MWNT/Nafion composite modified glassy carbon electrode as the voltammetric sensor for sensitive determination of 8-hydroxyquinoline in cosmetic

被引:23
|
作者
Guo, Sujuan [1 ]
Wu, Xianli [1 ]
Zhou, Jing [1 ]
Wang, Jing [1 ]
Yang, Baocheng [1 ]
Ye, Baoxian [1 ]
机构
[1] Zhengzhou Univ, Dept Chem, Zhengzhou 450001, Peoples R China
基金
中国国家自然科学基金;
关键词
8-Hydroxyquinoline; Cosmetic; Multiwall carbon nanotube; Voltammetric sensor; PERFORMANCE LIQUID-CHROMATOGRAPHY; NANOTUBES; BIOSENSORS; ROUTE; FILM;
D O I
10.1016/j.jelechem.2011.02.010
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper, a multiwall carbon nanotube/Nafion composite modified glassy carbon electrode (MWNT/Nafion/GCE) was used as a voltammetric sensor to determine 8-hydroxyquinoline (8-HQ) in cosmetic. This voltammetric sensor exhibited strong catalytic effect toward the oxidation of 8-HQ and caused an anodic peak at 0.97 V in HAc-NaAc buffer solution (0.2 M, pH 3.6). Under the optimized condition, the anodic peak current was linear with the concentration of 8-HQ in the range of 2 x 10(-8) M-1.0 x 10(-5) M. The detection limit was 9 x 10(-9) M. The practical application of MWNT/Nafion/GCE was carried out for determining 8-HQ in cosmetic sample with satisfactory results. The electrode reaction mechanism was studied by cyclic voltammetry and UV-vis spectra. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:45 / 49
页数:5
相关论文
共 50 条
  • [11] Sensitive Detection of 8-Hydroxyquinoline in Cosmetics by Using a Poly(tannic acid)-Modified Glassy Carbon Electrode
    Gao, Zhimin
    Zeng, Qiang
    Wang, Min
    Wang, Lishi
    CHEMISTRYSELECT, 2022, 7 (16):
  • [12] TiO2/MWCNT/Nafion-Modified Glassy Carbon Electrode as a Sensitive Voltammetric Sensor for the Determination of Hydrogen Peroxide
    de Oliveira, Rafael Henrique
    Goncalves, Daniel A.
    dos Reis, Diogo Duarte
    SENSORS, 2023, 23 (18)
  • [13] Voltammetric determination of sumatriptan based on a graphene/gold nanoparticles/Nafion composite modified glassy carbon electrode
    Sanghavi, Bankim J.
    Kalambate, Pramod K.
    Karna, Shashi P.
    Srivastava, Ashwini K.
    TALANTA, 2014, 120 : 1 - 9
  • [14] Electrochemical determination of 8-hydroxyquinoline in a cosmetic product on a glassy carbon electrode modified with 1-amino-2-naphthol-4-sulphonic acid
    Tabanligil Calam, Tugba
    Yilmaz, Elif Begum
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2021, 49 (01) : 1 - 20
  • [15] A New Voltammetric Sensor Based on a Glassy Carbon Electrode Modified with 8-Hydroxyquinoline-5-sulfonic Acid
    Brunetti, Barbara
    Desimoni, Elio
    ELECTROANALYSIS, 2011, 23 (05) : 1116 - 1122
  • [16] Sensitive voltammetric sensor based on Isopropanol-Nafion-PSS-GR nanocomposite modified glassy carbon electrode for determination of Clenbuterol in pork
    Wang, Ling
    Yang, Ran
    Chen, Jing
    Li, Jianjun
    Qu, Lingbo
    Harrington, Peter de B.
    FOOD CHEMISTRY, 2014, 164 : 113 - 118
  • [17] Voltammetric sensor for caffeine based on a glassy carbon electrode modified with Nafion and graphene oxide
    Fangyuan Zhao
    Fei Wang
    Weining Zhao
    Jing Zhou
    Yang Liu
    Lina Zou
    Baoxian Ye
    Microchimica Acta, 2011, 174 : 383 - 390
  • [18] Voltammetric sensor for caffeine based on a glassy carbon electrode modified with Nafion and graphene oxide
    Zhao, Fangyuan
    Wang, Fei
    Zhao, Weining
    Zhou, Jing
    Liu, Yang
    Zou, Lina
    Ye, Baoxian
    MICROCHIMICA ACTA, 2011, 174 (3-4) : 383 - 390
  • [19] Nafion-graphene composite film modified glassy carbon electrode for voltammetric determination of p-aminophenol
    Hayati Filik
    Gamze Çetintaş
    Serkan Naci Koç
    Handan Gülce
    İsmail Boz
    Russian Journal of Electrochemistry, 2014, 50 : 243 - 252
  • [20] Nafion-Graphene Composite Film Modified Glassy Carbon Electrode for Voltammetric Determination of p-Aminophenol
    Filik, Hayati
    Cetintas, Gamze
    Koc, Serkan Naci
    Gulce, Handan
    Boz, Ismail
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2014, 50 (03) : 243 - 252