Simultaneous quantitation of levodopa and 3-O-methyldopa in human plasma by HPLC-ESI-MS/MS: Application for a pharmacokinetic study with a levodopa/benserazide formulation

被引:19
作者
Cesar, Isabela da Costa [1 ,2 ]
Duarte Byrro, Ricardo Martins [1 ,2 ]
de Santana e Silva Cardoso, Fabiana Fernandes [2 ]
Mundim, Iram Moreira [2 ]
Teixeira, Leonardo de Souza [2 ]
da Silva, Enikson Pontes [2 ]
Gomes, Sandro Antonio [2 ]
Bonfim, Ricardo Rodrigues [2 ]
Pianetti, Gerson Antonio [1 ]
机构
[1] Univ Fed Minas Gerais, Fac Farm, Dept Prod Farmaceut, BR-31270901 Belo Horizonte, MG, Brazil
[2] Inst Ciencias Farmaceut, BR-74175100 Goiania, Go, Brazil
关键词
Levodopa; 3-O-Methyldopa; Benserazide; HPLC-ESI-MS/MS; Plasma; Pharmacokinetics; PERFORMANCE LIQUID-CHROMATOGRAPHY; TANDEM MASS-SPECTROMETRY; L-DOPA; ELECTROCHEMICAL DETECTION; RAT PLASMA; CARBIDOPA; METHYLDOPA; BENSERAZIDE; CALIBRATION; VALIDATION;
D O I
10.1016/j.jpba.2011.07.040
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive and simple method was developed for the quantitation of levodopa and its metabolite 3-O-methyldopa, in human plasma, after oral administration of tablet formulations containing levodopa (200 mg) and benserazide (50 mg). The analytes were extracted by a protein precipitation procedure, using carbidopa as an internal standard. A mobile phase consisting of 0.2% formic acid and acetonitrile (94:6, v/v) was used and chromatographic separation was achieved using ACE C(18) column (50 mm x 4.6 mm id.; 5 mu m particle size). Selected reaction monitoring was performed using the fragmentation transitions m/z 198 -> m/z 107, m/z 212 -> m/z 166 and m/z 227 -> m/z 181 for levodopa, 3-O-methyldopa and carbidopa, respectively. Calibration curves were constructed over the range 50.0-6000.0 ng/mL for levodopa and 25.0-4000.0 ng/mL for 3-O-methyldopa. The method shown to be specific, precise, accurate and provided recovery rates higher than 85% for all analytes. No matrix effect was detected in the samples. The validated method was applied in a pharmacokinetic study with a levodopa/benserazide tablet formulation in healthy volunteers. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:1094 / 1100
页数:7
相关论文
共 22 条
[11]   Quantitative analysis of levodopa, carbidopa and methyldopa in human plasma samples using HPLC-DAD combined with second-order calibration based on alternating trilinear decomposition algorithm [J].
Li, Shu-Fang ;
Wu, Hai-Long ;
Yu, Yong-Jie ;
Li, Yuan-Na ;
Nie, Jin-Fang ;
Fu, Hai-Yan ;
Yu, Ru-Qin .
TALANTA, 2010, 81 (03) :805-812
[12]   Development and validation of a semi-automated method for L-dopa and dopamine in rat plasma using electrospray LC/MS/MS [J].
Li, WL ;
Rossi, DT ;
Fountain, ST .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2000, 24 (02) :325-333
[13]   LC-MS-MS Simultaneous Determination of l-Dopa and Its Prodrug l-Dopa n-Pentyl Ester Hydrochloride in Rat Plasma [J].
Lv, Li ;
Jiang, Weizhe ;
Zhou, Songyu ;
Huang, Xingzhen ;
Shi, Xiaoxia ;
Lv, Cong ;
Wu, Lingling ;
Xu, Chongyao .
CHROMATOGRAPHIA, 2010, 72 (3-4) :239-243
[14]   Simultaneous determination of serum concentrations of levodopa, dopamine, 3-O-methyldopa and α-methyldopa by HPLC [J].
Muzzi, Chiara ;
Bertocci, Erica ;
Terzuoli, Lucia ;
Porcelli, Brunetta ;
Ciari, Ilaria ;
Pagani, Roberto ;
Guerranti, Roberto .
BIOMEDICINE & PHARMACOTHERAPY, 2008, 62 (04) :253-258
[15]   The scientific and clinical basis for the treatment of Parkinson disease (2009) [J].
Olanow, C. Warren ;
Stern, Matthew B. ;
Sethi, Kapil .
NEUROLOGY, 2009, 72 (21) :S1-S136
[16]   Treatments for Parkinson disease-past achievements and current clinical needs [J].
Poewe, Werner .
NEUROLOGY, 2009, 72 :S65-S73
[17]  
RINNE UK, 1979, NEUROLOGY, V12, P1584
[18]   SIMULTANEOUS DETERMINATION OF LEVODOPA METHYL-ESTER, LEVODOPA, 3-O-METHYLDOPA AND DOPAMINE IN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION [J].
RONDELLI, I ;
ACERBI, D ;
MARIOTTI, F ;
VENTURA, P .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1994, 653 (01) :17-23
[19]   Simultaneous determination of levodopa, carbidopa and their metabolites in human plasma and urine samples using LC-EC [J].
Sagar, KA ;
Smyth, MR .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2000, 22 (03) :613-624
[20]   Simultaneous determination of levodopa and 3-O-methyldopa in human plasma by liquid chromatography with electrochemical detection [J].
Saxer, C ;
Niina, M ;
Nakashima, A ;
Nagae, Y ;
Masuda, N .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 802 (02) :299-305