Simplified automatic fault detection in wind turbine induction generators

被引:8
作者
Brigham, Katharine [1 ,2 ]
Zappala, Donatella [1 ]
Crabtree, Christopher J. [1 ]
Donaghy-Spargo, Christopher [1 ]
机构
[1] Univ Durham, Dept Engn, Durham, England
[2] South Rd, Durham DH1 3LE, England
基金
英国工程与自然科学研究理事会;
关键词
automated detection; condition monitoring; fault detection; rotor electrical asymmetry; speed invariance; SIGNATURE ANALYSIS; ROTOR; DIAGNOSIS; MACHINES; RELIABILITY;
D O I
10.1002/we.2478
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper presents a simplified automated fault detection scheme for wind turbine induction generators with rotor electrical asymmetries. Fault indicators developed in previous works have made use of the presence of significant spectral peaks in the upper sidebands of the supply frequency harmonics; however, the specific location of these peaks may shift depending on the wind turbine speed. As wind turbines tend to operate under variable speed conditions, it may be difficult to predict where these fault-related peaks will occur. To accommodate for variable speeds and resulting shifting frequency peak locations, previous works have introduced methods to identify or track the relevant frequencies, which necessitates an additional set of processing algorithms to locate these fault-related peaks prior to any fault analysis. In this work, a simplified method is proposed to instead bypass the issue of variable speed (and shifting frequency peaks) by introducing a set of bandpass filters that encompass the ranges in which the peaks are expected to occur. These filters are designed to capture the fault-related spectral information to train a classifier for automatic fault detection, regardless of the specific location of the peaks. Initial experimental results show that this approach is robust against variable speeds and further shows good generalizability in being able to detect faults at speeds and conditions that were not presented during training. After training and tuning the proposed fault detection system, the system was tested on "unseen" data and yielded a high classification accuracy of 97.4%, demonstrating the efficacy of the proposed approach.
引用
收藏
页码:1135 / 1144
页数:10
相关论文
共 34 条
  • [1] [Anonymous], 2014, SURVEY COMMERCIALLY
  • [2] [Anonymous], 2011, WIND ENERGY HDB
  • [3] Wind turbine reliability: A comprehensive review towards effective condition monitoring development
    Artigao, Estefania
    Martin-Martinez, Sergio
    Honrubia-Escribano, Andres
    Gomez-Lazaro, Emilio
    [J]. APPLIED ENERGY, 2018, 228 : 1569 - 1583
  • [4] A review of induction motors signature analysis as a medium for faults detection
    Benbouzid, ME
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2000, 47 (05) : 984 - 993
  • [5] Bishop Christopher M., 2006, BISHOP PATTERN RECOG, DOI DOI 10.1117/1.2819119
  • [6] Failure rate, repair time and unscheduled O&M cost analysis of offshore wind turbines
    Carroll, James
    McDonald, Alasdair
    McMillan, David
    [J]. WIND ENERGY, 2016, 19 (06) : 1107 - 1119
  • [7] Reliability Comparison of Wind Turbines With DFIG and PMG Drive Trains
    Carroll, James
    McDonald, Alasdair
    McMillan, David
    [J]. IEEE TRANSACTIONS ON ENERGY CONVERSION, 2015, 30 (02) : 663 - 670
  • [8] Wind energy: UK experiences and offshore operational challenges
    Crabtree, Christopher J.
    Zappala, Donatella
    Hogg, Simon I.
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2015, 229 (07) : 727 - 746
  • [9] Crabtree CJ, 2011, THESIS
  • [10] Condition monitoring of wind turbine induction generators with rotor electrical asymmetry
    Djurovic, S.
    Crabtree, C. J.
    Tavner, P. J.
    Smith, A. C.
    [J]. IET RENEWABLE POWER GENERATION, 2012, 6 (04) : 207 - 216