Detection and localization of partial discharge in high voltage power cable joints

被引:2
|
作者
Kheirmand, A [1 ]
Leijon, M [1 ]
Tornkvist, C [1 ]
机构
[1] ABB Corp Res, Dept H, S-72178 Vasteras, Sweden
关键词
D O I
10.1109/ICSD.1998.709246
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Laboratory performance test of the high voltage power cable joints at lower voltages is not crucial, nor has the continuous monitoring of partial discharge (PD) been considered necessary. However for KV power cable joints at higher voltages, such as 420_kV, the reliable PD detection during performance test as well as the on-line continuous PD monitoring have been considered desirable to an increasing extent[1, 2]. Accordingly, a system was developed to facilitate such tasks. The system is based on decoupling of PD by means of the inductive sensors, signal treatment and investigation according to a technique called INTECH, Inductive Measurement Technique. The laboratory system sensitivity is about 5_pC when the cable is not loaded with any power current and about 30_pC when the cable load is about 2000_A. The first prototype system was tested at the field on a 420_kV cable joint. This paper describes the system and presents some of the field test results.
引用
收藏
页码:145 / 148
页数:4
相关论文
共 50 条
  • [31] New partial discharge detection method for live UHV/EHV cable joints
    Fukunaga, K.
    Tan, M.
    Takehana, H.
    IEEE transactions on electrical insulation, 1992, 27 (02): : 669 - 674
  • [33] Partial Discharge Detection and Localization in Power Transformer Windings
    Abdul-Malek, Zulkurnain
    Aziz, Mohammed Abd Ali
    Aziz, Ali Saleh
    Mechanical and Materials Engineering, 2014, 554 : 578 - 582
  • [34] Comparison of on-line partial discharge detection methods for XLPE cable joints
    Williams, GM
    Lewin, PL
    Davies, AE
    Sutton, SJ
    Swingler, SG
    QRM 2002: PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON QUALITY, RELIABILITY, AND MAINTENANCE, 2002, : 319 - 322
  • [35] A sensitive method for on-site partial discharge detection on XLPE cable joints
    Schichler, U
    PROCEEDINGS OF THE 5TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1 AND 2, 1997, : 1099 - 1102
  • [36] Investigation on Partial Discharge Activity inside the Cable Accessories due to Improper Installation of Power Cable Joints
    Batalovic, Mirza
    Matoruga, Halid
    Berberovic, Sead
    Matoruga, Mirza
    PROCEEDINGS OF 18TH INTERNATIONAL CONFERENCE ON SMART TECHNOLOGIES (IEEE EUROCON 2019), 2019,
  • [37] Development of Partial Discharge Detection Device for PD Detection on Medium Voltage XLPE Cable
    Radzi, M. I. F. Mohamad
    Ahmad, M. R.
    Ali, N. H. Nik
    Ariffin, A. Mohd
    2020 8TH INTERNATIONAL CONFERENCE ON INTELLIGENT AND ADVANCED SYSTEMS (ICIAS), 2021,
  • [38] Partial discharge localization method of power cable using high-precision synchronization by atomic clocks
    Motoyama, Mamoru
    Ohtsuka, Shinya
    Hikita, Masayuki
    Suzuki, Hiroshi
    Abe, Kazutoshi
    PROCEEDINGS OF 2008 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS, 2007, : 1212 - +
  • [39] Development of a partial discharge detection algorithm and verification test for extra-high-voltage cable system
    Choi, Won
    Kim, Jeong-Tae
    Seo, In-Jin
    Hwang, Jae-Sang
    Koo, Ja-Yoon
    IET SCIENCE MEASUREMENT & TECHNOLOGY, 2016, 10 (02) : 111 - 119
  • [40] Numerical Sensor Design for Partial Discharge Detection on Power Cable Joint
    Ma, Guo-Ming
    Li, Cheng-Rong
    Chen, Xue-Wei
    Jiang, Jun
    Ge, Zhen-Dong
    Chang, Wen-Zhi
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2015, 22 (04) : 2311 - 2319