MWNT/Nafion composite modified glassy carbon electrode as the voltammetric sensor for sensitive determination of 8-hydroxyquinoline in cosmetic

被引:23
|
作者
Guo, Sujuan [1 ]
Wu, Xianli [1 ]
Zhou, Jing [1 ]
Wang, Jing [1 ]
Yang, Baocheng [1 ]
Ye, Baoxian [1 ]
机构
[1] Zhengzhou Univ, Dept Chem, Zhengzhou 450001, Peoples R China
基金
中国国家自然科学基金;
关键词
8-Hydroxyquinoline; Cosmetic; Multiwall carbon nanotube; Voltammetric sensor; PERFORMANCE LIQUID-CHROMATOGRAPHY; NANOTUBES; BIOSENSORS; ROUTE; FILM;
D O I
10.1016/j.jelechem.2011.02.010
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper, a multiwall carbon nanotube/Nafion composite modified glassy carbon electrode (MWNT/Nafion/GCE) was used as a voltammetric sensor to determine 8-hydroxyquinoline (8-HQ) in cosmetic. This voltammetric sensor exhibited strong catalytic effect toward the oxidation of 8-HQ and caused an anodic peak at 0.97 V in HAc-NaAc buffer solution (0.2 M, pH 3.6). Under the optimized condition, the anodic peak current was linear with the concentration of 8-HQ in the range of 2 x 10(-8) M-1.0 x 10(-5) M. The detection limit was 9 x 10(-9) M. The practical application of MWNT/Nafion/GCE was carried out for determining 8-HQ in cosmetic sample with satisfactory results. The electrode reaction mechanism was studied by cyclic voltammetry and UV-vis spectra. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:45 / 49
页数:5
相关论文
共 50 条
  • [1] The voltammetric sensor for sensitive determination of 8-hydroxyquinoline based on MWNTs/Nafion/GCE
    Zhou Yuanyuan
    Li Song
    OPTOELECTRONICS AND ADVANCED MATERIALS-RAPID COMMUNICATIONS, 2011, 5 (09): : 924 - 927
  • [2] Sensitive Voltammetric Determination of Cadmium(II) with 8-Hydroxyquinoline and Ionic Liquid Modified Carbon Paste Electrode
    Jia, Shaohui
    Gong, Shixing
    Cheng, Yong
    Wang, Huiyun
    Liu, Hejian
    Zhang, Bo
    Sun, Wei
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2014, 61 (11) : 1217 - 1222
  • [3] APPLICATION OF GLASSY CARBON ELECTRODE MODIFIED WITH NAFION/MWCNTS FOR SENSITIVE VOLTAMMETRIC DETERMINATION OF THYMOL
    Piech, Robert
    Paczosa-Bator, Beata
    ACTA POLONIAE PHARMACEUTICA, 2015, 72 (06): : 1081 - 1088
  • [4] Lead determination on MWNT/Nafion composite modified glassy carbon electrodes
    Xu, Q
    Liu, NN
    Zhu, JJ
    CHINESE JOURNAL OF CHEMISTRY, 2005, 23 (11) : 1510 - 1514
  • [5] High Sensitive Voltammetric Determination of Paroxetine on Glassy Carbon Electrode Modified with Nafion/MWCNTs
    Piech, Robert
    Rumin, Martyna
    Paczosa-Bator, Beata
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2014, 9 (12): : 7528 - 7539
  • [6] Modified glassy carbon electrode with Nafion/MWNTs as a sensitive voltammetric sensor for the determination of paeonol in pharmaceutical and biological samples
    Yang, Suling
    Qu, Lingbo
    Yang, Ran
    Li, Jianjun
    Yu, Lanlan
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2010, 40 (07) : 1371 - 1378
  • [7] Modified glassy carbon electrode with Nafion/MWNTs as a sensitive voltammetric sensor for the determination of paeonol in pharmaceutical and biological samples
    Suling Yang
    Lingbo Qu
    Ran Yang
    Jianjun Li
    Lanlan Yu
    Journal of Applied Electrochemistry, 2010, 40 : 1371 - 1378
  • [8] Sensitive voltammetric sensor of dihydromyricetin based on Nafion/SWNT-modified glassy carbon electrode
    Xu, Ying
    Wang, Fei
    Wang, Le
    Zhao, Fangyuan
    Yang, Baocheng
    Ye, Baoxian
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2012, 16 (04) : 1473 - 1480
  • [9] Sensitive voltammetric sensor of dihydromyricetin based on Nafion/SWNT-modified glassy carbon electrode
    Ying Xu
    Fei Wang
    Le Wang
    Fangyuan Zhao
    Baocheng Yang
    Baoxian Ye
    Journal of Solid State Electrochemistry, 2012, 16 : 1473 - 1480
  • [10] Voltammetric Determination of Codeine on Glassy Carbon Electrode Modified with Nafion/MWCNTs
    Piech, Robert
    Rumin, Martyna
    Paczosa-Bator, Beata
    JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY, 2015, 2015