Experimental study of the effect of hydrodynamic coupling of micro-cantilever array on the dynamic response of micro-cantilever

被引:2
|
作者
Lee, Jiunn-Horng [2 ,3 ]
Lau, Yung-Dong [1 ]
Yao, Chih-Min [3 ]
Fang, Weileun [1 ,2 ]
机构
[1] Natl Tsing Hua Univ, Dept Power Mech Engn, Hsinchu, Taiwan
[2] Natl Tsing Hua Univ, Inst NanoEngn & MicroSyst, Hsinchu, Taiwan
[3] Natl Ctr High Performance Comp, Natl Appl Res Labs, Hsinchu, Taiwan
关键词
Micro-cantilever array; Quality factor; Air damping; Hydrodynamic force; QUALITY FACTOR; MICROCANTILEVERS; RESONATORS; BIOSENSORS; SENSORS; FORCE; MEMS;
D O I
10.1016/j.sna.2009.12.024
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This study experimentally investigates the effect of hydrodynamic coupling of a micro-cantilever array on the dynamic response of a micro-cantilever. The micro-cantilever array consists of three harmonically driven micro-cantilevers dynamically coupled through air flow. The right cantilever and left cantilever (auxiliary-cantilevers) adjacent to the middle cantilever (operating-cantilever) are exploited to generate hydrodynamic force to change the air damping of operating-cantilever. Thus, the quality factor of operating-cantilever can be controlled by changing the phase and magnitude of excitation force on auxiliary-cantilevers, and varying the gap between auxiliary-cantilevers and operating-cantilever. In the experiment, magnetic actuated micro-cantilever arrays were fabricated and characterized. Measurements show the variation of quality factor of operating-cantilever is from -39% to +27%. (c) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:79 / 85
页数:7
相关论文
共 50 条
  • [31] Gas Flow Sensing with a Piezoresistive Micro-Cantilever
    Wang, Yu-Hsiang
    Lee, Chia-Yen
    Ma, Rong-Hua
    Fu, Lung-Ming
    2006 IEEE SENSORS, VOLS 1-3, 2006, : 1448 - +
  • [32] A piezoresistive micro-cantilever for thermal infrared detector
    School of Electrical Engineering, Xi'an Jiaotong University, Xi'an 710049, China
    不详
    Chin. Opt. Lett., 2006, 3 (128-130):
  • [33] Modelling and analysis of autonomous micro-cantilever oscillations
    Basso, M.
    Paoletti, P.
    Tiribilli, B.
    Vassalli, M.
    NANOTECHNOLOGY, 2008, 19 (47)
  • [34] Testing and Characterization of a MEMS Micro-Cantilever System
    Kafumbe, Said
    Harris, Alun
    Burdess, Jim
    2016 IEEE 59TH INTERNATIONAL MIDWEST SYMPOSIUM ON CIRCUITS AND SYSTEMS (MWSCAS), 2016, : 529 - 532
  • [35] Simulation fabrication and characterization of micro-cantilever array based ozone sensor
    Amiri, Iraj S.
    Addanki, Satish
    RESULTS IN PHYSICS, 2018, 10 : 923 - 933
  • [36] Polymeric micro-cantilever array for auditory front-end processing
    Xu, T
    Bachman, M
    Zeng, FG
    Li, GP
    SENSORS AND ACTUATORS A-PHYSICAL, 2004, 114 (2-3) : 176 - 182
  • [37] Design and fabrication of electrostatic micro-cantilever array as audible frequency generator
    Arya, Sandeep
    Khan, Saleem
    Lehana, Parveen
    JOURNAL OF ELECTROSTATICS, 2015, 76 : 145 - 151
  • [38] Dimension effect on mechanical behavior of silicon micro-cantilever beams
    Liu, Hsien-Kuang
    Pan, C. H.
    Liu, Pang-Ping
    MEASUREMENT, 2008, 41 (08) : 885 - 895
  • [39] Study on Reliability of Slanted Micro-Cantilever under Shock Stress
    Tao, Junyong
    Liu, Bin
    Li, Xiaotao
    Zhang, Yun-an
    SENSORS, MEASUREMENT AND INTELLIGENT MATERIALS, PTS 1-4, 2013, 303-306 : 1725 - 1731
  • [40] Dynamic Characteristics Measurement of Silicon Micro-cantilever in Low Temperature Environment
    She, D. S.
    Wang, X. D.
    Zhang, X. W.
    Wang, L. D.
    MEMS/NEMS NANO TECHNOLOGY, 2011, 483 : 18 - 22