Raw data normalization for a multi source inverse geometry CT system

被引:10
作者
Baek, Jongduk [1 ,2 ]
De Man, Bruno [3 ]
Harrison, Daniel [3 ]
Pelc, Norbert J. [4 ,5 ]
机构
[1] Yonsei Univ, Sch Integrated Technol, Inchon, South Korea
[2] Yonsei Univ, Yonsei Inst Convergence Technol, Inchon, South Korea
[3] GE Global Res, Niskayuna, NY USA
[4] Stanford Univ, Dept Bioengn, Stanford, CA 94305 USA
[5] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
关键词
TOMOGRAPHY;
D O I
10.1364/OE.23.007514
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A multi-source inverse-geometry CT (MS-IGCT) system consists of a small 2D detector array and multiple x-ray sources. During data acquisition, each source is activated sequentially, and may have random source intensity fluctuations relative to their respective nominal intensity. While a conventional 3rd generation CT system uses a reference channel to monitor the source intensity fluctuation, the MS-IGCT system source illuminates a small portion of the entire field-of-view (FOV). Therefore, it is difficult for all sources to illuminate the reference channel and the projection data computed by standard normalization using flat field data of each source contains error and can cause significant artifacts. In this work, we present a raw data normalization algorithm to reduce the image artifacts caused by source intensity fluctuation. The proposed method was tested using computer simulations with a uniform water phantom and a Shepp-Logan phantom, and experimental data of an ice-filled PMMA phantom and a rabbit. The effect on image resolution and robustness of the noise were tested using MTF and standard deviation of the reconstructed noise image. With the intensity fluctuation and no correction, reconstructed images from simulation and experimental data show high frequency artifacts and ring artifacts which are removed effectively using the proposed method. It is also observed that the proposed method does not degrade the image resolution and is very robust to the presence of noise. (C) 2015 Optical Society of America
引用
收藏
页码:7514 / 7526
页数:13
相关论文
共 17 条
[1]  
[Anonymous], P SPIE
[2]  
[Anonymous], P SPIE
[3]  
[Anonymous], HIGH POWER DISTRIBUT
[4]   A multi-source inverse-geometry CT system: initial results with an 8 spot x-ray source array [J].
Baek, Jongduk ;
De Man, Bruno ;
Uribe, Jorge ;
Longtin, Randy ;
Harrison, Daniel ;
Reynolds, Joseph ;
Neculaes, Bogdan ;
Frutschy, Kristopher ;
Inzinna, Louis ;
Caiafa, Antonio ;
Senzig, Robert ;
Pelc, Norbert J. .
PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (05) :1189-1202
[5]   Data normalization method for a multi-source inverse geometry CT system [J].
Baek, Jongduk ;
Pelc, Norbert J. .
MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
[6]   OPTICAL TOMOGRAPHY - EXPERIMENTAL-VERIFICATION OF NOISE THEORY [J].
BENNETT, K ;
BYER, RL .
OPTICS LETTERS, 1984, 9 (07) :270-272
[7]   FAN-BEAM-TOMOGRAPHY NOISE THEORY [J].
BENNETT, KE ;
BYER, RL .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1986, 3 (05) :624-633
[8]   EXPERIMENTAL OPTICAL FAN BEAM TOMOGRAPHY [J].
BENNETT, KE ;
FARIS, GW ;
BYER, RL .
APPLIED OPTICS, 1984, 23 (16) :2678-2685
[9]  
De Man B, 2007, IEEE NUCL SCI CONF R, P2715
[10]   Multi-source inverse-geometry CT: from system concept to research prototype [J].
De Man, Bruno ;
Caiafa, Antonio ;
Cao, Yang ;
Frutschy, Kristopher ;
Harrison, Daniel ;
Inzinna, Lou ;
Longtin, Randy ;
Neculaes, Bogdan ;
Reynolds, Joseph ;
Roy, Jaydeep ;
Short, Jonathan ;
Uribe, Jorge ;
Waters, William ;
Yin, Zhye ;
Zhang, Xi ;
Zou, Yun ;
Senzig, Bob ;
Baek, Jongduk ;
Pelc, Norbert .
2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, :3531-+