Radiation Therapy in Patients with Implanted Cardiac Pacemakers and Implantable Cardioverter Defibrillators: A Prospective Survey in Japan

被引:39
作者
Soejima, Toshinori [1 ]
Yoden, Eisaku [2 ]
Nishimura, Yasumasa [3 ]
Ono, Seiji [4 ]
Yoshida, Akihiro [5 ]
Fukuda, Haruyuki [6 ]
Fukuhara, Noboru [7 ]
Sasaki, Ryohei [8 ]
Tsujino, Kayoko [1 ]
Norihisa, Yoshiki [9 ]
机构
[1] Hyogo Canc Ctr, Dept Radiat Oncol, Akashi, Hyogo 6738558, Japan
[2] Kawasaki Med Sch, Dept Radiat Oncol, Kurashiki, Okayama 7010192, Japan
[3] Kinki Univ, Dept Radiat Oncol, Fac Med, Osaka 5898511, Japan
[4] Kyushu Univ Hlth & Welf, Nobeoka 8828508, Japan
[5] Kobe Grad Univ, Sch Med, Div Cardiovasc & Resp Med, Chuo Ku, Kobe, Hyogo 6500017, Japan
[6] Osaka Saiseikai Nakatsu Hosp, Dept Radiat Oncol, Kita Ku, Osaka 5300012, Japan
[7] Sagamihara Kyodo Hosp, Dept Radiol, Midori Ku, Sagamihara, Kanagawa 2525188, Japan
[8] Kobe Grad Univ, Div Radiat Oncol, Sch Med, Chuo Ku, Kobe, Hyogo 6500017, Japan
[9] Kyoto Univ, Grad Sch Med, Dept Radiat Oncol & Image Appl Therapy, Sakyo Ku, Kyoto 6068507, Japan
关键词
Radiotherapy; Pacemaker; ICD; Malfunction; RADIOTHERAPY;
D O I
10.1269/jrr.10143
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Patients with implanted cardiac pacemakers (ICPs) or implantable cardioverter defibrillators (ICDs) are increasing in number, and the incidence of treating these patients with radiation therapy also is increasing. Thus, a prospective survey was conducted of patients with these devices receiving radiation therapy. A prospective survey of patients with ICPs or ICDs treated with radiation therapy was conducted on methods of radiation therapy, status of ICP/ICD, and management of patients before, during, and after radiation therapy. After completion of radiation therapy, study participants were registered via mail, fax, or e-mail. Sixty-two patients from 29 institutions were registered from September 2006 to December 2008. Sixty patients had an ICP and 2 had an ICD. The total dose was estimated before radiation therapy by dose-volume histogram in 26 patients (42%) and by measurement of actual doses in 9 (15%). In one patient, the maximum total dose was 2069 cGy; however, in the other patients, the ICP/ICD dose did not exceed 478 cGy. Function of ICPs and ICDs was checked before radiation therapy in 38 patients (61%), after radiation therapy in 32 (52%), and both before and after radiation therapy in 29 (47%). ICP malfunction occurred in a patient with prostate cancer treated by intensity-modulated radiation therapy to the prostate. Even when an ICP or ICD is not within the field of radiation, malfunction of the device may still occur. To minimize the risk to patients, precautions must be taken during the planning and administration of radiation therapy.
引用
收藏
页码:516 / 521
页数:6
相关论文
共 14 条
[1]  
[Anonymous], ASTRO NEWSL
[2]   Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure [J].
Bardy, GH ;
Lee, KL ;
Mark, DB ;
Poole, JE ;
Packer, DL ;
Boineau, R ;
Domanski, M ;
Troutman, C ;
Anderson, J ;
Johnson, G ;
McNulty, SE ;
Clapp-Channing, N ;
Davidson-Ray, LD ;
Fraulo, ES ;
Fishbein, DP ;
Luceri, RM ;
Ip, JH .
NEW ENGLAND JOURNAL OF MEDICINE, 2005, 352 (03) :225-237
[3]   IMPLANTED CARDIAC DEFIBRILLATOR CARE IN RADIATION ONCOLOGY PATIENT POPULATION [J].
Gelblum, Daphna Y. ;
Amols, Howard .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 73 (05) :1525-1531
[4]   Methodology for determining doses to in-field, out-of-field and partially in-field organs for late effects studies in photon radiotherapy [J].
Howell, Rebecca M. ;
Scarboro, Sarah B. ;
Taddei, Phillip J. ;
Krishnan, Sunil ;
Kry, Stephen F. ;
Newhauser, Wayne D. .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (23) :7009-7023
[5]  
Jaeger M, 1991, Schweiz Rundsch Med Prax, V80, P109
[6]   Radiotherapy in patients with cardiac pacemakers [J].
Last, A .
BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (841) :4-10
[7]   RUNAWAY ATRIOVENTRICULAR SEQUENTIAL PACEMAKER AFTER RADIATION-THERAPY [J].
LEE, RW ;
HUANG, SK ;
MECHLING, E ;
BAZGAN, I .
AMERICAN JOURNAL OF MEDICINE, 1986, 81 (05) :883-886
[8]   EFFECTS ON CARDIAC-PACEMAKERS OF IONIZING-RADIATION AND ELECTROMAGNETIC-INTERFERENCE FROM RADIOTHERAPY MACHINES [J].
MARBACH, JR ;
HUFFMAN, JK ;
HUDGINS, PT ;
MEOZMENDEZ, RT ;
ALMOND, PR .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1978, 4 (11-1) :1055-1058
[9]   MANAGEMENT OF RADIATION ONCOLOGY PATIENTS WITH IMPLANTED CARDIAC-PACEMAKERS - REPORT OF AAPM TASK GROUP NO-34 [J].
MARBACH, JR ;
SONTAG, MR ;
VANDYK, J ;
WOLBARST, AB .
MEDICAL PHYSICS, 1994, 21 (01) :85-90
[10]   PACEMAKER FAILURE RESULTING FROM RADIATION-DAMAGE [J].
QUERTERMOUS, T ;
MEGAHY, MS ;
DASGUPTA, DS ;
GRIEM, ML .
RADIOLOGY, 1983, 148 (01) :257-258