Real-time magnetic resonance imaging of fluidized beds with internals

被引:22
|
作者
Penn, Alexander [1 ,2 ,3 ]
Boyce, Christopher M. [3 ,4 ]
Conzelmann, Nicholas [3 ]
Bezinge, Gaetan [3 ]
Pruessmann, Klaas P. [1 ,2 ]
Muller, Christoph R. [3 ]
机构
[1] Swiss Fed Inst Technol, Inst Biomed Engn, Zurich, Switzerland
[2] Univ Zurich, Zurich, Switzerland
[3] Swiss Fed Inst Technol, Dept Mech & Proc Engn, Zurich, Switzerland
[4] Columbia Univ, Dept Chem Engn, New York, NY 10027 USA
基金
瑞士国家科学基金会;
关键词
Fluidized bed reactors; Magnetic resonance imaging; Multiphase flow; Internals; Gas bubbles; Defluidized hood; HEAT-TRANSFER; BUBBLE; OBJECTS; FLOW;
D O I
10.1016/j.ces.2018.12.041
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The effect of internals on the fluidization dynamics in three-dimensional (3D) cylindrical fluidized beds was studied using real-time magnetic resonance imaging. Instantaneous snapshots of particle velocity and particle position were acquired for gas velocities U below and above the minimum fluidization velocity U-mf. Below U-mf, we found local fluidization and gas bubbling in areas adjacent to an inserted horizontal tube, likely caused by the gas locally exceeding U-mf as it flows around the insert. Above U-mf, the presence of the insert in the bed affected the fluidization dynamics. The wake region above the insert exhibited a lower average particle velocity and reduced velocity fluctuations as well as a substantially reduced number and size of gas bubbles as compared to a reference bed without internals. The extent of this wake region was found to be approximately as wide as the insert, and it extended from the top of the insert to the free surface of the bed. Moreover, the presence of internals also affected the regions below the insert by showing an increased rate of bubble formation directly below the inserted tube. The present work can provide relevant information on the design of fluidized beds with internals. Moreover, the data gathered in this work can be used to validate the accuracy of 3D numerical models of gas-solid systems. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页码:117 / 123
页数:7
相关论文
共 50 条
  • [21] Real-time functional magnetic resonance imaging: methods and applications
    Weiskopf, Nikolaus
    Sitaram, Ranganatha
    Josephs, Oliver
    Veit, Ralf
    Scharnowski, Frank
    Goebel, Rainer
    Birbaumer, Niels
    Deichmann, Ralf
    Mathiak, Klaus
    MAGNETIC RESONANCE IMAGING, 2007, 25 (06) : 989 - 1003
  • [22] In vitro real-time magnetic resonance imaging for quantification of thrombosis
    Ling Yang
    Thomas Neuberger
    Keefe B. Manning
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2021, 34 : 285 - 295
  • [23] Hyperpolarised magnetic resonance for in vivo real-time metabolic imaging
    Apps, Andrew
    Lau, Justin
    Peterzan, Mark
    Neubauer, Stefan
    Tyler, Damian
    Rider, Oliver
    HEART, 2018, 104 (18) : 1484 - +
  • [24] In vitro real-time magnetic resonance imaging for quantification of thrombosis
    Yang, Ling
    Neuberger, Thomas
    Manning, Keefe B.
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2021, 34 (02) : 285 - 295
  • [25] Real-Time Magnetic Resonance Imaging: Diagnostic and Interventional Applications
    Albert C. Lardo
    Pediatric Cardiology, 2000, 21 : 80 - 98
  • [26] An approach to real-time magnetic resonance imaging for speech production
    Narayanan, S
    Nayak, K
    Lee, SB
    Byrd, D
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2004, 115 (04): : 1771 - 1776
  • [27] Real-Time Magnetic Resonance Imaging Guidance for Cardiovascular Procedures
    Horvath, Keith A.
    Li, Ming
    Mazilu, Dumitru
    Guttman, Michael A.
    McVeigh, Elliot R.
    SEMINARS IN THORACIC AND CARDIOVASCULAR SURGERY, 2007, 19 (04) : 330 - 335
  • [28] Real-time magnetic resonance imaging: Diagnostic and interventional applications
    Lardo, AC
    PEDIATRIC CARDIOLOGY, 2000, 21 (01) : 80 - 98
  • [29] Magnetic resonance imaging of single bubbles injected into incipiently fluidized beds
    Boyce, C. M.
    Penn, A.
    Lehnert, M.
    Pruessmann, K. P.
    Mueller, C. R.
    CHEMICAL ENGINEERING SCIENCE, 2019, 200 : 147 - 166
  • [30] Real-time magnetic resonance imaging investigation of resonance tuning in soprano singing
    Bresch, Erik
    Narayanan, Shrikanth
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2010, 128 (05): : EL335 - EL341