Laboratory performance test of the high voltage power cable joints at lower voltages is not crucial, nor has the continuous monitoring of partial discharge (PD) been considered necessary. However for KV power cable joints at higher voltages, such as 420_kV, the reliable PD detection during performance test as well as the on-line continuous PD monitoring have been considered desirable to an increasing extent[1, 2]. Accordingly, a system was developed to facilitate such tasks. The system is based on decoupling of PD by means of the inductive sensors, signal treatment and investigation according to a technique called INTECH, Inductive Measurement Technique. The laboratory system sensitivity is about 5_pC when the cable is not loaded with any power current and about 30_pC when the cable load is about 2000_A. The first prototype system was tested at the field on a 420_kV cable joint. This paper describes the system and presents some of the field test results.
引用
收藏
页码:145 / 148
页数:4
相关论文
共 50 条
  • [21] Analysis of Partial Discharge in Underground Cable Joints
    Rajalakshmi, B.
    Kalaivani, L.
    2015 INTERNATIONAL CONFERENCE ON INNOVATIONS IN INFORMATION, EMBEDDED AND COMMUNICATION SYSTEMS (ICIIECS), 2015,
  • [22] Detection of partial discharge in the high voltage apparatus
    Zheng, DC
    Zhang, CX
    Chen, CT
    Yu, CS
    Yang, JX
    PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3, 2003, : 323 - 326
  • [23] A partial discharge detection and localization system for high voltage cable based on long-tailed Sagnac interferometric fiber optic sensor
    Song, Zhe
    Guo, Mengjuan
    Wang, Qi
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2017, 59 (09) : 2132 - 2136
  • [24] Partial discharge characteristics of 10 kV XLPE cable joints under oscillating voltage
    State Key Laboratory of Power Transmission Equipment & System Security and New Technology, Chongqing University, Chongqing
    400030, China
    不详
    510410, China
    Gaodianya Jishu, 4 (1068-1074):
  • [25] Partial discharge detection in XLPE power cable with CT sensor
    Luo, JH
    Feng, J
    Yuan, J
    Ma, CJ
    Qiu, YC
    ICSD '01: PROCEEDINGS OF THE 2001 IEEE 7TH INTERNATIONAL CONFERENCE ON SOLID DIELECTRICS, 2001, : 400 - 403
  • [26] Classification of Partial Discharge Detection Technique in High Voltage Power Component: A Review
    Rohani, M. N. K. H.
    Zaidi, A. A. H.
    Sakanovic, A.
    Wooi, C. L.
    Rosmi, A. S.
    Isa, M.
    Ismail, B.
    INTERNATIONAL JOURNAL OF INTEGRATED ENGINEERING, 2019, 11 (04): : 237 - 243
  • [27] A Review of Partial Discharge Detection, Diagnosis Techniques in High Voltage Power Cables
    Refaat, Shady S.
    Shams, Mohammed A.
    PROCEEDINGS 2018 IEEE 12TH INTERNATIONAL CONFERENCE ON COMPATIBILITY, POWER ELECTRONICS AND POWER ENGINEERING (CPE-POWERENG 2018), 2018,
  • [28] Partial Discharge Detection and Localization along Medium Voltage Cables
    Andrade, M. A.
    Calamera, A.
    Candela, R.
    De Rai, L.
    Imburgia, A.
    Sanseverino, E. Riva
    Romano, P.
    Troia, I.
    Viola, F.
    2017 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENON (CEIDP), 2017, : 389 - 392
  • [29] Comparison of on-line partial discharge detection methods for HV cable joints
    Tian, Y
    Lewin, PL
    Davies, AE
    Swingler, SG
    Sutton, SJ
    Hathaway, GM
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2002, 9 (04) : 604 - 615
  • [30] NEW PARTIAL DISCHARGE DETECTION METHOD FOR LIVE UHV EHV CABLE JOINTS
    FUKUNAGA, K
    TAN, M
    TAKEHANA, H
    IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1992, 27 (03): : 669 - 674