Home blood pressure monitoring: a position statement from the Korean Society of Hypertension Home Blood Pressure Forum

被引:13
作者
Ihm, Sang-Hyun [1 ,2 ]
Park, Jae-Hyeong [3 ]
Kim, Jang Young [4 ]
Kim, Ju-Han [5 ]
Kim, Kwang-Il [6 ]
Lee, Eun Mi [7 ]
Lee, Hae-Young [8 ]
Park, Sungha [9 ,10 ]
Shin, Jinho [11 ]
Kim, Cheol-Ho [6 ]
机构
[1] Catholic Univ Korea, Coll Med, Dept Internal Med, Div Cardiol, Seoul, South Korea
[2] Catholic Univ Korea, Coll Med, Cathol Res Inst Intractable Cardiovasc Dis, Seoul, South Korea
[3] Chungnam Natl Univ, Coll Med, Chungnam Natl Univ Hosp, Dept Cardiol Internal Med, Daejeon, South Korea
[4] Yonsei Univ, Wonju Coll Med, Dept Internal Med, Div Cardiol, Wonju, South Korea
[5] Chonnam Natl Univ Hosp, Dept Cardiol, Gwangju, South Korea
[6] Seoul Natl Univ, Bundang Hosp, Dept Internal Med, Div Geriatr, Seongnam, South Korea
[7] Wonkwang Univ, Sanbon Hosp, Dept Internal Med, Div Cardiol, Gunpo, South Korea
[8] Seoul Natl Univ, Dept Internal Med, Seoul, South Korea
[9] Yonsei Univ, Coll Med, Severance Cardiovasc Hosp, Div Cardiol, Seoul, South Korea
[10] Yonsei Univ, Coll Med, Integrated Res Ctr Cerebrovasc & Cardiovasc Dis, Seoul, South Korea
[11] Hanyang Univ, Coll Med, Dept Internal Med, Div Cardiol, Seoul, South Korea
关键词
Blood pressure; Ambulatory blood pressure monitoring; Hypertension; Measurement; Prevention and control; Home blood pressure; WHITE-COAT HYPERTENSION; TARGET-ORGAN DAMAGE; VISIT-TO-VISIT; LONG-TERM RISK; MASKED HYPERTENSION; MEASURING DEVICES; CARDIOVASCULAR OUTCOMES; EUROPEAN-SOCIETY; SELF-MEASUREMENT; INTERNATIONAL DATABASE;
D O I
10.1186/s40885-022-00218-1
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Home blood pressure measurement (HBPM) has the advantage of measuring blood pressure (BP) multiple times over a long period. HBPM effectively diagnoses stress-induced transient BP elevations (i.e., white coat hypertension), insufficient BP control throughout the day (i.e., masked hypertension), and even BP variability. In most cases, HBPM may increase self-awareness of BP, increasing the compliance of treatment. Cumulative evidence has reported better improved predictive values of HBPM in cardiovascular morbidity and mortality than office BP monitoring. In this position paper, the Korean Society of Hypertension Home Blood Pressure Forum provides comprehensive information and clinical importance on HBPM.
引用
收藏
页数:22
相关论文
共 88 条
[1]   Prediction of stroke by self-measurement of blood pressure at home versus casual screening blood pressure measurement in relation to the Joint National Committee 7 classification - The Ohasama study [J].
Asayama, K ;
Ohkubo, T ;
Kikuya, M ;
Metoki, H ;
Hoshi, H ;
Hashimoto, J ;
Totsune, K ;
Satoh, H ;
Imai, Y .
STROKE, 2004, 35 (10) :2356-2361
[2]   Nocturnal blood pressure measured by home devices: evidence and perspective for clinical application [J].
Asayama, Kei ;
Fujiwara, Takeshi ;
Hoshide, Satoshi ;
Ohkubo, Takayoshi ;
Kario, Kazuomi ;
Stergiou, George S. ;
Parati, Gianfranco ;
White, William B. ;
Weber, Michael A. ;
Imai, Yutaka .
