Dose imaging detectors for radiotherapy based on gas electron multipliers

被引:9
作者
Klyachko, A. V. [1 ]
Friesel, D. L. [2 ]
Kline, C. [2 ]
Liechty, J. [2 ]
Nichiporov, D. F. [1 ]
Solberg, K. A. [1 ]
机构
[1] Indiana Univ Cyclotron Operat, Bloomington, IN USA
[2] PartTec Ltd, Bloomington, IN USA
关键词
GEM detector; Hadron therapy; Dose imaging; PROTON-BEAM; GEM; DOSIMETRY;
D O I
10.1016/j.nima.2010.07.019
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
New techniques in charged particle therapy and widespread use of modern dynamic beam delivery systems demand new beam monitoring devices as well as accurate two-dimensional dosimetry systems to verify the delivered dose distribution. We are developing dose imaging detectors based on gas electron multipliers (GEM) with the goal of improving dose measurement linearity, position and timing resolution, and to ultimately allow pre-treatment verification of dose distributions and dose delivery monitoring employing scanning beam technology. A prototype 10 X 10 cm(2) double-GEM detector has been tested in the 205 MeV proton beam using electronic and optical readout modes. Preliminary results with electronic cross-strip readout demonstrate fast response and single-pixel (4 mm) position resolution. In optical readout mode, the line spread function of the detector was found to have sigma = 0.7 mm. In both readout modes, the detector response was linear up to dose rates of 50 Gy/min, with adequate representation of the Bragg peak in depth-dose profile measurements. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:434 / 439
页数:6
相关论文
共 50 条
[21]   Visualization of dose distribution in intraoperative electron beam radiotherapy based on ultrasound images [J].
Winiecki, Janusz ;
Orzechowska, Agnieszka ;
Maleszka, Sebastian ;
Biedka, Marta ;
Wisniewski, Tomasz ;
Nowakowski, Slawomir ;
Makarewicz, Roman .
JOURNAL OF BUON, 2019, 24 (06) :2570-2576
[22]   Study of polymer gel for dose imaging in radiotherapy [J].
Vanossi, E. ;
Carrara, M. ;
Gambarini, G. ;
Mariani, M. ;
Valente, M. .
RADIATION MEASUREMENTS, 2008, 43 (2-6) :442-445
[23]   Development of digital imaging device based on the gas electron multiplier [J].
Park, Seongtae ;
Hahn, Chang Hie ;
Ha, Youngja ;
Ahn, Bongjae .
RADIATION MEASUREMENTS, 2007, 42 (10) :1661-1665
[24]   Dose imaging in radiotherapy with an Ar-CF4 filled scintillating GEM [J].
Fetal, S ;
van Eijk, CWE ;
Fraga, F ;
de Haas, J ;
Kreuger, R ;
van Vuure, TL ;
Schippers, JM .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 513 (1-2) :42-46
[25]   Polymer gels for in-phantom dose imaging in radiotherapy [J].
Vanossi, E. ;
Gambarini, G. ;
Carrara, M. ;
Mariani, M. .
APPLIED RADIATION AND ISOTOPES, 2010, 68 (4-5) :772-775
[26]   Development of a UV/X-ray imaging device based on large area gas photo-multipliers [J].
Sekiya, Hiroyuki .
PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON TECHNOLOGY AND INSTRUMENTATION IN PARTICLE PHYSICS (TIPP 2011), 2012, 37 :691-696
[27]   Measurement and effects of MOSKIN detectors on skin dose during high energy radiotherapy treatment [J].
Alnawaf, Hani ;
Butson, Martin ;
Yu, Peter K. N. .
AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2012, 35 (03) :321-328
[28]   Measurement and effects of MOSKIN detectors on skin dose during high energy radiotherapy treatment [J].
Hani Alnawaf ;
Martin Butson ;
Peter K. N. Yu .
Australasian Physical & Engineering Sciences in Medicine, 2012, 35 :321-328
[29]   Studying the potential of point detectors in time-resolved dose verification of dynamic radiotherapy [J].
Beierholm, A. R. ;
Behrens, C. F. ;
Andersen, C. E. .
RADIATION MEASUREMENTS, 2015, 82 :129-137
[30]   Plastic scintillator-based dosimeters for ultra-high dose rate (UHDR) electron radiotherapy [J].
Ciarrocchi, E. ;
Ravera, E. ;
Cavalieri, A. ;
Celentano, M. ;
Del Sarto, D. ;
Di Martino, F. ;
Linsalata, S. ;
Massa, M. ;
Masturzo, L. ;
Moggi, A. ;
Morrocchi, M. ;
Pensavalle, J. H. ;
Bisogni, M. G. .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2024, 121