OBJECTIVE- Optimal blood pressure control in subjects with diabetes reduces cardiovascular complications. There is theoretical benefit in the assessment of central aortic waveforms including the augmentation index, which is taken as a putative index of stiffness. Transfer functions may be used to reconstruct aortic from radial pressure waveforms; however, a single generalized transfer function may not be appropriate for all patients. We aimed to evaluate the technique in subjects with diabetes. RESEARCH DESIGN AND METHODS- Simultaneous invasive central aortic and noninvasive radial waveforms were acquired in 19 subjects with type 2 diabetes, and a diabetes-specific transfer function was derived. Similar data were acquired from 38 age- and sex-matched subjects without diabetes. Central waveforms were reconstructed using a generalized transfer function in all patients and the diabetes-specific transfer function in individuals with diabetes. RESULTS- There was no difference between groups in measured central pressures. The error in generalized transfer function-derived systolic pressure was greater in individuals with diabetes (6 +/- 7 mmHg) (mean +/- SD) than without diabetes (2 +/- 8 mmHg) (P < 0.05). Errors in other parameters were no different. The diabetes-specific transfer function reduced the error in derived systolic pressure to 0 7 mmHg in individuals with diabetes-no different than that with the generalized transfer function in individuals without diabetes. The central augmentation index reconstructed by either transfer function was unrelated to that directly measured. CONCLUSIONS- A generalized transfer function is inappropriate for the derivation of central waveforms in subjects with type 2 diabetes. Errors in subjects with diabetes might be reduced with a diabetes-specific transfer function.
引用
收藏
页码:746 / 751
页数:6
相关论文
共 21 条
[1]  
[Anonymous], J AM COLL CARDIOL SB
[2]   Systemic arterial compliance is reduced in young patients with IDDM [J].
Berry, KL ;
Skyrme-Jones, RAP ;
Cameron, JD ;
O'Brien, RC ;
Meredith, IT .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1999, 276 (06) :H1839-H1845
[3]   Augmentation of central arterial pressure in type 1 diabetes [J].
Brooks, B ;
Molyneaux, L ;
Yue, DK .
DIABETES CARE, 1999, 22 (10) :1722-1727
[4]   Augmentation of central arterial pressure in Type 2 diabetes [J].
Brooks, BA ;
Molyneaux, LM ;
Yue, DK .
DIABETIC MEDICINE, 2001, 18 (05) :374-380
[5]  
Chen CH, 1997, CIRCULATION, V95, P1827
[6]   Parametric model derivation of transfer function for noninvasive estimation of aortic pressure by radial tonometry [J].
Fetics, B ;
Nevo, E ;
Chen, CH ;
Kass, DA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1999, 46 (06) :698-706
[7]   Gender-related differences in the central arterial pressure waveform [J].
Hayward, CS ;
Kelly, RP .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 30 (07) :1863-1871
[8]   Comparison of generalized and gender-specific transfer functions for the derivation of aortic waveforms [J].
Hope, SA ;
Tay, DB ;
Meredith, IT ;
Cameron, JD .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2002, 283 (03) :H1150-H1156
[9]   AN ANALYSIS OF THE RELATIONSHIP BETWEEN CENTRAL AORTIC AND PERIPHERAL UPPER LIMB PRESSURE WAVES IN MAN [J].
KARAMANOGLU, M ;
OROURKE, MF ;
AVOLIO, AP ;
KELLY, RP .
EUROPEAN HEART JOURNAL, 1993, 14 (02) :160-167
[10]   Estimation of central aortic pressure waveform by mathematical transformation of radial tonometry pressure data [J].
Lehmann, ED .
CIRCULATION, 1998, 98 (02) :186-186