JOURNAL OF HYPERTENSION, 2019, 37 (05) :905-916
[3]   Setting Thresholds to Varying Blood Pressure Monitoring Intervals Differentially Affects Risk Estimates Associated With White-Coat and Masked Hypertension in the Population [J].
Asayama, Kei ;
Thijs, Lutgarde ;
Li, Yan ;
Gu, Yu-Mei ;
Hara, Azusa ;
Liu, Yan-Ping ;
Zhang, Zhenyu ;
Wei, Fang-Fei ;
Lujambio, Ines ;
Mena, Luis J. ;
Boggia, Jose ;
Hansen, Tine W. ;
Bjoerklund-Bodegard, Kristina ;
Nomura, Kyoko ;
Ohkubo, Takayoshi ;
Jeppesen, Jorgen ;
Torp-Pedersen, Christian ;
Dolan, Eamon ;
Stolarz-Skrzypek, Katarzyna ;
Malyutina, Sofia ;
Casiglia, Edoardo ;
Nikitin, Yuri ;
Lind, Lars ;
Luzardo, Leonella ;
Kawecka-Jaszcz, Kalina ;
Sandoya, Edgardo ;
Filipovsky, Jan ;
Maestre, Gladys E. ;
Wang, Jiguang ;
Imai, Yutaka ;
Franklin, Stanley S. ;
O'Brien, Eoin ;
Staessen, Jan A. .
HYPERTENSION, 2014, 64 (05) :935-+
[4]   Cardiovascular outcomes in the first trial of antihypertensive therapy guided by self-measured home blood pressure [J].
Asayama, Kei ;
Ohkubo, Takayoshi ;
Metoki, Hirohito ;
Obara, Taku ;
Inoue, Ryusuke ;
Kikuya, Masahiro ;
Thijs, Lutgarde ;
Staessen, Jan A. ;
Imai, Yutaka .
HYPERTENSION RESEARCH, 2012, 35 (11) :1102-1110
[5]  
Association for the Advancement of Medical Instrumentation (AAMI), 2007, 8106012007R2013 AAMI
[6]   Oscillometric measurement of systolic and diastolic blood pressures validated in a physiologic mathematical model [J].
Babbs, Charles F. .
BIOMEDICAL ENGINEERING ONLINE, 2012, 11
[7]   RETRACTED: Relationship between Clinic and Ambulatory Blood-Pressure Measurements and Mortality (Retracted article. See vol. 382, pg. 786, 2020) [J].
Banegas, J. R. ;
Ruilope, L. M. ;
de la Sierra, A. ;
Vinyoles, E. ;
Gorostidi, M. ;
de la Cruz, J. J. ;
Ruiz-Hurtado, G. ;
Segura, J. ;
Rodriguez-Artalejo, F. ;
Williams, B. .
NEW ENGLAND JOURNAL OF MEDICINE, 2018, 378 (16) :1509-1520
[8]   Validation protocols for blood pressure-measuring devices: status quo and development [J].
Beime, Beate ;
Deutsch, Cornelia ;
Gomez, Timothy ;
Zwingers, Thomas ;
Mengden, Thomas ;
Bramlage, Peter .
BLOOD PRESSURE MONITORING, 2016, 21 (01) :1-8
[9]   Accuracy of Blood Pressure Measurement Devices in Pregnancy A Systematic Review of Validation Studies [J].
Bello, Natalie A. ;
Woolley, Jonathan J. ;
Cleary, Kirsten Lawrence ;
Falzon, Louise ;
Alpert, Bruce S. ;
Oparil, Suzanne ;
Cutter, Gary ;
Wapner, Ronald ;
Muntner, Paul ;
Tita, Alan T. ;
Shimbo, Daichi .
HYPERTENSION, 2018, 71 (02) :326-335
[10]   Home versus ambulatory and office blood pressure in predicting target organ damage in hypertension: a systematic review and meta-analysis [J].
Bliziotis, Ioannis A. ;
Destounis, Antonis ;
Stergiou, George S. .
JOURNAL OF HYPERTENSION, 2012, 30 (07) :1289-1299