Detection and localization of partial discharge in high voltage power cable joints

被引:2
|
作者
Kheirmand, A [1 ]
Leijon, M [1 ]
Tornkvist, C [1 ]
机构
[1] ABB Corp Res, Dept H, S-72178 Vasteras, Sweden
关键词
D O I
10.1109/ICSD.1998.709246
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Laboratory performance test of the high voltage power cable joints at lower voltages is not crucial, nor has the continuous monitoring of partial discharge (PD) been considered necessary. However for KV power cable joints at higher voltages, such as 420_kV, the reliable PD detection during performance test as well as the on-line continuous PD monitoring have been considered desirable to an increasing extent[1, 2]. Accordingly, a system was developed to facilitate such tasks. The system is based on decoupling of PD by means of the inductive sensors, signal treatment and investigation according to a technique called INTECH, Inductive Measurement Technique. The laboratory system sensitivity is about 5_pC when the cable is not loaded with any power current and about 30_pC when the cable load is about 2000_A. The first prototype system was tested at the field on a 420_kV cable joint. This paper describes the system and presents some of the field test results.
引用
收藏
页码:145 / 148
页数:4
相关论文
共 50 条
  • [41] A fiber optic sensor for the detection of Partial Discharge within the High Voltage power transformer
    Sarkar, B.
    Koley, C.
    Roy, N. K.
    Kumbhakar, P.
    FOUNDATIONS AND FRONTIERS IN COMPUTER, COMMUNICATION AND ELECTRICAL ENGINEERING, 2016, : 177 - 181
  • [42] Study on partial discharge detection of 10kV power cable
    Weixia, Z. (zhangwx_love@126.com), 1795, Universitas Ahmad Dahlan (10):
  • [43] Partial Discharge Detection and Localization inside the Winding of Power Transformer
    Rotby, Sally N.
    El-Hag, Ayman H.
    Salama, M. M. A.
    Bartnikas, R.
    2012 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2012, : 84 - 87
  • [44] CONTROLLING DELETERIOUS EFFECTS OF PARTIAL DISCHARGE ON HIGH-VOLTAGE CABLE COUPLERS IN MINE POWER-SYSTEMS
    BISE, CJ
    KADYK, RC
    MINING ENGINEERING, 1984, 36 (03) : 265 - 270
  • [45] Electromagnetic finite differences time domain (FDTD) modeling of partial discharge coupling applied to high voltage cables and cable joints
    Pommerenke, D
    Jobava, R
    Heinrich, R
    EIGHTH INTERNATIONAL CONFERENCE ON DIELECTRIC MATERIALS, MEASUREMENTS AND APPLICATIONS, 2000, (473): : 497 - 502
  • [46] Noise reduction of partial discharge signal of high voltage cable based on VMD
    Ma X.
    Zhang D.
    International Journal of Performability Engineering, 2020, 16 (08) : 1193 - 1202
  • [47] Comparing tests of partial discharge on XLPE power cable at 0.1 Hz voltage and 50 Hz voltage
    Luo, Jun-Hua
    Fu, Li-Wei
    Tao, Shi-Li
    Li, Wen-Jie
    Gaodianya Jishu/High Voltage Engineering, 2010, 36 (08): : 2000 - 2004
  • [48] Partial Discharge Characteristics and Mechanism of Medium Voltage Power Cable Defects under Different Voltage Stresses
    Wang, Li
    Chen, Junbai
    Li, Hongjie
    Jin, Lei
    Zhao, Kun
    IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2023, 18 (10) : 1598 - 1606
  • [49] High Frequency Partial Discharge Measurement of Straight Power Cable Joint
    Chang, Wen-zhi
    Gong, Yan-peng
    Bi, Jian-gang
    Ma, Guo-ming
    Zhuang, Ying-chao
    2017 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2017, : 229 - 232
  • [50] Real On-Site Partial Discharge Measurement Technique in Medium Voltage Power Cable
    Abdullah, A. Z.
    Rohani, M. N. K. H.
    Isa, M.
    Hamid, H.
    Arshad, S. N. M.
    Othman, M.
    2018 IEEE 7TH INTERNATIONAL CONFERENCE ON POWER AND ENERGY (PECON), 2018, : 405 - 408