Totally implantable hearing system: Five-year hearing results

被引:13
作者
Shohet, Jack A. [1 ]
Kraus, Eric M. [2 ]
Catalano, Peter J. [3 ]
Toh, Elizabeth [4 ]
机构
[1] Shohet Ear Associates, 446 Old Newport Blvd, Newport Beach, CA 92663 USA
[2] Ear Ctr Greensboro, Greensboro, NC USA
[3] St Elizabeths Med Ctr, Boston, MA USA
[4] Lahey Hosp & Med Ctr, Boston, MA USA
关键词
Implants; otology; middle ear; quality of life; active middle ear implant; hearing loss; MIDDLE-EAR IMPLANT;
D O I
10.1002/lary.26602
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objectives/Hypothesis1) To provide long-term hearing outcome measures of a totally implantable hearing system (implant) and compare to the baseline unaided (BLU) and baseline aided (BLA) conditions, and 2) discuss relevant safety measures. Study DesignProspective, nonrandomized, multicenter, single-subject-as-own-control design. MethodsFifty-one subjects with mild to severe sensorineural hearing loss were implanted between 2008 and 2009 and enrolled in this postmarket approval study in the setting of private and hospital-based practices. Forty-nine of these subjects completed the 5-year study, which included annual follow-ups. Primary effectiveness endpoints were speech reception threshold (SRT) and word recognition scores at 50 dB (WRS50s). Secondary effectiveness endpoints were WRSs and the Abbreviated Profile of Hearing Aid Benefit (APHAB) scores. Adverse Device Effects (ADEs) and Serious Adverse Device Effects (SADEs) reported during the study period and a comparison of bone conduction scores are submitted as safety measures. ResultsCompared to the BLA condition, 1) SRT scores were improved at every annual follow-up; 2) WRS50s were better in 49%, and the same in 41% at the 5-year follow-up; 3) WRSs were improved by 17% at the 5-year follow-up; and 4) APHAB scores were improved in most subscales at every annual follow-up. There were three SADEs in three subjects and 15 ADEs in 11 subjects. Bone conduction scores increased by 3.7 dB at the 5-year follow-up. Average battery life was 4.9 years. ConclusionsThe implant compared favorably to the subjects' hearing aid throughout the 5-year period in all of the areas measured and was found to be safe. Level of Evidence2b. Laryngoscope, 128:210-216, 2018
引用
收藏
页码:210 / 216
页数:7
相关论文
共 50 条
  • [41] Vibrant Soundbridge implant: A new hearing prosthesis for patients with sensorineural hearing loss; Part 1 - Principle of the Soundbridge system and initial clinical results.
    Lenarz, T
    Weber, BP
    Mack, KF
    Battmer, RD
    Gnadeberg, D
    [J]. LARYNGO-RHINO-OTOLOGIE, 1998, 77 (05) : 247 - 255
  • [42] Five-year results of nonsurgical treatment to manage severe generalized aggressive periodontitis
    Hamad, Chaman
    Haller, Bernd
    Hoffmann, Thomas
    Lorenz, Katrin
    [J]. QUINTESSENCE INTERNATIONAL, 2019, 50 (02): : 104 - 113
  • [43] Results of hearing screenings in 14-to 15-year old adolescents
    Weichbold, V.
    Holzer, A.
    Newesely, G.
    Zorowka, P.
    Stephan, K.
    [J]. HNO, 2013, 61 (01) : 25 - 29
  • [44] Five-Year Visual Field Outcomes of the
    Montesano, Giovanni
    Ometto, Giovanni
    Ahmed, Iqbal Ike K.
    Ramulu, Pradeep Y.
    Chang, David F.
    Crabb, David P.
    Gazzard, Gus
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2023, 251 : 143 - 155
  • [45] Functional Results in Patients with Bone Anchored Hearing Aid
    Bitere, Oana
    Martu, Cristian
    Olariu, Raluca
    Cobzeanu, Bogdan
    Martu, Dan
    Cozma, Sebastian
    [J]. PROCEEDINGS OF NATIONAL ENT, HEAD AND NECK SURGERY CONFERENCE, 2018, : 75 - 81
  • [46] Hispanic/Latino Perspectives on Hearing Loss and Hearing Healthcare: Focus Group Results
    Arnold, Michelle L.
    Reyes, Cruz Arianna
    Lugo-Reyes, Natalia
    Sanchez, Victoria A.
    [J]. EAR AND HEARING, 2022, 43 (06) : 1620 - 1634
  • [47] Clinical evaluation of a fully implantable hearing device in six patients with mixed and sensorineural hearing loss: Our experience
    Kam, A. C. S.
    Sung, J. K. K.
    Yu, J. K. Y.
    Tong, M. C. F.
    [J]. CLINICAL OTOLARYNGOLOGY, 2012, 37 (03) : 240 - 244
  • [48] The application of implantable hearing aids using the Vibrant Soundbridge as an example
    Strenger, T.
    Stark, T.
    [J]. HNO, 2012, 60 (02) : 169 - 176
  • [49] Implantable electro-mechanical devices for sensorineural hearing loss
    Claes, J.
    Van de Heyning, P. H.
    [J]. B-ENT, 2007, : 51 - 56
  • [50] A Comprehensive Model of Human Ear for Analysis of Implantable Hearing Devices
    Zhang, Xiangming
    Gan, Rong Z.
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2011, 58 (10) : 3024 - 3027