clin Univ St Luc, Dept Radiat Oncol, Brussels, Belgium
关键词
artificial intelligence; brain MRI; deep learning; GAN structure; proton therapy; synthetic CT; COMPUTED-TOMOGRAPHY GENERATION; MONTE-CARLO-SIMULATION; TREATMENT UNCERTAINTIES; ROBUST OPTIMIZATION; RADIOTHERAPY; FEASIBILITY; REGISTRATION; SENSITIVITY; ACCURACY; MARGINS;
D O I
10.1002/acm2.12856
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose The purpose of this study was to address the dosimetric accuracy of synthetic computed tomography (sCT) images of patients with brain tumor generated using a modified generative adversarial network (GAN) method, for their use in magnetic resonance imaging (MRI)-only treatment planning for proton therapy. Methods Dose volume histogram (DVH) analysis was performed on CT and sCT images of patients with brain tumor for plans generated for intensity-modulated proton therapy (IMPT). All plans were robustly optimized using a commercially available treatment planning system (RayStation, from RaySearch Laboratories) and standard robust parameters reported in the literature. The IMPT plan was then used to compute the dose on CT and sCT images for dosimetric comparison, using RayStation analytical (pencil beam) dose algorithm. We used a second, independent Monte Carlo dose calculation engine to recompute the dose on both CT and sCT images to ensure a proper analysis of the dosimetric accuracy of the sCT images. Results The results extracted from RayStation showed excellent agreement for most DVH metrics computed on the CT and sCT for the nominal case, with a mean absolute difference below 0.5% (0.3 Gy) of the prescription dose for the clinical target volume (CTV) and below 2% (1.2 Gy) for the organs at risk (OARs) considered. This demonstrates a high dosimetric accuracy for the generated sCT images, especially in the target volume. The metrics obtained from the Monte Carlo doses mostly agreed with the values extracted from RayStation for the nominal and worst-case scenarios (mean difference below 3%). Conclusions This work demonstrated the feasibility of using sCT generated with a GAN-based deep learning method for MRI-only treatment planning of patients with brain tumor in intensity-modulated proton therapy.
引用
收藏
页码:76 / 86
页数:11
相关论文
共 58 条
[1]   A patch-based pseudo-CT approach for MRI-only radiotherapy in the pelvis [J].
Andreasen, Daniel ;
Van Leemput, Koen ;
Edmund, Jens M. .
MEDICAL PHYSICS, 2016, 43 (08) :4742-4752
[2]  
[Anonymous], 2014, MED PHYS
[3]   Comparative study of algorithms for synthetic CT generation from MRI: Consequences for MRI-guided radiation planning in the pelvic region [J].
Arabi, Hossein ;
Dowling, Jason A. ;
Burgos, Ninon ;
Han, Xiao ;
Greer, Peter B. ;
Koutsouvelis, Nikolaos ;
Zaidi, Habib .
MEDICAL PHYSICS, 2018, 45 (11) :5218-5233
[4]  
Ba Jimmy, 2014, Adam: A method for stochastic optimization
[5]   Motion in radiotherapy: particle therapy [J].
Bert, C. ;
Durante, M. .
PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (16) :R113-R114
[6]  
Birgani Mohammad Javad Tahmasebi, 2017, Electron Physician, V9, P5932, DOI 10.19082/5932
[7]  
Cawley GC, 2010, J MACH LEARN RES, V11, P2079
[8]   MR image-based synthetic CT for IMRT prostate treatment planning and CBCT image-guided localization [J].
Chen, Shupeng ;
Quan, Hong ;
Qin, An ;
Yee, Seonghwan ;
Yan, Di .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (03) :236-245
[9]   MR-Only Brain Radiation Therapy: Dosimetric Evaluation of Synthetic CTs Generated by a Dilated Convolutional Neural Network [J].
Dinkla, Anna M. ;
Wolterink, Jelmer M. ;
Maspero, Matteo ;
Savenije, Mark H. F. ;
Verhoeff, Joost J. C. ;
Seravalli, Enrica ;
Isgum, Ivana ;
Seevinck, Peter R. ;
van den Berg, Cornelis A. T. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (04) :801-812
[10]   Automatic Substitute Computed Tomography Generation and Contouring for Magnetic Resonance Imaging (MRI)-Alone External Beam Radiation Therapy From Standard MRI Sequences [J].
Dowling, Jason A. ;
Sun, Jidi ;
Pichler, Peter ;
Rivest-Henault, David ;
Ghose, Soumya ;
Richardson, Haylea ;
Wratten, Chris ;
Martin, Jarad ;
Arm, Jameen ;
Best, Leah ;
Chandra, Shekhar S. ;
Fripp, Jurgen ;
Menk, Frederick W. ;
Greer, Peter B. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (05) :1144-1153