Correlation chromatograms from a triple-detector system

被引:2
|
作者
Singh, H [1 ]
Aue, WA [1 ]
机构
[1] DALHOUSIE UNIV,DEPT CHEM,HALIFAX,NS B3H 4J3,CANADA
基金
加拿大自然科学与工程研究理事会;
关键词
correlation chromatograms; detection; GC; gasoline; methylcyclopentadienylmanganese tricarbonyl;
D O I
10.1016/0021-9673(96)00018-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An electron-capture detector, two channels of a reactive-flow detector, and a flame-ionization detector mode were physically combined to investigate whether correlation (subtraction and conditional-access) chromatograms could be obtained from detectors that operated on entirely different principles and used separate, sequentially arranged monitoring chambers. The investigation was carried out with gasoline as a typical complex test sample. It showed that correlation chromatography, performed on different combinations of the three detectors, worked just as well as it had earlier on a solitary flame photometric detector. Relevant characteristics of correlational multi-detector systems are discussed in that context.
引用
收藏
页码:223 / 231
页数:9
相关论文
共 50 条
  • [1] An improved correlation based detector for a hand-held landmine detector
    Ho, KC
    Gader, PD
    DETECTION AND REMEDIATION TECHNOLOGIES FOR MINES AND MINELIKE TARGETS VI, PTS 1 AND 2, 2001, 4394 : 483 - 493
  • [2] Automatic peak detection algorithm based on continuous wavelet transform for complex chromatograms from multi-detector micro-scale gas chromatographs
    Zhao, Xiangyu
    Aridi, Ryan
    Hume, Jacob
    Subbiah, Swetha
    Wu, Xingqi
    Chung, Hyunwon
    Qin, Yutao
    Gianchandani, Yogesh B.
    JOURNAL OF CHROMATOGRAPHY A, 2024, 1714
  • [3] Gas chromatographic system equipped with a mass detector and a selective nitrogen-phosphorous detector operating simultaneously in the analysis of pesticide residues
    Morello, M
    Previale, L
    Quaglino, P
    JOURNAL OF CHROMATOGRAPHY A, 1996, 740 (02) : 263 - 271
  • [4] A Blind Time-Reversal Detector in the Presence of Channel Correlation
    Zheng, Zhong
    Wei, Lu
    Hamalainen, Jyri
    Tirkkonen, Olav
    IEEE SIGNAL PROCESSING LETTERS, 2013, 20 (05) : 459 - 462
  • [5] Quantitative evaluation of chromatograms from totally illuminated thin-layer chromatographic plates
    Vovk, I
    Prosek, M
    JOURNAL OF CHROMATOGRAPHY A, 1997, 768 (02) : 329 - 333
  • [6] Characterization of chlorinated compounds using a dual chlorine-selective pulsed discharge emission detector-helium-pulsed discharge photoionization detector system
    Sun, KF
    Wentworth, WE
    Stearns, SD
    JOURNAL OF CHROMATOGRAPHY A, 2000, 872 (1-2) : 179 - 189
  • [7] Ultrasonic fog detector for greenhouse with evaporative fog cooling system
    Mizutani, K
    Futamata, R
    Itoga, K
    Ishii, M
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2005, 44 (6B): : 4399 - 4402
  • [8] A radio detector system for ultra high energy cosmic showers
    Damazio, DO
    Takai, H
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 134 - 138
  • [9] A system consisted of flame ionization detector and sulfur chemiluminescence detector for interference free determination of total sulfur in natural gas
    Pan, Yi
    Li, Zhi-Ang
    Zhou, Xin
    Wang, Wei-Kang
    Wang, Xing
    Fang, Zheng
    Zheng, Cheng-Bin
    CHINESE CHEMICAL LETTERS, 2017, 28 (08) : 1670 - 1674
  • [10] Broad Learning System-Based Detector for OFDM With Index Modulation
    Du, Ruiyan
    Wang, Shiyi
    Liu, Fulai
    IEEE COMMUNICATIONS LETTERS, 2023, 27 (01) : 224 - 228