Female and male serum reference intervals for challenging sex and precursor steroids by liquid chromatography - tandem mass spectrometry

被引:30
作者
Mezzullo, Marco
Pelusi, Carla
Fazzini, Alessia
Repaci, Andrea
Di Dalmazi, Guido
Gambineri, Alessandra
Pagotto, Uberto
Fanelli, Flaminia
机构
[1] Univ Bologna, S Orsola Policlin, Dept Med & Surg Sci, Endocrinol Unit, Via Massarenti 9, I-40138 Bologna, Italy
[2] Univ Bologna, S Orsola Policlin, Dept Med & Surg Sci, Ctr Appl Biomed Res, Via Massarenti 9, I-40138 Bologna, Italy
关键词
estrogen; dihydrotestosterone; 17-hydroxypregnenolone; LC-MS/MS; immunoassays; reference intervals; LC-MS/MS; POSTMENOPAUSAL WOMEN; ESTRONE LEVELS; HUMAN PLASMA; ESTRADIOL; TESTOSTERONE; ASSAY; DIHYDROTESTOSTERONE; DERIVATIZATION; MEN;
D O I
10.1016/j.jsbmb.2019.105538
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Measuring some sex and precursor steroids is still challenging even by liquid chromatography - tandem mass spectrometry (LC-MS/MS), and few normal values are available. We developed a LC-MS/MS method for estradiol, estrone, dihydrotestosterone and 17-hydroxypregnenolone measurement, compared it with direct immunoassays, and generated sex, age, menopausal and menstrual status specific reference intervals. Liquid-liquid extraction was optimized on 300 mu L serum spiked with isotopic internal standards. A 2D-LC system allowed online purification and separation in 11 min run. Electrospray ionization was enhanced by ammonium fluoride. MS-detection was obtained by multiple reaction monitoring. Direct ECLIA for estradiol (n = 80) and RIA for estrone (n = 41) were compared with LC-MS/MS. Reference values were estimated in healthy, lean women in reproductive age (n = 118), menopausal women (n = 33) and men (n = 159). The assay showed satisfying imprecision, trueness, recovery and selectivity. Adequate functional sensitivity was achieved for measuring estrone (18.1 pmol/L) and 17-hydroxypregnenolone (117 pmol/L) in all subjects, and estradiol (35.9 pmol/L) and dihydrotestosterone (134 pmol/L) in women in reproductive age and men, but not in menopausal women. Compared with LC-MS/MS, immunoassays showed good agreement for estradiol but severe disagreement for estrone. Estrogens exhibited sex, menopausal and menstrual variations. Dihydrotestosterone and 17-hydroxypregnenolone depended on sex and menopause, the latter also declining with age in men. Strictly defined reference intervals in the adult female and male population were generated for challenging steroids such as estrogens, dihydrotestosterone and 17-hydroxypregnenolone by a novel LC-MS/MS method. Our achievement can be used to deepen the comprehension of several endocrine diseases.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Determination of testosterone in serum by liquid chromatography-tandem mass spectrometry
    Turpeinen, U.
    Linko, S.
    Itkonen, O.
    Hamalainen, E.
    [J]. SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2008, 68 (01) : 50 - 57
  • [32] Reference Intervals of Serum Metabolites and Lipids of a Healthy Chinese Population Determined by Liquid Chromatography-Mass Spectrometry
    Zhang, Yuqing
    Zhao, Jinhui
    Zhao, Hui
    Lu, Xin
    Jia, Xueni
    Zhao, Xinjie
    Xu, Guowang
    [J]. METABOLITES, 2025, 15 (02)
  • [33] Determination of aldosterone in serum by liquid chromatography-tandem mass spectrometry
    Turpeinen, Ursula
    Hamalainen, Esa
    Stenman, Ulf-Hakan
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 862 (1-2): : 113 - 118
  • [34] Determination of 17α-methyltestosterone in Bovine Serum Using Liquid Chromatography Tandem Mass Spectrometry
    Regal, Patricia
    Nebot, Carolina
    Vazquez, Beatriz I.
    Cepeda, Alberto
    Fente, Cristina A.
    [J]. JOURNAL OF FOOD AND DRUG ANALYSIS, 2010, 18 (01) : 51 - 57
  • [35] Serum hepcidin measurements in healthy dogs using liquid chromatography/tandem mass spectrometry
    Vizi, Zsuzsanna
    Lanyi, Katalin
    Bagi, Melinda
    Laczay, Peter
    Balogh, Nandor
    Sterczer, Agnes
    [J]. VETERINARY CLINICAL PATHOLOGY, 2020, 49 (02) : 292 - 298
  • [36] Input of liquid chromatography coupled with tandem mass spectroscopy technology for steroids assays
    Leban, M.
    [J]. MEDECINE NUCLEAIRE-IMAGERIE FONCTIONNELLE ET METABOLIQUE, 2013, 37 (01): : 8 - 13
  • [37] Analytical Performance Evaluation for Estradiol using Liquid Chromatography-Tandem Mass Spectrometry
    Won, Eun Jeong
    Yi, Ahram
    Ko, Young Jin
    [J]. CLINICAL BIOCHEMISTRY, 2023, 113 : 59 - 63
  • [38] Simultaneous determination of endogenous steroid hormones in human and animal plasma and serum by liquid or gas chromatography coupled to tandem mass spectrometry
    Abdel-Khalik, Jonas
    Bjorklund, Erland
    Hansen, Martin
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 928 : 58 - 77
  • [39] Comparative limitations and benefits of liquid chromatography - mass spectrometry techniques for analysis of sex steroids in tears
    Gibson, Emma J.
    Bucknall, Martin P.
    Golebiowski, Blanka
    Stapleton, Fiona
    [J]. EXPERIMENTAL EYE RESEARCH, 2019, 179 : 168 - 178
  • [40] Comparison of liquid chromatography-microchip/mass spectrometry to conventional liquid chromatography-mass spectrometry for the analysis of steroids
    Ahonen, Linda
    Keski-Rahkonen, Pekka
    Saarelainen, Taija
    Paviala, Jenni
    Ketola, Raimo A.
    Auriola, Seppo
    Poutanen, Matti
    Kostiainen, Risto
    [J]. ANALYTICA CHIMICA ACTA, 2012, 721 : 115 - 121