Pelvic Lymph Node Irradiation Including Pararectal Sentinel Nodes for Prostate Cancer Patients: Treatment Optimization Comparing Intensity Modulated X-rays, Volumetric Modulated Arc Therapy, and Intensity Modulated Proton Therapy

被引:15
作者
Vees, Hansjorg [1 ]
Dipasquale, Giovanna [1 ]
Nouet, Philippe [1 ]
Zilli, Thomas [1 ]
Cozzi, Luca [2 ]
Miralbell, Raymond [1 ]
机构
[1] Univ Hosp Geneva, Serv Radiat Oncol, Geneva, Switzerland
[2] Oncol Inst Southern Switzerland, Med Phys Unit, Bellinzona, Switzerland
关键词
IMXT; IMPT; Prostate cancer; Sentinel node; SPECT; VMAT; RADIATION-THERAPY; CONFORMAL RADIOTHERAPY; DOSE DISTRIBUTIONS; URINARY TOXICITY; PHOTON; IMRT; CONSENSUS; DELIVERY; RAPIDARC;
D O I
10.7785/tcrt.2012.500405
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
We aimed to assess the dosimetric impact of advanced delivery radiotherapy techniques using either intensity modulated x-ray beams (IMXT), volumetric modulated arc therapy (VMAT), or intensity modulated proton therapy (IMPT), for high-risk prostate cancer patients with sentinel nodes in the pararectal region. Twenty high-risk prostate cancer patients were included in a prospective trial evaluating sentinel nodes on pelvic SPECT acquisition. To be eligible for the dosimetric study, patients had to present with pararectal sentinel nodes usually not included in the clinical target volume encompassing the pelvic lymph nodes. Radiotherapy-plans including the prostate, the seminal vesicles, and the pelvic lymph nodes with the pararectal sentinel nodes were optimized for 6 eligible patients. IMXT and IMPT were delivered with 7 and 3 beams respectively and VMAT with 2 arcs. Results were assessed with Dose-Volume Histograms and predictive normal tissue complication probabilities (NTCPs) models between the three competing treatment modalities aiming to deliver a total dose of 50.4 Gy in 1.8 Gy daily fractions. Target coverage was optimized with IMPT when compared to IMXT and VMAT. Coverage of the sentinel node was slightly better with IMXT (D-98% = 57.3 +/- 5.1 Gy) when compared with VMAT (D-98% = 56.2 +/- 4.1 Gy). The irradiation of rectal, bladder, small bowel, and femoral heads volumes was significantly reduced with IMPT when compared to IMXT and VMAT. NTCPs rates for rectal and bladder >= grade-3 late toxicity were better with IMPT (0.4 +/- 0.0% and 0.0 +/- 0.0%) compared with IMXT (4.6 +/- 3.3% and 1.4 +/- 1.1%), and VMAT (4.5 +/- 4.0% and 1.6 +/- 1.6%), respectively. Acceptable dose-volume distributions and low rectal and urinary NTCPs were estimated to geometrically complex pelvic volumes such as the ones proposed in this study using IMXT, VMAT and IMPT. IMPT succeeded, however, to propose the best physical and biological treatment plans compared to both X-ray derived plans.
引用
收藏
页码:181 / 189
页数:9
相关论文
共 33 条
[1]  
A'gren-Cronqvist A. K., 1995, THESIS STOCKHOLM U
[2]   WHOLE PELVIC RADIOTHERAPY VERSUS PROSTATE ONLY RADIOTHERAPY IN THE MANAGEMENT OF LOCALLY ADVANCED OR AGGRESSIVE PROSTATE ADENOCARCINOMA [J].
Aizer, Ayal A. ;
Yu, James B. ;
McKeon, Anne M. ;
Decker, Roy H. ;
Colberg, John W. ;
Peschel, Richard E. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (05) :1344-1349
[3]   Verification of patient-specific dose distributions in proton therapy using a commercial two-dimensional ion chamber array [J].
Arjomandy, Bijan ;
Sahoo, Narayan ;
Ciangaru, George ;
Zhu, Ronald ;
Song, Xiaofei ;
Gillin, Michael .
MEDICAL PHYSICS, 2010, 37 (11) :5831-5837
[4]  
Ballare A, 2009, TUMORI J, V95, P160
[5]  
Bauman G, 2012, Clin Oncol (R Coll Radiol), V24, P461, DOI 10.1016/j.clon.2012.05.002
[6]   FITTING OF NORMAL TISSUE TOLERANCE DATA TO AN ANALYTIC-FUNCTION [J].
BURMAN, C ;
KUTCHER, GJ ;
EMAMI, B ;
GOITEIN, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 21 (01) :123-135
[7]   DOSIMETRIC STUDY OF PELVIC PROTON RADIOTHERAPY FOR HIGH-RISK PROSTATE CANCER [J].
Chera, Bhishamjit S. ;
Vargas, Carlos ;
Morris, Christopher G. ;
Louis, Debbie ;
Flampouri, Stella ;
Yeung, Daniel ;
Duvvuri, Srividya ;
Li, Zuofeng ;
Mendenhall, Nancy Price .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (04) :994-1002
[8]   Investigation of bladder dose and volume factors influencing late urinary toxicity after external beam radiotherapy for prostate cancer [J].
Cheung, M. Rex ;
Tucker, Susan L. ;
Dong, Lei ;
de Crevoisier, Renaud ;
Lee, Andrew K. ;
Frank, Steven ;
Kudchadker, Rajat J. ;
Thames, Howard ;
Mohan, Radhe ;
Kuban, Deborah .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 67 (04) :1059-1065
[9]   DOSE CALCULATION FOR PHOTON BEAMS WITH INTENSITY MODULATION GENERATED BY DYNAMIC JAW OR MULTILEAF COLLIMATIONS [J].
CHUI, CS ;
LOSASSO, T ;
SPIROU, S .
MEDICAL PHYSICS, 1994, 21 (08) :1237-1244
[10]   A treatment planning study comparing volumetric arc modulation with RapidArc and fixed field IMRT for cervix uteri radiotherapy [J].
Cozzi, Luca ;
Dinshaw, Ketayun Ardeshir ;
Shrivastava, Shyam Kishore ;
Mahantshetty, Umesh ;
Engineer, Reena ;
Deshpande, Deepak Dattatray ;
Jamema, S. V. ;
Vanetti, Eugenio ;
Clivio, Alessandro ;
Nicolini, Giorgia ;
Fogliata, Antonella .
RADIOTHERAPY AND ONCOLOGY, 2008, 89 (02) :180-191