A CMOS Front-End With Integrated Magnetoresistive Sensors for Biomolecular Recognition Detection Applications

被引:27
作者
Costa, Tiago [1 ,2 ]
Cardoso, Filipe A. [3 ]
Germano, Jose [1 ]
Freitas, Paulo P. [3 ]
Piedade, Moises S. [1 ]
机构
[1] INESC ID, P-1000029 Lisbon, Portugal
[2] Columbia Univ, Dept Elect Engn, Bioelect Syst Lab, New York, NY 10027 USA
[3] INESC MN, P-1000029 Lisbon, Portugal
关键词
CMOS sensor integration; noise optimization; GMR spin-valve; magnetic nanoparticle; magnetic sensor; PLATFORM; DIODE; ARRAY;
D O I
10.1109/TBCAS.2017.2743685
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The development of giant magnetoresistive (GMR) sensors has demonstrated significant advantages in nanomedicine, particularly for ultrasensitive point-of-care diagnostics. To this end, the detection system is required to be compact, portable, and low power consuming at the same time that a maximum signal to noise ratio is maintained. This paper reports a CMOS front-end with integrated magnetoresistive sensors for biomolecular recognition detection applications. Based on the characterization of the GMR sensor's signal and noise, CMOS building blocks (i.e., current source, multiplexers, and preamplifier) were designed targeting a negligible noise when compared with the GMR sensor's noise and a low power consumption. The CMOS front-end was fabricated using AMS 0.35 mu m technology and the magnetoresistive sensors were post-fabricated on top of the CMOS chip with high yield (97.9%). Due to its low circuit noise (16 nV/root Hz) and overall equivalent magnetic noise (11.5 nT/root Hz), the full system was able to detect 250 nm magnetic nanoparticles with a circuit imposed signal-to-noise ratio degradation of only -1.4 dB. Furthermore, the low power consumption (6.5 mW) and small dimensions (7.59 mm(2)) of the presented solution guarantees the portability of the detection system allowing its usage at the point-of-care.
引用
收藏
页码:988 / 1000
页数:13
相关论文
共 33 条
[31]   A Micro-Power EEG Acquisition SoC With Integrated Feature Extraction Processor for a Chronic Seizure Detection System [J].
Verma, Naveen ;
Shoeb, Ali ;
Bohorquez, Jose ;
Dawson, Joel ;
Guttag, John ;
Chandrakasan, Anantha P. .
IEEE JOURNAL OF SOLID-STATE CIRCUITS, 2010, 45 (04) :804-816
[32]   A 60 μW 60 nV/√Hz readout front-end for portable biopotential acquisition systems [J].
Yazicioglu, Refet Firat ;
Merken, Patrick ;
Puers, Robert ;
Van Hoof, Chris .
IEEE JOURNAL OF SOLID-STATE CIRCUITS, 2007, 42 (05) :1100-1110
[33]   Giant Magnetoresistive Biosensor Array for Detecting Magnetorelaxation [J].
Zhou, Xiahan ;
Huang, Chih-Cheng ;
Hall, Drew A. .
IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2017, 11 (04) :755-764