Helical tomotherapy and intensity modulated proton therapy in the treatment of early stage prostate cancer: A treatment planning comparison

被引:28
作者
Schwarz, Marco [1 ]
Pierelli, Alessio [2 ]
Fiorino, Claudio [2 ]
Fellin, Francesco [1 ]
Cattaneo, Giovanni Mauro [2 ]
Cozzarini, Cesare [2 ]
Di Muzio, Nadia [2 ]
Calandrino, Riccardo [2 ]
Widesott, Lamberto [1 ]
机构
[1] Agenzia Prov Protonterapia, I-38122 Trento, Italy
[2] Ist Sci San Raffaele, Milan, Italy
关键词
IMPT; Tomotherapy; Prostate; Planning comparison; DOSE-ESCALATION TRIAL; X-RAY THERAPY; CONFORMAL RADIOTHERAPY; IMAGE-GUIDANCE; VOLUME; IMRT; OPTIMIZATION; MULTICENTER; ISSUES; TUMORS;
D O I
10.1016/j.radonc.2010.10.027
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To compare helical tomotherapy (HT) and intensity modulated proton therapy (IMPT) on early stage prostate cancer treatments delivered with simultaneous integrated boost (SIB) in moderate hypofractionation. Material/methods: Eight patients treated with HT were replanned with two-field IMPT (2fIMPT) and five-field IMPT (5fIMPT), using a small pencil beam size (3 mm sigma). The prescribed dose was 74.3 Gy in 28 fractions on PTV1 (prostate) and PTV2 (proximal seminal vesicles), 65.5 Gy on PTV3 (distal seminal vesicles) and on the overlap between rectum and PTVs. Results: IMPT and HT achieved similar target coverage and dose homogeneity, with 5fIMPT providing the best results. The conformity indexes of IMPT were significantly lower for PTV1+2 and PTV3. Above 65 Gy, HT and IMPT were equivalent in the rectum, while IMPT spared the bladder and the penile bulb from 0 to 70 Gy. From 0 up to 60 Gy, IMPT dosimetric values were (much) lower for all OARs except the femur heads, where HT was better than 2fIMPT in the 25-35 Gy dose range. OARs mean doses were typically reduced by 30-50% by IMPT. NTCPs for the rectum were within 1% between the two techniques, except when the endpoint was stool frequency, where IMPT showed a small (though statistically significant) benefit. Conclusions: HT and IMPT produce similar dose distributions in the target volume. The current knowledge on dose-effect relations does not allow to quantify the clinical impact of the large sparing of IMPT at medium-to-low doses. (C) 2010 Elsevier Ireland Ltd. All rights reserved. Radiotherapy and Oncology 98 (2011) 74-80
引用
收藏
页码:74 / 80
页数:7
相关论文
共 50 条
  • [31] Intensity-modulated proton therapy (IMPT) versus intensity-modulated radiation therapy (IMRT) for the treatment of head and neck cancer: A dosimetric comparison
    Nguyen, My-Lien
    Cantrell, J. Nathan
    Ahmad, Salahuddin
    Henson, Christina
    MEDICAL DOSIMETRY, 2021, 46 (03) : 259 - 263
  • [32] Comparison of intensity-modulated radiation therapy (IMRT), 3D conformal proton therapy and intensity-modulated proton therapy (IMPT) for the treatment of metastatic brain cancer
    Sullivan, Matthew
    Jin, Hosang
    Ahmad, Salahuddin
    MEDICAL DOSIMETRY, 2023, 48 (02) : 73 - 76
  • [33] Comparison of different treatment planning approaches for intensity-modulated proton therapy with simultaneous integrated boost for pancreatic cancer
    Stefanowicz, Sarah
    Stuetzer, Kristin
    Zschaeck, Sebastian
    Jakobi, Annika
    Troost, Esther G. C.
    RADIATION ONCOLOGY, 2018, 13 : 228
  • [34] Rapid Arc, helical tomotherapy, sliding window intensity modulated radiotherapy and three dimensional conformal radiation for localized prostate cancer: A dosimetric comparison
    Kinhikar, Rajesh A.
    Pawar, Amol B.
    Mahantshetty, Umesh
    Murthy, Vedang
    Dheshpande, Deepak D.
    Shrivastava, Shyam K.
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2014, 10 (03) : 575 - 582
  • [35] A Prospective Comparison of the Effects of Interfractional Variations on Proton Therapy and Intensity Modulated Radiation Therapy for Prostate Cancer
    Moteabbed, Maryam
    Trofimov, Alexei
    Sharp, Gregory C.
    Wang, Yi
    Zietman, Anthony L.
    Efstathiou, Jason A.
    Lu, Hsiao-Ming
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 95 (01): : 444 - 453
  • [36] Skull Base Meningioma - Comparison of Intensity-modulated Radiotherapy Planning Techniques using the Moduleaf Micro-multileaf Collimator and Helical Tomotherapy
    Estall, V.
    Fairfoul, J.
    Jena, R.
    Jefferies, S. J.
    Burton, K. E.
    Burnet, N. G.
    CLINICAL ONCOLOGY, 2010, 22 (03) : 179 - 184
  • [37] Treatment of prostate cancer with intensity modulated radiation therapy (IMRT)
    Novaes, P. E. R. S.
    Motta, R. T.
    Lundgren, M. S. F. S.
    REVISTA DA ASSOCIACAO MEDICA BRASILEIRA, 2015, 61 (01): : 8 - 16
  • [38] Dosimetric Comparison of Helical Tomotherapy and Intensity-Modulated Proton Therapy in Hippocampus- and Scalp-Sparing Whole Brain Radiotherapy
    Takaoka, Taiki
    Tomita, Natsuo
    Mizuno, Tomoki
    Hashimoto, Shingo
    Tsuchiya, Takahiro
    Tomida, Masashi
    Yanagi, Takeshi
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2021, 20
  • [39] SMARTARC-BASED VOLUMETRIC MODULATED ARC THERAPY FOR OROPHARYNGEAL CANCER: A DOSIMETRIC COMPARISON WITH BOTH INTENSITY-MODULATED RADIATION THERAPY AND HELICAL TOMOTHERAPY
    Clemente, Stefania
    Wu, BinBin
    Sanguineti, Giuseppe
    Fusco, Vincenzo
    Ricchetti, Francesco
    Wong, John
    McNutt, Todd
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 80 (04): : 1248 - 1255
  • [40] Comparison between two treatment planning systems for volumetric modulated arc therapy optimization for prostate cancer
    Lafond, Caroline
    Gassa, Frederic
    Odin, Christophe
    Drean, Gael
    Even, Justine
    De Crevoisier, Renaud
    Pommier, Pascal
    Manens, Jean-Pierre
    Biston, Marie-Claude
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2014, 30 (01): : 2 - 9